Impact of structural variables on hydroenergetic efficientization of water pumping system

Detalhes bibliográficos
Autor(a) principal: Silva, Alcione Batista da
Data de Publicação: 2020
Outros Autores: Pereira, José Almir Rodrigues, Almeida, Aline Christian Pimental
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/10553
Resumo: Evaluate the structural variables influence on the consumption and the electrical energy cost from Guamá river’s Water Pumping System (WPS) located in Belém city (Pará), through Plackett and Burman experimental planning, computational simulations and of statistical analysis. This present study was divided into four stages. In Step 1, it was carried out the design characterization and limits determination (minimum and maximum) of the variables geometric height, diameter and pressurized pipes length and stand pipe reservoir useful volume. Then (Step 2) it was applied the Plackett and Burman experimental planning, in order to define the number of tests to be simulated. In Step 3, it was held hydraulic simulations of different operational routines, to determine the consumption and electric power cost in the WPS. The last stage was accomplished statistical analysis (Hypothesis test and Pareto Diagram) for a 95% significance level. Based on the results, the structural variables that most impacted upon the consumption and the WPS electricity cost Guamá River were the useful volume daily required, followed by the pressurized pipe diameter. From the experimental planning technique application, the sanitation manager will be able to prioritize the energy efficiency actions of the investigated system.
id UNIFEI_fa454d9a8dd348cb30d9a2c19f84a2d1
oai_identifier_str oai:ojs.pkp.sfu.ca:article/10553
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Impact of structural variables on hydroenergetic efficientization of water pumping systemImpacto de las variables estructurales en la eficientización hidroenergética del sistema de bombeo de aguaImpacto das variáveis estruturais na eficientização hidroenergética de sistema de bombeamento de água Planificación experimentalEficiencia energeticaSistema de bombeo de aguaSimulación computacional.Experimental planningEnergy efficiencyWater pumping systemComputational simulation.Planejamento experimentalEficiência energéticaSistema de bombeamento de águaSimulação computacional.Evaluate the structural variables influence on the consumption and the electrical energy cost from Guamá river’s Water Pumping System (WPS) located in Belém city (Pará), through Plackett and Burman experimental planning, computational simulations and of statistical analysis. This present study was divided into four stages. In Step 1, it was carried out the design characterization and limits determination (minimum and maximum) of the variables geometric height, diameter and pressurized pipes length and stand pipe reservoir useful volume. Then (Step 2) it was applied the Plackett and Burman experimental planning, in order to define the number of tests to be simulated. In Step 3, it was held hydraulic simulations of different operational routines, to determine the consumption and electric power cost in the WPS. The last stage was accomplished statistical analysis (Hypothesis test and Pareto Diagram) for a 95% significance level. Based on the results, the structural variables that most impacted upon the consumption and the WPS electricity cost Guamá River were the useful volume daily required, followed by the pressurized pipe diameter. From the experimental planning technique application, the sanitation manager will be able to prioritize the energy efficiency actions of the investigated system.Evaluar la influencia de variables estructurales en el consumo y costo de electricidad del Sistema de Bombeo de Agua del Río Guamá ubicado en la ciudad de Belém do Pará, utilizando técnicas de planificación experimental de Plackett y Burman, simulaciones por computadora y análisis estadístico. Esta investigación se dividió en cuatro etapas. En el Paso 1 se realizó la caracterización del diseño y determinación de los límites (mínimo y máximo) de las variables altura geométrica, diámetro y longitud de las tuberías de descarga y volumen útil del reservorio elevado. Luego (Paso 2) se aplicó el diseño experimental de Plackett y Burman, con el propósito de definir el número de pruebas a simular. En el Paso 3, se realizaron simulaciones hidráulicas de diferentes rutinas operativas para determinar el consumo y costo de la electricidad en la SBA. En la última etapa se realizaron análisis estadísticos (Prueba de hipótesis y diagrama de Pareto), con un nivel de significancia del 95%. Con base en los resultados, las variables estructurales que más impactaron el consumo y costo de la electricidad en la SBA Río Guamá fueron el volumen útil diario requerido, seguido del diámetro de la tubería de descarga. A partir de la aplicación de la técnica de planificación experimental, el responsable de saneamiento podrá priorizar las acciones de eficiencia energética del sistema investigado.Avaliar a influência das variáveis estruturais sobre o consumo e o custo de energia elétrica do Sistema de Bombeamento de Água do Rio Guamá localizado na cidade de Belém do Pará, por meio de técnica de planejamento de experimentos de Plackett e Burman, de simulações computacionais e de análises estatísticas. A presente pesquisa foi dividida em quatro etapas. Na Etapa 1 foi realizada a caracterização da concepção e determinação dos limites (mínimo e máximo) das variáveis altura geométrica, diâmetro e comprimento das tubulações de recalque e volume útil do reservatório elevado. Em seguida (Etapa 2) foi aplicado o planejamento experimental de Plackett e Burman, com a finalidade de definir o número de ensaios a serem simulados. Na Etapa 3 foram realizadas a simulações hidráulicas de diferentes rotinas operacionais, para determinação do consumo e do custo de energia elétrica no SBA. Na última etapa foram realizadas análises estatísticas (Teste de hipótese e Diagrama de Pareto), para nível de significância de 95%. Com base nos resultados as variáveis estruturais que mais impactaram sobre o consumo e o custo de energia elétrica do SBA Rio Guamá foram o volume útil requerido diariamente, seguido do diâmetro da tubulação de recalque. A partir da aplicação da técnica de planejamento experimental o gestor de saneamento poderá priorizar as ações de eficiência energética do sistema investigado.Research, Society and Development2020-12-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1055310.33448/rsd-v9i11.10553Research, Society and Development; Vol. 9 No. 11; e93591110553Research, Society and Development; Vol. 9 Núm. 11; e93591110553Research, Society and Development; v. 9 n. 11; e935911105532525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/10553/9514Copyright (c) 2020 Alcione Batista da Silva; José Almir Rodrigues Pereira; Aline Christian Pimental Almeidahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessSilva, Alcione Batista daPereira, José Almir Rodrigues Almeida, Aline Christian Pimental 2020-12-10T23:37:57Zoai:ojs.pkp.sfu.ca:article/10553Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:32:36.073391Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Impact of structural variables on hydroenergetic efficientization of water pumping system
Impacto de las variables estructurales en la eficientización hidroenergética del sistema de bombeo de agua
Impacto das variáveis estruturais na eficientização hidroenergética de sistema de bombeamento de água
title Impact of structural variables on hydroenergetic efficientization of water pumping system
spellingShingle Impact of structural variables on hydroenergetic efficientization of water pumping system
Silva, Alcione Batista da
Planificación experimental
Eficiencia energetica
Sistema de bombeo de agua
Simulación computacional.
Experimental planning
Energy efficiency
Water pumping system
Computational simulation.
Planejamento experimental
Eficiência energética
Sistema de bombeamento de água
Simulação computacional.
title_short Impact of structural variables on hydroenergetic efficientization of water pumping system
title_full Impact of structural variables on hydroenergetic efficientization of water pumping system
title_fullStr Impact of structural variables on hydroenergetic efficientization of water pumping system
title_full_unstemmed Impact of structural variables on hydroenergetic efficientization of water pumping system
title_sort Impact of structural variables on hydroenergetic efficientization of water pumping system
author Silva, Alcione Batista da
author_facet Silva, Alcione Batista da
Pereira, José Almir Rodrigues
Almeida, Aline Christian Pimental
author_role author
author2 Pereira, José Almir Rodrigues
Almeida, Aline Christian Pimental
author2_role author
author
dc.contributor.author.fl_str_mv Silva, Alcione Batista da
Pereira, José Almir Rodrigues
Almeida, Aline Christian Pimental
dc.subject.por.fl_str_mv Planificación experimental
Eficiencia energetica
Sistema de bombeo de agua
Simulación computacional.
Experimental planning
Energy efficiency
Water pumping system
Computational simulation.
Planejamento experimental
Eficiência energética
Sistema de bombeamento de água
Simulação computacional.
topic Planificación experimental
Eficiencia energetica
Sistema de bombeo de agua
Simulación computacional.
Experimental planning
Energy efficiency
Water pumping system
Computational simulation.
Planejamento experimental
Eficiência energética
Sistema de bombeamento de água
Simulação computacional.
description Evaluate the structural variables influence on the consumption and the electrical energy cost from Guamá river’s Water Pumping System (WPS) located in Belém city (Pará), through Plackett and Burman experimental planning, computational simulations and of statistical analysis. This present study was divided into four stages. In Step 1, it was carried out the design characterization and limits determination (minimum and maximum) of the variables geometric height, diameter and pressurized pipes length and stand pipe reservoir useful volume. Then (Step 2) it was applied the Plackett and Burman experimental planning, in order to define the number of tests to be simulated. In Step 3, it was held hydraulic simulations of different operational routines, to determine the consumption and electric power cost in the WPS. The last stage was accomplished statistical analysis (Hypothesis test and Pareto Diagram) for a 95% significance level. Based on the results, the structural variables that most impacted upon the consumption and the WPS electricity cost Guamá River were the useful volume daily required, followed by the pressurized pipe diameter. From the experimental planning technique application, the sanitation manager will be able to prioritize the energy efficiency actions of the investigated system.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-08
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/10553
10.33448/rsd-v9i11.10553
url https://rsdjournal.org/index.php/rsd/article/view/10553
identifier_str_mv 10.33448/rsd-v9i11.10553
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/10553/9514
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 9 No. 11; e93591110553
Research, Society and Development; Vol. 9 Núm. 11; e93591110553
Research, Society and Development; v. 9 n. 11; e93591110553
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052665184649216