Thermodynamic response of an ultrasonic densitometer
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/68684 |
Resumo: | An ultrasonic densitometer is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 to 40°C temperature range. Results are compared to tabulated values in the case of distilled water, showing accuracy of 0.07% for the propagation velocity. Density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% under thermal gradient conditions. |
id |
UNSP_07ad930c0d1fd01eab44963af0f4e593 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/68684 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Thermodynamic response of an ultrasonic densitometerDensity valueDistilled waterPropagation velocitiesTemperature rangeDensitometersMeteorological instrumentsDensity of liquidsAn ultrasonic densitometer is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 to 40°C temperature range. Results are compared to tabulated values in the case of distilled water, showing accuracy of 0.07% for the propagation velocity. Density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% under thermal gradient conditions.Dep. Electrical Engineering Universidade Estadual Paulista - Unesp, Avenida Brasil, 56, CEP 15385-000, Ilha Solteira, SPDep. Mechatronics and Mechanical Systems Engineering Escola Politécnica da USP, Av. Prof. Mello Moraes, 2231, CEP 05508-900, São Paulo, SPDep. Electrical Engineering Universidade Estadual Paulista - Unesp, Avenida Brasil, 56, CEP 15385-000, Ilha Solteira, SPUniversidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Higuti, R. T. [UNESP]Galindo, B. S. [UNESP]Kitano, C. [UNESP]Buiochi, F.Adamowski, J. C.2014-05-27T11:21:46Z2014-05-27T11:21:46Z2005-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject4137-4144International Congress on Noise Control Engineering 2005, INTERNOISE 2005, v. 5, p. 4137-4144.http://hdl.handle.net/11449/686842-s2.0-84873818773640533951088320328834403518951670000-0003-4201-56170000-0001-6320-755XScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Congress on Noise Control Engineering 2005, INTERNOISE 2005info:eu-repo/semantics/openAccess2022-01-11T17:18:07Zoai:repositorio.unesp.br:11449/68684Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-01-11T17:18:07Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Thermodynamic response of an ultrasonic densitometer |
title |
Thermodynamic response of an ultrasonic densitometer |
spellingShingle |
Thermodynamic response of an ultrasonic densitometer Higuti, R. T. [UNESP] Density value Distilled water Propagation velocities Temperature range Densitometers Meteorological instruments Density of liquids |
title_short |
Thermodynamic response of an ultrasonic densitometer |
title_full |
Thermodynamic response of an ultrasonic densitometer |
title_fullStr |
Thermodynamic response of an ultrasonic densitometer |
title_full_unstemmed |
Thermodynamic response of an ultrasonic densitometer |
title_sort |
Thermodynamic response of an ultrasonic densitometer |
author |
Higuti, R. T. [UNESP] |
author_facet |
Higuti, R. T. [UNESP] Galindo, B. S. [UNESP] Kitano, C. [UNESP] Buiochi, F. Adamowski, J. C. |
author_role |
author |
author2 |
Galindo, B. S. [UNESP] Kitano, C. [UNESP] Buiochi, F. Adamowski, J. C. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Higuti, R. T. [UNESP] Galindo, B. S. [UNESP] Kitano, C. [UNESP] Buiochi, F. Adamowski, J. C. |
dc.subject.por.fl_str_mv |
Density value Distilled water Propagation velocities Temperature range Densitometers Meteorological instruments Density of liquids |
topic |
Density value Distilled water Propagation velocities Temperature range Densitometers Meteorological instruments Density of liquids |
description |
An ultrasonic densitometer is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 to 40°C temperature range. Results are compared to tabulated values in the case of distilled water, showing accuracy of 0.07% for the propagation velocity. Density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% under thermal gradient conditions. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-12-01 2014-05-27T11:21:46Z 2014-05-27T11:21:46Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
International Congress on Noise Control Engineering 2005, INTERNOISE 2005, v. 5, p. 4137-4144. http://hdl.handle.net/11449/68684 2-s2.0-84873818773 6405339510883203 2883440351895167 0000-0003-4201-5617 0000-0001-6320-755X |
identifier_str_mv |
International Congress on Noise Control Engineering 2005, INTERNOISE 2005, v. 5, p. 4137-4144. 2-s2.0-84873818773 6405339510883203 2883440351895167 0000-0003-4201-5617 0000-0001-6320-755X |
url |
http://hdl.handle.net/11449/68684 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
International Congress on Noise Control Engineering 2005, INTERNOISE 2005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
4137-4144 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1803650121460613120 |