EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS

Detalhes bibliográficos
Autor(a) principal: Albarado, Marineuza
Data de Publicação: 2020
Outros Autores: Figueira, Geovani Waghan, Albarado, Kaio Vinícius, da Silva, Paula Luane, Saatkamp, Jamille, de Almeida, Mauricio Liberal
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Uningá (Online)
Texto Completo: https://revista.uninga.br/uninga/article/view/2909
Resumo: Quality assurance is the tool that enables the clinical analysis laboratory to provide reliable, appropriately and correctly interpreted results. Calibrators are used in the routine of these laboratories, which are known standards with determinated quantitative and / or qualitative characteristics used to calibrate, calibrate, or adjust a measurement procedure. Control are used for multiparameter calibration at the same time and should be used in accordance with manufacturer's recommendations. Calibrator performance may be affected by reconstitution, homogenization, improper storage, water contamination, or glassmaking errors. Thus, this work evaluated the stability of commercial control submitted to different temperatures in real laboratory situations, such as refrigeration between 4-8 ºC, exposure under a working bench, at room temperature, and stored inside a car, at temperatures of 60-80 ºC, for periods of 1 to 12 days. Both the time and the temperature at which the aliquots are stored did not cause changes in this product (except for creatinine, which was unstable on the 12th day of the study), presenting values within the estimated ranges, and possibly the aliquots outside the estimated ranges follow a systematic error.
id UNINGA-1_4d7369e83be6028acefa76c2b73dc633
oai_identifier_str oai:ojs.revista.uninga.br:article/2909
network_acronym_str UNINGA-1
network_name_str Revista Uningá (Online)
repository_id_str
spelling EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONSAVALIAÇÃO DA ESTABILIDADE DE CONTROLES PARA ANÁLISES DE DIAGNÓSTICO IN VITRO EM CONDIÇÕES DE TEMPERATURA REAIS DE TRABALHO LABORATORIALControleControle de QualidadeDiagnóstico in vitroControlIn vitro diagnosisQuality ControlQuality assurance is the tool that enables the clinical analysis laboratory to provide reliable, appropriately and correctly interpreted results. Calibrators are used in the routine of these laboratories, which are known standards with determinated quantitative and / or qualitative characteristics used to calibrate, calibrate, or adjust a measurement procedure. Control are used for multiparameter calibration at the same time and should be used in accordance with manufacturer's recommendations. Calibrator performance may be affected by reconstitution, homogenization, improper storage, water contamination, or glassmaking errors. Thus, this work evaluated the stability of commercial control submitted to different temperatures in real laboratory situations, such as refrigeration between 4-8 ºC, exposure under a working bench, at room temperature, and stored inside a car, at temperatures of 60-80 ºC, for periods of 1 to 12 days. Both the time and the temperature at which the aliquots are stored did not cause changes in this product (except for creatinine, which was unstable on the 12th day of the study), presenting values within the estimated ranges, and possibly the aliquots outside the estimated ranges follow a systematic error.A garantia da qualidade é o mecanismo que propicia ao laboratório de análises clínicas apresentar resultados confiáveis adequados e corretamente interpretados. Na rotina de trabalho desses laboratórios, utilizam-se calibradores, que são padrões conhecidos com características quantitativas e/ou qualitativas determinadas, os controles podem ser utilizados para medir alguns parâmetros de qualidade laboratorial. A depender dos fabricantes, existem algumas sugestões de manuseio a ser seguido, para então, obter maior fidedignidade de aferição. O desempenho do calibrador pode ser afetado por erros de reconstituição, de homogeneização, armazenamento incorreto, contaminação da água ou vidraria. Dessa forma, este trabalho avaliou a estabilidade de controles comerciais submetidos a temperaturas diversas encontradas em situações reais de laboratório, como a refrigeração entre 4-8 ºC, exposição sob bancada de trabalho, a temperatura ambiente, e armazenada dentro de um automóvel, em temperaturas de 60-80 ºC, por períodos de 1 a 12 dias. Tanto o tempo quanto a temperatura em que as alíquotas são armazenadas não ocasionaram alterações nesse produto (exceto para a creatinina, apresentou-se instável no 12º dia do estudo), apresentando valores dentro das faixas estimadas, e possivelmente as alíquotas fora das faixas estimadas devem-se a erro sistemático.Editora Uningá2020-12-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontextoapplication/pdfhttps://revista.uninga.br/uninga/article/view/290910.46311/2318-0579.57.eUJ2909Revista Uningá; Vol. 57 No. 4 (2020): Revista UNINGÁ; 9-22Revista Uningá; v. 57 n. 4 (2020): Revista UNINGÁ; 9-222318-057910.46311/ru.v57i4reponame:Revista Uningá (Online)instname:Centro Universitário Uningáinstacron:UNINGAporhttps://revista.uninga.br/uninga/article/view/2909/224910.46311/ru.v57i4.2909.g2249Copyright (c) 2020 UNINGÁ JOURNALinfo:eu-repo/semantics/openAccessAlbarado, MarineuzaFigueira, Geovani WaghanAlbarado, Kaio Viníciusda Silva, Paula LuaneSaatkamp, Jamillede Almeida, Mauricio Liberal2020-12-23T20:11:56Zoai:ojs.revista.uninga.br:article/2909Revistahttps://revista.uninga.br/uninga/indexPUBhttps://revista.uninga.br/uninga/oairevistauninga@uninga.edu.br2318-05792318-0579opendoar:2020-12-23T20:11:56Revista Uningá (Online) - Centro Universitário Uningáfalse
dc.title.none.fl_str_mv EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
AVALIAÇÃO DA ESTABILIDADE DE CONTROLES PARA ANÁLISES DE DIAGNÓSTICO IN VITRO EM CONDIÇÕES DE TEMPERATURA REAIS DE TRABALHO LABORATORIAL
title EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
spellingShingle EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
Albarado, Marineuza
Controle
Controle de Qualidade
Diagnóstico in vitro
Control
In vitro diagnosis
Quality Control
title_short EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
title_full EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
title_fullStr EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
title_full_unstemmed EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
title_sort EVALUATION OF THE STABILITY OF CONTROL FOR IN VITRO DIAGNOSTIC ANALYZES UNDER REAL LABOR LABORATORY TEMPERATURE CONDITIONS
author Albarado, Marineuza
author_facet Albarado, Marineuza
Figueira, Geovani Waghan
Albarado, Kaio Vinícius
da Silva, Paula Luane
Saatkamp, Jamille
de Almeida, Mauricio Liberal
author_role author
author2 Figueira, Geovani Waghan
Albarado, Kaio Vinícius
da Silva, Paula Luane
Saatkamp, Jamille
de Almeida, Mauricio Liberal
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Albarado, Marineuza
Figueira, Geovani Waghan
Albarado, Kaio Vinícius
da Silva, Paula Luane
Saatkamp, Jamille
de Almeida, Mauricio Liberal
dc.subject.por.fl_str_mv Controle
Controle de Qualidade
Diagnóstico in vitro
Control
In vitro diagnosis
Quality Control
topic Controle
Controle de Qualidade
Diagnóstico in vitro
Control
In vitro diagnosis
Quality Control
description Quality assurance is the tool that enables the clinical analysis laboratory to provide reliable, appropriately and correctly interpreted results. Calibrators are used in the routine of these laboratories, which are known standards with determinated quantitative and / or qualitative characteristics used to calibrate, calibrate, or adjust a measurement procedure. Control are used for multiparameter calibration at the same time and should be used in accordance with manufacturer's recommendations. Calibrator performance may be affected by reconstitution, homogenization, improper storage, water contamination, or glassmaking errors. Thus, this work evaluated the stability of commercial control submitted to different temperatures in real laboratory situations, such as refrigeration between 4-8 ºC, exposure under a working bench, at room temperature, and stored inside a car, at temperatures of 60-80 ºC, for periods of 1 to 12 days. Both the time and the temperature at which the aliquots are stored did not cause changes in this product (except for creatinine, which was unstable on the 12th day of the study), presenting values within the estimated ranges, and possibly the aliquots outside the estimated ranges follow a systematic error.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-23
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
texto
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revista.uninga.br/uninga/article/view/2909
10.46311/2318-0579.57.eUJ2909
url https://revista.uninga.br/uninga/article/view/2909
identifier_str_mv 10.46311/2318-0579.57.eUJ2909
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://revista.uninga.br/uninga/article/view/2909/2249
10.46311/ru.v57i4.2909.g2249
dc.rights.driver.fl_str_mv Copyright (c) 2020 UNINGÁ JOURNAL
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 UNINGÁ JOURNAL
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Editora Uningá
publisher.none.fl_str_mv Editora Uningá
dc.source.none.fl_str_mv Revista Uningá; Vol. 57 No. 4 (2020): Revista UNINGÁ; 9-22
Revista Uningá; v. 57 n. 4 (2020): Revista UNINGÁ; 9-22
2318-0579
10.46311/ru.v57i4
reponame:Revista Uningá (Online)
instname:Centro Universitário Uningá
instacron:UNINGA
instname_str Centro Universitário Uningá
instacron_str UNINGA
institution UNINGA
reponame_str Revista Uningá (Online)
collection Revista Uningá (Online)
repository.name.fl_str_mv Revista Uningá (Online) - Centro Universitário Uningá
repository.mail.fl_str_mv revistauninga@uninga.edu.br
_version_ 1797042165977710592