Aspectos ultrassonográficos da glândula tireoide hígida em equinos

Detalhes bibliográficos
Autor(a) principal: Viana, Gustavo Fernandes [UNESP]
Data de Publicação: 2015
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/131894
Resumo: The application of ultrasonography can provide valuable data for efficient clinical and surgical intervention in cases of thyroid disorders. However, there are few studies related to the use of the USG as an evaluation method of the thyroid gland (TG) in horses. The objective was to establish analysis parameters of healthy TG in adult horses by B and Doppler mode ultrasonography. Eleven horses (twenty-two thyroid lobes) were selected through negative for thyroid disorders on clinical examination, laboratory (free thyroxine by equilibrium dialysis), USG and cytology. It was determined the means and standard deviations of dimensions of the thyroid lobes (TLs), and peak systolic velocity, resistive and pulsatility index their respective cranial thyroid arteries (ACTs). The contours, echotexture, echogenicity and parenchymal color flow pattern (PCFP) thyroid were also evaluated. There were no significant differences between values obtained for the left and right TLs. The same happened to left and right ACTs. The USG proved an efficient diagnostic methodology for defining the TG reference values in adult horses. Although the left and right TLs may present distinct general format in the same animal, other parameters as the dimensions, contours, parenchymal and vascular characteristics were similar. From these criteria, if one of the lobes is affected by thyroid disorders, the contralateral lobe could form the basis for evaluation of another lobe changed. In addition, the study unilateral ACT spectral Doppler parameters may be used to evaluate diffuse thyroid disorder
id UNSP_009f0fbbc32f3e94dac429836e6da215
oai_identifier_str oai:repositorio.unesp.br:11449/131894
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Aspectos ultrassonográficos da glândula tireoide hígida em equinosUltrasonographic features of the healthy throid gland in horsesUltrassonografia veterináriaCavalo - DoençasTireoide - DoençasVeterinary ultrasonographyThe application of ultrasonography can provide valuable data for efficient clinical and surgical intervention in cases of thyroid disorders. However, there are few studies related to the use of the USG as an evaluation method of the thyroid gland (TG) in horses. The objective was to establish analysis parameters of healthy TG in adult horses by B and Doppler mode ultrasonography. Eleven horses (twenty-two thyroid lobes) were selected through negative for thyroid disorders on clinical examination, laboratory (free thyroxine by equilibrium dialysis), USG and cytology. It was determined the means and standard deviations of dimensions of the thyroid lobes (TLs), and peak systolic velocity, resistive and pulsatility index their respective cranial thyroid arteries (ACTs). The contours, echotexture, echogenicity and parenchymal color flow pattern (PCFP) thyroid were also evaluated. There were no significant differences between values obtained for the left and right TLs. The same happened to left and right ACTs. The USG proved an efficient diagnostic methodology for defining the TG reference values in adult horses. Although the left and right TLs may present distinct general format in the same animal, other parameters as the dimensions, contours, parenchymal and vascular characteristics were similar. From these criteria, if one of the lobes is affected by thyroid disorders, the contralateral lobe could form the basis for evaluation of another lobe changed. In addition, the study unilateral ACT spectral Doppler parameters may be used to evaluate diffuse thyroid disorderA aplicação da ultrassonografia (USG) pode fornecer dados valiosos para eficiente intervenção clínica e cirúrgica em casos de alterações tireoidianas. Entretanto, existem poucos estudos relacionados ao emprego da USG como método de avaliação da glândula tireoide (GT) em cavalos. Portanto, foi objetivo estabelecer parâmetros de análise da GT hígida em equinos adultos através do exame ultrassonográfico em modo B e Doppler. Onze equinos (vinte e dois lobos tireoidianos) foram selecionados através de resultados negativos para tireopatias no exame clínico, laboratorial (tiroxina livre por diálise de equilíbrio), ultrassonográfico e citológico. Foram determinadas as médias e os desvios padrão das dimensões dos lobos tireoidianos (LTs), e a velocidade do pico sistólico, índice de resistividade e pulsatilidade de suas respectivas artérias tireoideas craniais (ATCs). Os contornos, ecotextura, ecogenicidade e padrão do fluxo em cores do parênquima (PFCP) tireoidiano foram também avaliados. Não houve diferenças significativas entre as médias dos valores obtidos para os LTs esquerdo e direito. O mesmo ocorreu para ATC esquerda e direita. A USG se mostrou uma eficiente metodologia diagnóstica para definir os valores de referência da GT em equinos adultos. Apesar dos LTs esquerdo e direito poderem apresentar formato geral distinto num mesmo animal, outros parâmetros como as dimensões, contornos, características do parênquima e vascularização se mostraram semelhantes. A partir desses critérios, se um dos lobos for acometido por tireopatia, o lobo contra-lateral poderá servir de base para avaliação do outro alterado. Além disso, os parâmetros do Doppler espectral unilateral da ATC poderá ser utilizado para avaliar doenças tireoidianas difusasConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Universidade Estadual Paulista (Unesp)Machado, Vânia Maria de Vasconcelos [UNESP]Hataka, Alessandre [UNESP]Universidade Estadual Paulista (Unesp)Viana, Gustavo Fernandes [UNESP]2015-12-10T14:22:26Z2015-12-10T14:22:26Z2015-06-22info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis57 f.application/pdfVIANA, Gustavo Fernandes. Aspectos ultrassonográficos da glândula tireoide hígida em equinos. 2015. 57 f. Dissertação (mestrado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Medicina Veterinária e Zootecnia, 2015.http://hdl.handle.net/11449/131894000852786000852786.pdf33004064086P1Alephreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporinfo:eu-repo/semantics/openAccess2024-09-09T17:21:40Zoai:repositorio.unesp.br:11449/131894Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-09T17:21:40Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Aspectos ultrassonográficos da glândula tireoide hígida em equinos
Ultrasonographic features of the healthy throid gland in horses
title Aspectos ultrassonográficos da glândula tireoide hígida em equinos
spellingShingle Aspectos ultrassonográficos da glândula tireoide hígida em equinos
Viana, Gustavo Fernandes [UNESP]
Ultrassonografia veterinária
Cavalo - Doenças
Tireoide - Doenças
Veterinary ultrasonography
title_short Aspectos ultrassonográficos da glândula tireoide hígida em equinos
title_full Aspectos ultrassonográficos da glândula tireoide hígida em equinos
title_fullStr Aspectos ultrassonográficos da glândula tireoide hígida em equinos
title_full_unstemmed Aspectos ultrassonográficos da glândula tireoide hígida em equinos
title_sort Aspectos ultrassonográficos da glândula tireoide hígida em equinos
author Viana, Gustavo Fernandes [UNESP]
author_facet Viana, Gustavo Fernandes [UNESP]
author_role author
dc.contributor.none.fl_str_mv Machado, Vânia Maria de Vasconcelos [UNESP]
Hataka, Alessandre [UNESP]
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Viana, Gustavo Fernandes [UNESP]
dc.subject.por.fl_str_mv Ultrassonografia veterinária
Cavalo - Doenças
Tireoide - Doenças
Veterinary ultrasonography
topic Ultrassonografia veterinária
Cavalo - Doenças
Tireoide - Doenças
Veterinary ultrasonography
description The application of ultrasonography can provide valuable data for efficient clinical and surgical intervention in cases of thyroid disorders. However, there are few studies related to the use of the USG as an evaluation method of the thyroid gland (TG) in horses. The objective was to establish analysis parameters of healthy TG in adult horses by B and Doppler mode ultrasonography. Eleven horses (twenty-two thyroid lobes) were selected through negative for thyroid disorders on clinical examination, laboratory (free thyroxine by equilibrium dialysis), USG and cytology. It was determined the means and standard deviations of dimensions of the thyroid lobes (TLs), and peak systolic velocity, resistive and pulsatility index their respective cranial thyroid arteries (ACTs). The contours, echotexture, echogenicity and parenchymal color flow pattern (PCFP) thyroid were also evaluated. There were no significant differences between values obtained for the left and right TLs. The same happened to left and right ACTs. The USG proved an efficient diagnostic methodology for defining the TG reference values in adult horses. Although the left and right TLs may present distinct general format in the same animal, other parameters as the dimensions, contours, parenchymal and vascular characteristics were similar. From these criteria, if one of the lobes is affected by thyroid disorders, the contralateral lobe could form the basis for evaluation of another lobe changed. In addition, the study unilateral ACT spectral Doppler parameters may be used to evaluate diffuse thyroid disorder
publishDate 2015
dc.date.none.fl_str_mv 2015-12-10T14:22:26Z
2015-12-10T14:22:26Z
2015-06-22
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv VIANA, Gustavo Fernandes. Aspectos ultrassonográficos da glândula tireoide hígida em equinos. 2015. 57 f. Dissertação (mestrado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Medicina Veterinária e Zootecnia, 2015.
http://hdl.handle.net/11449/131894
000852786
000852786.pdf
33004064086P1
identifier_str_mv VIANA, Gustavo Fernandes. Aspectos ultrassonográficos da glândula tireoide hígida em equinos. 2015. 57 f. Dissertação (mestrado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Medicina Veterinária e Zootecnia, 2015.
000852786
000852786.pdf
33004064086P1
url http://hdl.handle.net/11449/131894
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 57 f.
application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual Paulista (Unesp)
publisher.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.source.none.fl_str_mv Aleph
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1810021323479449600