COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY

Detalhes bibliográficos
Autor(a) principal: Cigognini, Géssica Zamboni
Data de Publicação: 2020
Outros Autores: Markoski, Karoline, Karch, Matheus, Giovanetti, Marcos, da Silva, Simone Camargo
Tipo de documento: Artigo
Idioma: por
eng
Título da fonte: Revista Uningá (Online)
Texto Completo: https://revista.uninga.br/uninga/article/view/3539
Resumo: This in vitro study aimed to measure the influence of colors on the force degradation of orthodontic power chain of the Morelli® brand, after stretched and submerged in artificial saliva. The values were obtained after immediate measurement (time zero), 0.5, 1 and 24 hours of immersion. Twenty samples were selected at random from each of the colors of elastomeric chain. Each sample, composed of 4 links, was initially pre-stretched, with two probes, until stress. The determination of the amount of stretch of the elastics for measurement corresponds to 50% of the value of the initial pre-stretch. After the initial reading, each sample was removed from the dynamometer with the aid of a clinical tweezers and then placed on a device (template with pins) developed to accommodate the rubber bands. The sets (device + samples) were immersed in artificial saliva at 37± 1 °C (hysteresis). In the time intervals 30 minutes, 1 hour and 24 hours. The samples at time zero showed significant differences (p <0.05) between colors, with greater variation for gray and lesser for black. All colors showed greater force degradation in the first hour.
id UNINGA-1_efa26f870d4d9f629d2988809a625f96
oai_identifier_str oai:ojs.revista.uninga.br:article/3539
network_acronym_str UNINGA-1
network_name_str Revista Uningá (Online)
repository_id_str
spelling COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDYESTUDO COMPARATIVO ENTRE DIFERENTES CORES DE ELÁSTICOS EM CADEIA SINTÉTICOS: IN VITROCorElasticidadeElastômerosOrtodontiaElásticos OrtodônticosColorElasticityElastomersOrthodonticsThis in vitro study aimed to measure the influence of colors on the force degradation of orthodontic power chain of the Morelli® brand, after stretched and submerged in artificial saliva. The values were obtained after immediate measurement (time zero), 0.5, 1 and 24 hours of immersion. Twenty samples were selected at random from each of the colors of elastomeric chain. Each sample, composed of 4 links, was initially pre-stretched, with two probes, until stress. The determination of the amount of stretch of the elastics for measurement corresponds to 50% of the value of the initial pre-stretch. After the initial reading, each sample was removed from the dynamometer with the aid of a clinical tweezers and then placed on a device (template with pins) developed to accommodate the rubber bands. The sets (device + samples) were immersed in artificial saliva at 37± 1 °C (hysteresis). In the time intervals 30 minutes, 1 hour and 24 hours. The samples at time zero showed significant differences (p <0.05) between colors, with greater variation for gray and lesser for black. All colors showed greater force degradation in the first hour.Este estudo, in vitro, teve como meta medir a influência das cores sobre a degradação da força de elásticos ortodônticos em cadeia da marca Morelli®, após estirados e submersos em saliva artificial. Os valores foram obtidos após mensuração imediata (tempo zero), 30 minutos, 1 hora e 24 horas de submersão. Foram analisadas vinte amostras, escolhidas aleatoriamente, de cada uma das cores de elásticos em cadeia sintéticos. Cada amostra, composta por 4 elos, foi inicialmente pré-estiradas, com o auxílio de duas sondas exploradoras, até o estresse. A determinação da quantidade de estiramento dos elásticos para aferição corresponde a 50% do valor do pré-estiramento inicial. Após a leitura inicial, cada um dos elásticos foi retirado do dinamômetro com o auxílio de uma pinça clínica e em seguida assentados sobre um gabarito com pinos desenvolvidos para acomodação dos elásticos. Os conjuntos (gabarito + elásticos) foram imersos em saliva artificial a 37 °C (histerese ± 1°). Nos intervalos de tempo 30 minutos, 1 hora e 24 horas. As amostras no tempo zero apresentavam diferenças significativas (p<0,05) entre as cores, com maior variação para a cinza e menor para a cor preta. Todas as cores mostraram maior degradação de força na primeira hora.Editora Uningá2020-12-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTextoapplication/pdfapplication/pdfhttps://revista.uninga.br/uninga/article/view/353910.46311/2318-0579.57.eUJ3539Revista Uningá; Vol. 57 No. 4 (2020): Revista UNINGÁ; 57-66Revista Uningá; v. 57 n. 4 (2020): Revista UNINGÁ; 57-662318-057910.46311/ru.v57i4reponame:Revista Uningá (Online)instname:Centro Universitário Uningáinstacron:UNINGAporenghttps://revista.uninga.br/uninga/article/view/3539/2253https://revista.uninga.br/uninga/article/view/3539/225410.46311/ru.v57i4.3539.g225310.46311/ru.v57i4.3539.g2254Copyright (c) 2020 UNINGÁ JOURNALhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessCigognini, Géssica ZamboniMarkoski, KarolineKarch, MatheusGiovanetti, Marcosda Silva, Simone Camargo2022-09-16T19:39:16Zoai:ojs.revista.uninga.br:article/3539Revistahttps://revista.uninga.br/uninga/indexPUBhttps://revista.uninga.br/uninga/oairevistauninga@uninga.edu.br2318-05792318-0579opendoar:2022-09-16T19:39:16Revista Uningá (Online) - Centro Universitário Uningáfalse
dc.title.none.fl_str_mv COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
ESTUDO COMPARATIVO ENTRE DIFERENTES CORES DE ELÁSTICOS EM CADEIA SINTÉTICOS: IN VITRO
title COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
spellingShingle COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
Cigognini, Géssica Zamboni
Cor
Elasticidade
Elastômeros
Ortodontia
Elásticos Ortodônticos
Color
Elasticity
Elastomers
Orthodontics
title_short COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
title_full COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
title_fullStr COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
title_full_unstemmed COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
title_sort COMPARATIVE STUDY BETWEEN DIFFERENT COLORS OF ELASTOMERIC CHAIN: AN IN VITRO STUDY
author Cigognini, Géssica Zamboni
author_facet Cigognini, Géssica Zamboni
Markoski, Karoline
Karch, Matheus
Giovanetti, Marcos
da Silva, Simone Camargo
author_role author
author2 Markoski, Karoline
Karch, Matheus
Giovanetti, Marcos
da Silva, Simone Camargo
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Cigognini, Géssica Zamboni
Markoski, Karoline
Karch, Matheus
Giovanetti, Marcos
da Silva, Simone Camargo
dc.subject.por.fl_str_mv Cor
Elasticidade
Elastômeros
Ortodontia
Elásticos Ortodônticos
Color
Elasticity
Elastomers
Orthodontics
topic Cor
Elasticidade
Elastômeros
Ortodontia
Elásticos Ortodônticos
Color
Elasticity
Elastomers
Orthodontics
description This in vitro study aimed to measure the influence of colors on the force degradation of orthodontic power chain of the Morelli® brand, after stretched and submerged in artificial saliva. The values were obtained after immediate measurement (time zero), 0.5, 1 and 24 hours of immersion. Twenty samples were selected at random from each of the colors of elastomeric chain. Each sample, composed of 4 links, was initially pre-stretched, with two probes, until stress. The determination of the amount of stretch of the elastics for measurement corresponds to 50% of the value of the initial pre-stretch. After the initial reading, each sample was removed from the dynamometer with the aid of a clinical tweezers and then placed on a device (template with pins) developed to accommodate the rubber bands. The sets (device + samples) were immersed in artificial saliva at 37± 1 °C (hysteresis). In the time intervals 30 minutes, 1 hour and 24 hours. The samples at time zero showed significant differences (p <0.05) between colors, with greater variation for gray and lesser for black. All colors showed greater force degradation in the first hour.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-23
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Texto
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revista.uninga.br/uninga/article/view/3539
10.46311/2318-0579.57.eUJ3539
url https://revista.uninga.br/uninga/article/view/3539
identifier_str_mv 10.46311/2318-0579.57.eUJ3539
dc.language.iso.fl_str_mv por
eng
language por
eng
dc.relation.none.fl_str_mv https://revista.uninga.br/uninga/article/view/3539/2253
https://revista.uninga.br/uninga/article/view/3539/2254
10.46311/ru.v57i4.3539.g2253
10.46311/ru.v57i4.3539.g2254
dc.rights.driver.fl_str_mv Copyright (c) 2020 UNINGÁ JOURNAL
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 UNINGÁ JOURNAL
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Editora Uningá
publisher.none.fl_str_mv Editora Uningá
dc.source.none.fl_str_mv Revista Uningá; Vol. 57 No. 4 (2020): Revista UNINGÁ; 57-66
Revista Uningá; v. 57 n. 4 (2020): Revista UNINGÁ; 57-66
2318-0579
10.46311/ru.v57i4
reponame:Revista Uningá (Online)
instname:Centro Universitário Uningá
instacron:UNINGA
instname_str Centro Universitário Uningá
instacron_str UNINGA
institution UNINGA
reponame_str Revista Uningá (Online)
collection Revista Uningá (Online)
repository.name.fl_str_mv Revista Uningá (Online) - Centro Universitário Uningá
repository.mail.fl_str_mv revistauninga@uninga.edu.br
_version_ 1797042166125559808