COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | por eng |
Título da fonte: | Revista Uningá (Online) |
Texto Completo: | https://revista.uninga.br/uninga/article/view/3539 |
Resumo: | This in vitro study aimed to measure the influence of colors on the force degradation of orthodontic power chain of the Morelli® brand, after stretched and submerged in artificial saliva. The values were obtained after immediate measurement (time zero), 0.5, 1 and 24 hours of immersion. Twenty samples were selected at random from each of the colors of elastomeric chain. Each sample, composed of 4 links, was initially pre-stretched, with two probes, until stress. The determination of the amount of stretch of the elastics for measurement corresponds to 50% of the value of the initial pre-stretch. After the initial reading, each sample was removed from the dynamometer with the aid of a clinical tweezers and then placed on a device (template with pins) developed to accommodate the rubber bands. The sets (device + samples) were immersed in artificial saliva at 37± 1 °C (hysteresis). In the time intervals 30 minutes, 1 hour and 24 hours. The samples at time zero showed significant differences (p <0.05) between colors, with greater variation for gray and lesser for black. All colors showed greater force degradation in the first hour. |
id |
UNINGA-1_efa26f870d4d9f629d2988809a625f96 |
---|---|
oai_identifier_str |
oai:ojs.revista.uninga.br:article/3539 |
network_acronym_str |
UNINGA-1 |
network_name_str |
Revista Uningá (Online) |
repository_id_str |
|
spelling |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDYESTUDO COMPARATIVO ENTRE DIFERENTES CORES DE ELÁSTICOS EM CADEIA SINTÉTICOS: IN VITROCorElasticidadeElastômerosOrtodontiaElásticos OrtodônticosColorElasticityElastomersOrthodonticsThis in vitro study aimed to measure the influence of colors on the force degradation of orthodontic power chain of the Morelli® brand, after stretched and submerged in artificial saliva. The values were obtained after immediate measurement (time zero), 0.5, 1 and 24 hours of immersion. Twenty samples were selected at random from each of the colors of elastomeric chain. Each sample, composed of 4 links, was initially pre-stretched, with two probes, until stress. The determination of the amount of stretch of the elastics for measurement corresponds to 50% of the value of the initial pre-stretch. After the initial reading, each sample was removed from the dynamometer with the aid of a clinical tweezers and then placed on a device (template with pins) developed to accommodate the rubber bands. The sets (device + samples) were immersed in artificial saliva at 37± 1 °C (hysteresis). In the time intervals 30 minutes, 1 hour and 24 hours. The samples at time zero showed significant differences (p <0.05) between colors, with greater variation for gray and lesser for black. All colors showed greater force degradation in the first hour.Este estudo, in vitro, teve como meta medir a influência das cores sobre a degradação da força de elásticos ortodônticos em cadeia da marca Morelli®, após estirados e submersos em saliva artificial. Os valores foram obtidos após mensuração imediata (tempo zero), 30 minutos, 1 hora e 24 horas de submersão. Foram analisadas vinte amostras, escolhidas aleatoriamente, de cada uma das cores de elásticos em cadeia sintéticos. Cada amostra, composta por 4 elos, foi inicialmente pré-estiradas, com o auxílio de duas sondas exploradoras, até o estresse. A determinação da quantidade de estiramento dos elásticos para aferição corresponde a 50% do valor do pré-estiramento inicial. Após a leitura inicial, cada um dos elásticos foi retirado do dinamômetro com o auxílio de uma pinça clínica e em seguida assentados sobre um gabarito com pinos desenvolvidos para acomodação dos elásticos. Os conjuntos (gabarito + elásticos) foram imersos em saliva artificial a 37 °C (histerese ± 1°). Nos intervalos de tempo 30 minutos, 1 hora e 24 horas. As amostras no tempo zero apresentavam diferenças significativas (p<0,05) entre as cores, com maior variação para a cinza e menor para a cor preta. Todas as cores mostraram maior degradação de força na primeira hora.Editora Uningá2020-12-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTextoapplication/pdfapplication/pdfhttps://revista.uninga.br/uninga/article/view/353910.46311/2318-0579.57.eUJ3539Revista Uningá; Vol. 57 No. 4 (2020): Revista UNINGÁ; 57-66Revista Uningá; v. 57 n. 4 (2020): Revista UNINGÁ; 57-662318-057910.46311/ru.v57i4reponame:Revista Uningá (Online)instname:Centro Universitário Uningáinstacron:UNINGAporenghttps://revista.uninga.br/uninga/article/view/3539/2253https://revista.uninga.br/uninga/article/view/3539/225410.46311/ru.v57i4.3539.g225310.46311/ru.v57i4.3539.g2254Copyright (c) 2020 UNINGÁ JOURNALhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessCigognini, Géssica ZamboniMarkoski, KarolineKarch, MatheusGiovanetti, Marcosda Silva, Simone Camargo2022-09-16T19:39:16Zoai:ojs.revista.uninga.br:article/3539Revistahttps://revista.uninga.br/uninga/indexPUBhttps://revista.uninga.br/uninga/oairevistauninga@uninga.edu.br2318-05792318-0579opendoar:2022-09-16T19:39:16Revista Uningá (Online) - Centro Universitário Uningáfalse |
dc.title.none.fl_str_mv |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY ESTUDO COMPARATIVO ENTRE DIFERENTES CORES DE ELÁSTICOS EM CADEIA SINTÉTICOS: IN VITRO |
title |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY |
spellingShingle |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY Cigognini, Géssica Zamboni Cor Elasticidade Elastômeros Ortodontia Elásticos Ortodônticos Color Elasticity Elastomers Orthodontics |
title_short |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY |
title_full |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY |
title_fullStr |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY |
title_full_unstemmed |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY |
title_sort |
COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY |
author |
Cigognini, Géssica Zamboni |
author_facet |
Cigognini, Géssica Zamboni Markoski, Karoline Karch, Matheus Giovanetti, Marcos da Silva, Simone Camargo |
author_role |
author |
author2 |
Markoski, Karoline Karch, Matheus Giovanetti, Marcos da Silva, Simone Camargo |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Cigognini, Géssica Zamboni Markoski, Karoline Karch, Matheus Giovanetti, Marcos da Silva, Simone Camargo |
dc.subject.por.fl_str_mv |
Cor Elasticidade Elastômeros Ortodontia Elásticos Ortodônticos Color Elasticity Elastomers Orthodontics |
topic |
Cor Elasticidade Elastômeros Ortodontia Elásticos Ortodônticos Color Elasticity Elastomers Orthodontics |
description |
This in vitro study aimed to measure the influence of colors on the force degradation of orthodontic power chain of the Morelli® brand, after stretched and submerged in artificial saliva. The values were obtained after immediate measurement (time zero), 0.5, 1 and 24 hours of immersion. Twenty samples were selected at random from each of the colors of elastomeric chain. Each sample, composed of 4 links, was initially pre-stretched, with two probes, until stress. The determination of the amount of stretch of the elastics for measurement corresponds to 50% of the value of the initial pre-stretch. After the initial reading, each sample was removed from the dynamometer with the aid of a clinical tweezers and then placed on a device (template with pins) developed to accommodate the rubber bands. The sets (device + samples) were immersed in artificial saliva at 37± 1 °C (hysteresis). In the time intervals 30 minutes, 1 hour and 24 hours. The samples at time zero showed significant differences (p <0.05) between colors, with greater variation for gray and lesser for black. All colors showed greater force degradation in the first hour. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-23 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Texto |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revista.uninga.br/uninga/article/view/3539 10.46311/2318-0579.57.eUJ3539 |
url |
https://revista.uninga.br/uninga/article/view/3539 |
identifier_str_mv |
10.46311/2318-0579.57.eUJ3539 |
dc.language.iso.fl_str_mv |
por eng |
language |
por eng |
dc.relation.none.fl_str_mv |
https://revista.uninga.br/uninga/article/view/3539/2253 https://revista.uninga.br/uninga/article/view/3539/2254 10.46311/ru.v57i4.3539.g2253 10.46311/ru.v57i4.3539.g2254 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2020 UNINGÁ JOURNAL https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2020 UNINGÁ JOURNAL https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Editora Uningá |
publisher.none.fl_str_mv |
Editora Uningá |
dc.source.none.fl_str_mv |
Revista Uningá; Vol. 57 No. 4 (2020): Revista UNINGÁ; 57-66 Revista Uningá; v. 57 n. 4 (2020): Revista UNINGÁ; 57-66 2318-0579 10.46311/ru.v57i4 reponame:Revista Uningá (Online) instname:Centro Universitário Uningá instacron:UNINGA |
instname_str |
Centro Universitário Uningá |
instacron_str |
UNINGA |
institution |
UNINGA |
reponame_str |
Revista Uningá (Online) |
collection |
Revista Uningá (Online) |
repository.name.fl_str_mv |
Revista Uningá (Online) - Centro Universitário Uningá |
repository.mail.fl_str_mv |
revistauninga@uninga.edu.br |
_version_ |
1797042166125559808 |