Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais

Detalhes bibliográficos
Autor(a) principal: Santos, Joelmir dos
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações do UNIOESTE
Texto Completo: http://tede.unioeste.br/handle/tede/3571
Resumo: This study aimed the evaluation and application of methodology for multielement analyses by total reflection X-ray fluorescence spectrometry (TXRF) in order to provide analyte concentration measurements with accuracy and precision. Using the energy and intensity of the spectral lines of characteristic X-ray, a series of chemicals were identified and quantified, respectively, with a concentration below part per million to a few parts per billion, especially for transition metals. To ensure statistical reliability and reproducibility, a methodology based on the deposition of fine particles, less than 50 m, representative sample and uniformly spread on a quartz flat reflector, which was extremely clean and positioned at the angular condition of maximum reflectivity of monochromatic X-rays was applied. To ensure uniformity on the support surface and the sample representativeness, a number of replicas of specific quantities of samples, in the form of a fine powder was added in a diluted viscous organic solution containing a well-known concentration of an element choosing as internal standard. An aliquot of the viscous solution containing both the suspended particulate sample and an internal standard was deposited at the center of the quartz reflector and dried, yielding a very thin layer of particulates. First, the instrumental TXRF was previously evaluated for its operation, spectral response and recovery of transition metal concentrations in a test sample supplied by the manufacturer. The reproducibility of the elemental concentration measurements was tested with a combination of the number of experimental replicates (five) and analytical (three) for each type of environmental matrix samples, namely certified reference materials or CRMs. Six types of CRMs were tested: river sediment, tomato leaves, rice, fish muscle, bone and bovine liver. The data were statistically processed data, resulting in a series of average and uncertainty values of the analyte concentrations was compared to certified reference values, reported in the technical reports of CRM. Regarding the multielement character of the TXRF technique, there was a good recovery, about 100%, for most of the certified concentrations of the referenced analytes in the six CRMs within the margin of variability of results found by both the TXRF technique and reports. It was also found that the detection limit depends on the density matrix of the material under study. However, the transition elements were those with the lowest values of detection limits. Having a good recovery of majority analyte concentrations in Buffalo River sediment reference material, the same methodology was applied to sediment material analysis of Bezerra stream that was collected in three locations and for a period of three years. A number of chemicals has been identified through their spectral lines K and L and quantified following the internal standard method. The set of concentration data was statistically processed from the point of view of the normality of the data and an analysis of principal components, revealing a systematic presence of high concentrations of heavy metals such as lead and chromium, comparatively higher those recommended by current environmental legislation (CONAMA 420/2009) as the maximum permissible limits.
id UNIOESTE-1_98db4cc039db41836a7c067a8175df4d
oai_identifier_str oai:tede.unioeste.br:tede/3571
network_acronym_str UNIOESTE-1
network_name_str Biblioteca Digital de Teses e Dissertações do UNIOESTE
repository_id_str
spelling Espinoza Quiñones, Fernando Rodolfohttp://lattes.cnpq.br/7943425772967712Módenes, Aparecido Nivaldohttp://lattes.cnpq.br/7294940837327863Espinoza Quiñones, Fernando Rodolfohttp://lattes.cnpq.br/7943425772967712Dragunski, Douglas Cardosohttp://lattes.cnpq.br/0612112281360342Frigori, Rafael Bertolinihttp://lattes.cnpq.br/5836878566801544http://lattes.cnpq.br/5955061598962138Santos, Joelmir dos2018-04-25T00:28:56Z2016-02-29SANTOS, Joelmir dos. Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais. 2016. 138 f. Dissertação (Mestrado em Engenharia Química) - Universidade Estadual do Oeste do Paraná, Toledo, 2016.http://tede.unioeste.br/handle/tede/3571This study aimed the evaluation and application of methodology for multielement analyses by total reflection X-ray fluorescence spectrometry (TXRF) in order to provide analyte concentration measurements with accuracy and precision. Using the energy and intensity of the spectral lines of characteristic X-ray, a series of chemicals were identified and quantified, respectively, with a concentration below part per million to a few parts per billion, especially for transition metals. To ensure statistical reliability and reproducibility, a methodology based on the deposition of fine particles, less than 50 m, representative sample and uniformly spread on a quartz flat reflector, which was extremely clean and positioned at the angular condition of maximum reflectivity of monochromatic X-rays was applied. To ensure uniformity on the support surface and the sample representativeness, a number of replicas of specific quantities of samples, in the form of a fine powder was added in a diluted viscous organic solution containing a well-known concentration of an element choosing as internal standard. An aliquot of the viscous solution containing both the suspended particulate sample and an internal standard was deposited at the center of the quartz reflector and dried, yielding a very thin layer of particulates. First, the instrumental TXRF was previously evaluated for its operation, spectral response and recovery of transition metal concentrations in a test sample supplied by the manufacturer. The reproducibility of the elemental concentration measurements was tested with a combination of the number of experimental replicates (five) and analytical (three) for each type of environmental matrix samples, namely certified reference materials or CRMs. Six types of CRMs were tested: river sediment, tomato leaves, rice, fish muscle, bone and bovine liver. The data were statistically processed data, resulting in a series of average and uncertainty values of the analyte concentrations was compared to certified reference values, reported in the technical reports of CRM. Regarding the multielement character of the TXRF technique, there was a good recovery, about 100%, for most of the certified concentrations of the referenced analytes in the six CRMs within the margin of variability of results found by both the TXRF technique and reports. It was also found that the detection limit depends on the density matrix of the material under study. However, the transition elements were those with the lowest values of detection limits. Having a good recovery of majority analyte concentrations in Buffalo River sediment reference material, the same methodology was applied to sediment material analysis of Bezerra stream that was collected in three locations and for a period of three years. A number of chemicals has been identified through their spectral lines K and L and quantified following the internal standard method. The set of concentration data was statistically processed from the point of view of the normality of the data and an analysis of principal components, revealing a systematic presence of high concentrations of heavy metals such as lead and chromium, comparatively higher those recommended by current environmental legislation (CONAMA 420/2009) as the maximum permissible limits.Este trabalho teve como objetivo a avaliação e aplicação de metodologia para análise multielementar por meio da espectrometria de fluorescência de raios X por reflexão total (TXRF), a fim de fornecer medidas de concentração de analitos com acurácia e precisão. Usando a energia e a intensidade das linhas espectrais de raios X característicos, uma série de elementos químicos foram identificados e quantificados, respectivamente, com concentração abaixo de parte por milhão até poucas partes por bilhão, principalmente para metais de transição. A fim de garantir a confiabilidade e reprodutibilidade estatística, foi aplicada uma metodologia que se baseia na deposição de particulados finos, menores que 50 m, representativos da amostra e uniformemente distribuídos sobre um refletor plano de quartzo, previamente limpo, na condição angular de máxima refletividade de raios X monocromáticos. Para garantir a uniformidade no suporte e a representatividade da amostra, uma série de réplicas de quantidades específicas de amostras, na forma de um pó fino, foi adicionada em solução orgânica viscosa diluída contendo uma concentração conhecida de um elemento na qualidade de padrão interno. Uma alíquota da solução viscosa contendo ambos o particulado de amostra em suspensão e o padrão interno foi depositada no centro do refletor de quartzo e seca, obtendo-se uma camada fina de particulado. Primeiramente, o instrumental TXRF foi previamente avaliado quanto a operação, resposta espectral e recuperação de concentrações de metais de transição de uma amostra de teste fornecido pelo fabricante. A reprodutibilidade das medidas de concentração elementar foi testada com uma combinação da série de réplicas experimentais (cinco) e analíticas (três) para cada tipo de matriz de amostras ambientais, chamadas de Materiais de Referência Certificados ou MRC. Foram testados seis tipos de MCRs: sedimento de rio, folhas de tomate, arroz, músculo de peixe, osso e fígado bovino. Foram processados estatisticamente a série de dados de concentrações elementares de cada MCR, obtendo-se o valor médio e incerteza da concentração de cada analito de referência o qual foi comparado ao reportado nos laudos técnicos dos MCR. Considerando o caráter multielementar da técnica TXRF, verificou-se uma boa recuperação, em torno de 100%, da maioria das concentrações referenciadas e certificadas dos analitos nos seis MCRs, dentro da margem de variabilidade dos resultados encontrados pela técnica TXRF e reportados pelos laudos. Verificou-se também que o limite de detecção depende da densidade da matriz do material sob estudo. Contudo, os elementos de transição foram os que apresentaram os menores valores de limites de detecção. Tendo a boa recuperação das concentrações de analitos maioritários no material de referência sedimento Buffalo River, foi aplicada a mesma metodologia para análise de material de sedimento do córrego Bezerra-Cascavel que foi coletado em três locais ao longo dele e por um período de três anos. Uma série de elementos químicos foram identificados através de suas linhas espectrais K e L, e quantificados seguindo o método do padrão interno. O conjunto de dados de concentração foi processado estatisticamente do ponto de vista da normalidade dos dados e feita uma análise de componentes principais, revelando uma sistemática presença de altas concentrações de metais pesados, tais como chumbo e cromo, comparativamente maiores daqueles preconizados pela atual legislação ambiental (CONAMA 420/2009) quanto aos limites máximos permissíveis.Submitted by Marilene Donadel (marilene.donadel@unioeste.br) on 2018-04-25T00:28:56Z No. of bitstreams: 1 Joelmir_Santos_2016.pdf: 3759768 bytes, checksum: 953ccb765b5bea358bd87b6b493ab5cb (MD5)Made available in DSpace on 2018-04-25T00:28:56Z (GMT). No. of bitstreams: 1 Joelmir_Santos_2016.pdf: 3759768 bytes, checksum: 953ccb765b5bea358bd87b6b493ab5cb (MD5) Previous issue date: 2016-02-29Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfpor-2624803687637593200500Universidade Estadual do Oeste do ParanáToledoPrograma de Pós-Graduação em Engenharia QuímicaUNIOESTEBrasilCentro de Engenharias e Ciências ExatasConcentração de metais em partículasElementos maioritários, intermediários e traçoAnálise estatística de dadosTécnica FRXValidação estatística.Data statistical analysisDeveloped and validated XRF methodologyMetal concentration analysis in particulatemain and trace elements;ENGENHARIAS::ENGENHARIA QUIMICAAvaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientaisEvaluation and technical application of the methodology of the total reflection X-ray fluorescence spectrometry (TXRF) in multi-element characterization of particulate solids from environmental samplesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis1582274381427649589600600600600-7734402124082146922-18486402610968708782075167498588264571info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações do UNIOESTEinstname:Universidade Estadual do Oeste do Paraná (UNIOESTE)instacron:UNIOESTEORIGINALJoelmir_Santos_2016.pdfJoelmir_Santos_2016.pdfapplication/pdf3759768http://tede.unioeste.br:8080/tede/bitstream/tede/3571/2/Joelmir_Santos_2016.pdf953ccb765b5bea358bd87b6b493ab5cbMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://tede.unioeste.br:8080/tede/bitstream/tede/3571/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/35712018-04-24 21:28:56.39oai:tede.unioeste.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede.unioeste.br/PUBhttp://tede.unioeste.br/oai/requestbiblioteca.repositorio@unioeste.bropendoar:2018-04-25T00:28:56Biblioteca Digital de Teses e Dissertações do UNIOESTE - Universidade Estadual do Oeste do Paraná (UNIOESTE)false
dc.title.por.fl_str_mv Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
dc.title.alternative.eng.fl_str_mv Evaluation and technical application of the methodology of the total reflection X-ray fluorescence spectrometry (TXRF) in multi-element characterization of particulate solids from environmental samples
title Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
spellingShingle Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
Santos, Joelmir dos
Concentração de metais em partículas
Elementos maioritários, intermediários e traço
Análise estatística de dados
Técnica FRX
Validação estatística.
Data statistical analysis
Developed and validated XRF methodology
Metal concentration analysis in particulate
main and trace elements;
ENGENHARIAS::ENGENHARIA QUIMICA
title_short Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
title_full Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
title_fullStr Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
title_full_unstemmed Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
title_sort Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais
author Santos, Joelmir dos
author_facet Santos, Joelmir dos
author_role author
dc.contributor.advisor1.fl_str_mv Espinoza Quiñones, Fernando Rodolfo
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/7943425772967712
dc.contributor.advisor-co1.fl_str_mv Módenes, Aparecido Nivaldo
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/7294940837327863
dc.contributor.referee1.fl_str_mv Espinoza Quiñones, Fernando Rodolfo
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/7943425772967712
dc.contributor.referee2.fl_str_mv Dragunski, Douglas Cardoso
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/0612112281360342
dc.contributor.referee3.fl_str_mv Frigori, Rafael Bertolini
dc.contributor.referee3Lattes.fl_str_mv http://lattes.cnpq.br/5836878566801544
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/5955061598962138
dc.contributor.author.fl_str_mv Santos, Joelmir dos
contributor_str_mv Espinoza Quiñones, Fernando Rodolfo
Módenes, Aparecido Nivaldo
Espinoza Quiñones, Fernando Rodolfo
Dragunski, Douglas Cardoso
Frigori, Rafael Bertolini
dc.subject.por.fl_str_mv Concentração de metais em partículas
Elementos maioritários, intermediários e traço
Análise estatística de dados
Técnica FRX
Validação estatística.
Data statistical analysis
Developed and validated XRF methodology
topic Concentração de metais em partículas
Elementos maioritários, intermediários e traço
Análise estatística de dados
Técnica FRX
Validação estatística.
Data statistical analysis
Developed and validated XRF methodology
Metal concentration analysis in particulate
main and trace elements;
ENGENHARIAS::ENGENHARIA QUIMICA
dc.subject.eng.fl_str_mv Metal concentration analysis in particulate
main and trace elements;
dc.subject.cnpq.fl_str_mv ENGENHARIAS::ENGENHARIA QUIMICA
description This study aimed the evaluation and application of methodology for multielement analyses by total reflection X-ray fluorescence spectrometry (TXRF) in order to provide analyte concentration measurements with accuracy and precision. Using the energy and intensity of the spectral lines of characteristic X-ray, a series of chemicals were identified and quantified, respectively, with a concentration below part per million to a few parts per billion, especially for transition metals. To ensure statistical reliability and reproducibility, a methodology based on the deposition of fine particles, less than 50 m, representative sample and uniformly spread on a quartz flat reflector, which was extremely clean and positioned at the angular condition of maximum reflectivity of monochromatic X-rays was applied. To ensure uniformity on the support surface and the sample representativeness, a number of replicas of specific quantities of samples, in the form of a fine powder was added in a diluted viscous organic solution containing a well-known concentration of an element choosing as internal standard. An aliquot of the viscous solution containing both the suspended particulate sample and an internal standard was deposited at the center of the quartz reflector and dried, yielding a very thin layer of particulates. First, the instrumental TXRF was previously evaluated for its operation, spectral response and recovery of transition metal concentrations in a test sample supplied by the manufacturer. The reproducibility of the elemental concentration measurements was tested with a combination of the number of experimental replicates (five) and analytical (three) for each type of environmental matrix samples, namely certified reference materials or CRMs. Six types of CRMs were tested: river sediment, tomato leaves, rice, fish muscle, bone and bovine liver. The data were statistically processed data, resulting in a series of average and uncertainty values of the analyte concentrations was compared to certified reference values, reported in the technical reports of CRM. Regarding the multielement character of the TXRF technique, there was a good recovery, about 100%, for most of the certified concentrations of the referenced analytes in the six CRMs within the margin of variability of results found by both the TXRF technique and reports. It was also found that the detection limit depends on the density matrix of the material under study. However, the transition elements were those with the lowest values of detection limits. Having a good recovery of majority analyte concentrations in Buffalo River sediment reference material, the same methodology was applied to sediment material analysis of Bezerra stream that was collected in three locations and for a period of three years. A number of chemicals has been identified through their spectral lines K and L and quantified following the internal standard method. The set of concentration data was statistically processed from the point of view of the normality of the data and an analysis of principal components, revealing a systematic presence of high concentrations of heavy metals such as lead and chromium, comparatively higher those recommended by current environmental legislation (CONAMA 420/2009) as the maximum permissible limits.
publishDate 2016
dc.date.issued.fl_str_mv 2016-02-29
dc.date.accessioned.fl_str_mv 2018-04-25T00:28:56Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SANTOS, Joelmir dos. Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais. 2016. 138 f. Dissertação (Mestrado em Engenharia Química) - Universidade Estadual do Oeste do Paraná, Toledo, 2016.
dc.identifier.uri.fl_str_mv http://tede.unioeste.br/handle/tede/3571
identifier_str_mv SANTOS, Joelmir dos. Avaliação e aplicação de metodologia da técnica espectrométrica de fluorescência de raios X por reflexão total (TXRF) na caracterização multielementar em particulados sólidos de amostras ambientais. 2016. 138 f. Dissertação (Mestrado em Engenharia Química) - Universidade Estadual do Oeste do Paraná, Toledo, 2016.
url http://tede.unioeste.br/handle/tede/3571
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv 1582274381427649589
dc.relation.confidence.fl_str_mv 600
600
600
600
dc.relation.department.fl_str_mv -7734402124082146922
dc.relation.cnpq.fl_str_mv -1848640261096870878
dc.relation.sponsorship.fl_str_mv 2075167498588264571
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual do Oeste do Paraná
Toledo
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Química
dc.publisher.initials.fl_str_mv UNIOESTE
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Centro de Engenharias e Ciências Exatas
publisher.none.fl_str_mv Universidade Estadual do Oeste do Paraná
Toledo
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações do UNIOESTE
instname:Universidade Estadual do Oeste do Paraná (UNIOESTE)
instacron:UNIOESTE
instname_str Universidade Estadual do Oeste do Paraná (UNIOESTE)
instacron_str UNIOESTE
institution UNIOESTE
reponame_str Biblioteca Digital de Teses e Dissertações do UNIOESTE
collection Biblioteca Digital de Teses e Dissertações do UNIOESTE
bitstream.url.fl_str_mv http://tede.unioeste.br:8080/tede/bitstream/tede/3571/2/Joelmir_Santos_2016.pdf
http://tede.unioeste.br:8080/tede/bitstream/tede/3571/1/license.txt
bitstream.checksum.fl_str_mv 953ccb765b5bea358bd87b6b493ab5cb
bd3efa91386c1718a7f26a329fdcb468
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações do UNIOESTE - Universidade Estadual do Oeste do Paraná (UNIOESTE)
repository.mail.fl_str_mv biblioteca.repositorio@unioeste.br
_version_ 1801124548587814912