Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis

Detalhes bibliográficos
Autor(a) principal: Ribeiro, Cyntia Ferreira
Data de Publicação: 2006
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UNITAU
Texto Completo: http://repositorio.unitau.br/jspui/handle/20.500.11874/3325
Resumo: Orientação: Prof. Dr. Sigmar de Mello Rode
id UNITAU_224a61469132bfbd4801ea2fb7a746ac
oai_identifier_str oai:repositorio.unitau.br:20.500.11874/3325
network_acronym_str UNITAU
network_name_str Repositório Institucional da UNITAU
repository_id_str
spelling Ribeiro, Cyntia FerreiraAlves, Ana Paula RosifiniNeves, Ana Christina Claro, 1957-Universidade de Taubaté. Programa de Pós-graduação em OdontologiaRode, Sigmar de Mello2023-03-17T18:36:20Z2023-03-17T18:36:20Z2006http://repositorio.unitau.br/jspui/handle/20.500.11874/3325Orientação: Prof. Dr. Sigmar de Mello RodeDissertação (mestrado) - Universidade de Taubaté, Programa de Pós-graduação em Odontologia, Taubaté, 2006.Resumo: A higienização das próteses parciais removíveis é fundamental para a durabilidade do tratamento reabilitador e prevenção de patologias dos tecidos bucais, o que inclui cuidados caseiros. Com os avanços nos procedimentos para fundição do titânio e por suas características como excelente resistência à corrosão, biocompatibilidade e alta resistência mecânica, o seu uso é defendido na confecção de armações metálicas para prótese parcial removível. O objetivo desta pesquisa experimental foi verificar in vitro a ocorrência de alterações na superfície do titânio comercialmente puro fundido utilizado na confecção de armações metálicas destas próteses, após imersão em soluções de hipoclorito de sódio 2% e em soluções obtidas de tabletes efervescentes com oxigênio ativo e perborato de sódio (Corega® Tabs). Dezenove corpos-de-prova de titânio comercialmente puro fundidos com 11mm X 6mm foram separados em três grupos com seis amostras cada, os quais ficaram em recipiente plástico com cloreto de sódio 0,9% dentro de um aquário com temperatura de 37°C. Um corpo-de-prova foi mantido em meio seco, o qual serviu de padrão para análise da superfície dos demais. Todos os dias, os 18 corpos-de-prova foram retirados e imersos em meio com soluções higienizadoras de prótese por cinco minutos. O grupo I (n=6) em meio com solução de Corega® Tabs, grupo II (n=6) em hipoclorito de sódio a 2% e o grupo III (n=6), que serviu de controle, em água destilada. Após este período, todos os corpos-de-prova foram lavados com água destilada por dez segundos e colocados em seus recipientes. Após trinta dias, obedecendo todos os processos acima citados, as superfícies foram limpas e secas para realização da análise de suas superfícies no microscópio de luz, no microscópio eletrônico de varredura e no rugosímetro. A análise no microscópio eletrônico de varredura mostrou alterações superficiais nos corpos-de-prova que foram imersos no Corega® Tabs e no hipoclorito de sódio a 2%, o que não foi observado no grupo III. Na microscopia de luz polarizada observou-se corrosão por pite na superfície das amostras higienizadas com solução de Corega® Tabs. O programa SPSS foi utilizado para calcular a diferença nas medidas da leitura da rugosidade superficial e a análise estatística com os testes t-Student; teste F (ANOVA); e teste F de Levene, não mostrou diferença estatisticamente significante, ao nível de 5%, entre os grupos que foram higienizados e o corpo-de-prova padrão, nem entre os diferentes grupos que foram submetidos aos higienizadores. Com base nestes dados, não se recomenda que os higienizadores Corega® Tabs e hipoclorito de sódio a 2% sejam utilizados em próteses com componentes fundidos em titânio comercialmente puro, pois causam alterações superficiais, embora não causem mudanças na rugosidade superficial.Abstract: The cleansing of the removable partial denture is fundamental for the durability of the rehabilitator treatment and prevention of oral tissues pathologies, what includes household care. With the progresses in the casting of the titanium and their characteristics as excellent resistance to corrosion, biocompatibility, high mechanical resistance, its use is defended in the construction of metallic frameworks for removable partial dentures. The aim of this experimental research was to verify the occurrence of alterations in the surface of the commercially pure casting titanium used in the construction of metallic frameworks of these prostheses, after immersion in solutions of sodium hypochlorite 2% and in obtained solutions of effervescent tablets with active oxygen and of sodium percolate (Corega ® Tabs). Nineteen specimens of commercially pure titanium they were casting with 11mm X 6mm and separate in three groups with six specimens each, which were inside in plastic taps with sodium chloride at 0,9% of an aquarium with temperature of 37°C. A specimen was maintained in dry medium, which served as pattern for analysis of the surface of the others. Everyday, the 18 specimens were solitary and immersed in medium with solutions dentures cleansers for five minutes. The group I (n=6) in a medium with solution of Corega ® Tabs, group II (n=6) in sodium hypochlorite at 2% and the group III (n=6), that it served as control, in distilled water. After this period, all of the specimens were washed with distilled water for ten seconds and put in their containers. After thirty days following all the procedures above, the surfaces went clean and droughts to perform the analysis of their surfaces in the light microscope, in the Scanning Electron Microscope and in the rugosimeter. The analysis in the scanning electron microscope showed superficial alterations in the specimens that were immersed in Corega ® Tabs and in the hypochlorite of sodium at 2%, what was not observed in the group III. In the light microscope showed corrosion pit in the surface of the specimes of the group I. The software SPSS was used to calculate the difference in the measures of the reading of the superficial roughness and the statistical analysis with the tests t-Student; test F (ANOVA); and test F of Levene, didn't show statistically significant differences, at the level of 5%, among the groups that were cleansing and pattern specimen, nor enter the different groups that were submitted to the cleansers. According to this data, it is not recommended that the cleansers like Corega® Tabs and hypochlorite of sodium at 2% to be used in prostheses with casting commercially pure titanium components, because they cause surface alterations, although they don't cause changes in roughness surface.Made available in DSpace on 2023-03-17T18:36:20Z (GMT). No. of bitstreams: 1 Cyntia Ferreira Ribeiro.pdf: 2068984 bytes, checksum: 4365d87c5a89e80401a95cb7ad4e4844 (MD5) Previous issue date: 20061 recurso online (66 f.) : il. : digital, arquivo PDF.application/pdfRequisitos do sistema: Software para leitura de arquivo em PDF.Prótese parcial removívelHigienizadores de próteseHigienizadores de dentaduraEfeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UNITAUinstname:Universidade de Taubaté (UNITAU)instacron:UNITAUORIGINALCyntia Ferreira Ribeiro.pdfapplication/pdf2068984http://repositorio.unitau.br:8080/jspui/bitstream/20.500.11874/3325/1/Cyntia%20Ferreira%20Ribeiro.pdf4365d87c5a89e80401a95cb7ad4e4844MD5120.500.11874/33252023-03-17 15:36:20.3oai:repositorio.unitau.br:20.500.11874/3325Repositório InstitucionalPUBhttp://repositorio.unitau.br/oai/requestopendoar:2023-03-17T18:36:20Repositório Institucional da UNITAU - Universidade de Taubaté (UNITAU)false
dc.title.pt_BR.fl_str_mv Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
title Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
spellingShingle Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
Ribeiro, Cyntia Ferreira
Prótese parcial removível
Higienizadores de prótese
Higienizadores de dentadura
title_short Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
title_full Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
title_fullStr Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
title_full_unstemmed Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
title_sort Efeito de soluções limpadoras em superfície de titânio utilizado em armações metálicas de próteses parciais removíveis
author Ribeiro, Cyntia Ferreira
author_facet Ribeiro, Cyntia Ferreira
author_role author
dc.contributor.other.pt_BR.fl_str_mv Alves, Ana Paula Rosifini
Neves, Ana Christina Claro, 1957-
Universidade de Taubaté. Programa de Pós-graduação em Odontologia
dc.contributor.author.fl_str_mv Ribeiro, Cyntia Ferreira
dc.contributor.advisor1.fl_str_mv Rode, Sigmar de Mello
contributor_str_mv Rode, Sigmar de Mello
dc.subject.por.fl_str_mv Prótese parcial removível
Higienizadores de prótese
Higienizadores de dentadura
topic Prótese parcial removível
Higienizadores de prótese
Higienizadores de dentadura
description Orientação: Prof. Dr. Sigmar de Mello Rode
publishDate 2006
dc.date.issued.fl_str_mv 2006
dc.date.accessioned.fl_str_mv 2023-03-17T18:36:20Z
dc.date.available.fl_str_mv 2023-03-17T18:36:20Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.unitau.br/jspui/handle/20.500.11874/3325
url http://repositorio.unitau.br/jspui/handle/20.500.11874/3325
dc.language.iso.fl_str_mv por
language por
dc.relation.requires.pt_BR.fl_str_mv Requisitos do sistema: Software para leitura de arquivo em PDF.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1 recurso online (66 f.) : il. : digital, arquivo PDF.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNITAU
instname:Universidade de Taubaté (UNITAU)
instacron:UNITAU
instname_str Universidade de Taubaté (UNITAU)
instacron_str UNITAU
institution UNITAU
reponame_str Repositório Institucional da UNITAU
collection Repositório Institucional da UNITAU
bitstream.url.fl_str_mv http://repositorio.unitau.br:8080/jspui/bitstream/20.500.11874/3325/1/Cyntia%20Ferreira%20Ribeiro.pdf
bitstream.checksum.fl_str_mv 4365d87c5a89e80401a95cb7ad4e4844
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UNITAU - Universidade de Taubaté (UNITAU)
repository.mail.fl_str_mv
_version_ 1813263160276156416