Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid

Detalhes bibliográficos
Autor(a) principal: Nunes, Osvaldo Benoni da Cunha
Data de Publicação: 2011
Outros Autores: Ramalho, Humberto de Sousa, Nunes, Nancy Alfieri, Abreu, Paulo Humaitá de
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista da Faculdade de Odontologia de Lins (Online)
Texto Completo: https://www.metodista.br/revistas/revistas-unimep/index.php/Fol/article/view/57
Resumo: The objective of this research was to verify the degree of marginal infiltration in class-V,  vestibular, and lingual cavities in 40 recently-extracted human premolar teeth, divided into four groups, which, after the thermal cycle at 5ºC/55ºC, and stained with 2% methylene blue, were assessed in two ways: 1 - types of composite resin: microparticles (Silux Plus - 3M), microhybrid (Z 250 - 3M) and nanohybrid (Grandio - VOCO); and 2 - location of the cavity wall (occlusal enamel wall and gingival cement wall). The data were measured through scores of 0 to 4 and statistically analyzed by nonparametric Kruskal-Wallis test in order to demonstrate the composite resin and cavity wall that allowed less dye leakage. The three types of composite resin - microparticles, microhybrid, and nanohybrid - showed no statistically significant difference between them; nanohybrid resin showed the lowest scores of dye penetration. There was no statistically significant difference between the occlusal enamel wall and the gingival cement wall. However, the occlusal enamel wall was the one with the lowest scores of dye penetration.
id UNIMEP_2c426daa6d4ffb2c7e27afc0acae65f4
oai_identifier_str oai:ojs-unimep.metodista.br:article/57
network_acronym_str UNIMEP
network_name_str Revista da Faculdade de Odontologia de Lins (Online)
repository_id_str
spelling Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybridInfiltração Marginal de Resinas Compostas: micropartícula, microhíbrida e nanohíbridainfiltração marginal; resinas compostas; nanopartículas..marginal infiltration; composite resin; nanoparticles.The objective of this research was to verify the degree of marginal infiltration in class-V,  vestibular, and lingual cavities in 40 recently-extracted human premolar teeth, divided into four groups, which, after the thermal cycle at 5ºC/55ºC, and stained with 2% methylene blue, were assessed in two ways: 1 - types of composite resin: microparticles (Silux Plus - 3M), microhybrid (Z 250 - 3M) and nanohybrid (Grandio - VOCO); and 2 - location of the cavity wall (occlusal enamel wall and gingival cement wall). The data were measured through scores of 0 to 4 and statistically analyzed by nonparametric Kruskal-Wallis test in order to demonstrate the composite resin and cavity wall that allowed less dye leakage. The three types of composite resin - microparticles, microhybrid, and nanohybrid - showed no statistically significant difference between them; nanohybrid resin showed the lowest scores of dye penetration. There was no statistically significant difference between the occlusal enamel wall and the gingival cement wall. However, the occlusal enamel wall was the one with the lowest scores of dye penetration.O objetivo desta pesquisa foi verificar o grau de infiltração marginal em cavidades classe V, vestibular e lingual, em 40 dentes pré-molares humanos extraídos e divididos em quatro grupos, os quais, após ciclagem térmica a 5ºC/55ºC e corados com o azul de metileno a 2%, foram avaliados sob dois aspectos: 1 – tipos de resina composta: micropartícula (Silux Plus – 3M), microhíbrida (Z 250 – 3M) e nanohíbrida (Grandio – VOCO); e 2 – localização da parede cavitária (parede oclusal em esmalte e parede gengival em cemento). Os dados foram mensurados por meio de escores de 0 a 4 e processados estatisticamente pelo teste não paramétrico de Kruskal-Wallis, a fim de demonstrar a resina composta e a parede cavitária que menos permitiu a infiltração do corante. Os três tipos de resina composta – micropartícula, microhíbrida e nanohíbrida – não mostraram diferença estatística significante entre si; a resina nanohíbrida foi a que apresentou os menores escores de infiltração do corante. Também não houve diferença estatística significante entre a parede oclusal em esmalte e gengival em cemento; todavia, a parede oclusal em esmalte foi a que apresentou os menores escores de infiltração do corante.Universidade Metodista de PiracicabaNunes, Osvaldo Benoni da CunhaRamalho, Humberto de SousaNunes, Nancy AlfieriAbreu, Paulo Humaitá de2011-02-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.metodista.br/revistas/revistas-unimep/index.php/Fol/article/view/5710.15600/2238-1236/fol.v21n1p25-38Revista da Faculdade de Odontologia de Lins; v. 21, n. 1 (2009): Revista da Faculdade de Odontologia de Lins; 25-382238-123601047582reponame:Revista da Faculdade de Odontologia de Lins (Online)instname:Universidade Metodista de Piracicaba (UNIMEP)instacron:UNIMEPporhttps://www.metodista.br/revistas/revistas-unimep/index.php/Fol/article/view/57/22info:eu-repo/semantics/openAccess2016-06-01T13:27:27Zoai:ojs-unimep.metodista.br:article/57Revistahttps://www.metodista.br/revistas/revistas-unimep/index.php/Folhttps://www.metodista.br/revistas/revistas-unimep/index.php/Fol/oai||revistafol@unimep.br|| nalfieri@unimep.br2238-12360104-7582opendoar:2016-06-01T13:27:27Revista da Faculdade de Odontologia de Lins (Online) - Universidade Metodista de Piracicaba (UNIMEP)false
dc.title.none.fl_str_mv Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
Infiltração Marginal de Resinas Compostas: micropartícula, microhíbrida e nanohíbrida
title Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
spellingShingle Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
Nunes, Osvaldo Benoni da Cunha
infiltração marginal; resinas compostas; nanopartículas..
marginal infiltration; composite resin; nanoparticles.
title_short Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
title_full Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
title_fullStr Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
title_full_unstemmed Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
title_sort Marginal Leakage of Composite Resins: microparticles, microhybrid and nanohybrid
author Nunes, Osvaldo Benoni da Cunha
author_facet Nunes, Osvaldo Benoni da Cunha
Ramalho, Humberto de Sousa
Nunes, Nancy Alfieri
Abreu, Paulo Humaitá de
author_role author
author2 Ramalho, Humberto de Sousa
Nunes, Nancy Alfieri
Abreu, Paulo Humaitá de
author2_role author
author
author
dc.contributor.none.fl_str_mv

dc.contributor.author.fl_str_mv Nunes, Osvaldo Benoni da Cunha
Ramalho, Humberto de Sousa
Nunes, Nancy Alfieri
Abreu, Paulo Humaitá de
dc.subject.none.fl_str_mv
dc.subject.por.fl_str_mv infiltração marginal; resinas compostas; nanopartículas..
marginal infiltration; composite resin; nanoparticles.
topic infiltração marginal; resinas compostas; nanopartículas..
marginal infiltration; composite resin; nanoparticles.
description The objective of this research was to verify the degree of marginal infiltration in class-V,  vestibular, and lingual cavities in 40 recently-extracted human premolar teeth, divided into four groups, which, after the thermal cycle at 5ºC/55ºC, and stained with 2% methylene blue, were assessed in two ways: 1 - types of composite resin: microparticles (Silux Plus - 3M), microhybrid (Z 250 - 3M) and nanohybrid (Grandio - VOCO); and 2 - location of the cavity wall (occlusal enamel wall and gingival cement wall). The data were measured through scores of 0 to 4 and statistically analyzed by nonparametric Kruskal-Wallis test in order to demonstrate the composite resin and cavity wall that allowed less dye leakage. The three types of composite resin - microparticles, microhybrid, and nanohybrid - showed no statistically significant difference between them; nanohybrid resin showed the lowest scores of dye penetration. There was no statistically significant difference between the occlusal enamel wall and the gingival cement wall. However, the occlusal enamel wall was the one with the lowest scores of dye penetration.
publishDate 2011
dc.date.none.fl_str_mv 2011-02-11
dc.type.none.fl_str_mv
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.metodista.br/revistas/revistas-unimep/index.php/Fol/article/view/57
10.15600/2238-1236/fol.v21n1p25-38
url https://www.metodista.br/revistas/revistas-unimep/index.php/Fol/article/view/57
identifier_str_mv 10.15600/2238-1236/fol.v21n1p25-38
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://www.metodista.br/revistas/revistas-unimep/index.php/Fol/article/view/57/22
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Metodista de Piracicaba
publisher.none.fl_str_mv Universidade Metodista de Piracicaba
dc.source.none.fl_str_mv Revista da Faculdade de Odontologia de Lins; v. 21, n. 1 (2009): Revista da Faculdade de Odontologia de Lins; 25-38
2238-1236
01047582
reponame:Revista da Faculdade de Odontologia de Lins (Online)
instname:Universidade Metodista de Piracicaba (UNIMEP)
instacron:UNIMEP
instname_str Universidade Metodista de Piracicaba (UNIMEP)
instacron_str UNIMEP
institution UNIMEP
reponame_str Revista da Faculdade de Odontologia de Lins (Online)
collection Revista da Faculdade de Odontologia de Lins (Online)
repository.name.fl_str_mv Revista da Faculdade de Odontologia de Lins (Online) - Universidade Metodista de Piracicaba (UNIMEP)
repository.mail.fl_str_mv ||revistafol@unimep.br|| nalfieri@unimep.br
_version_ 1754569015653564416