DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/197459 |
Resumo: | This work presents the most relevant aspects of the SnO2 based varistors technology and a comparative study of its non linear behavior in relation to ZnO (modified Matsuoka system) varistors. Electrical performance at low and high impulse currents is presented. The SnO2 system had shown beUer performance in important parameters when compared to SnO2 system such as higher non linear coefficients in the entire range of measured currents and much higher electrical breakdown field. It was also evaluated the degradation both technologies of varistors subjected to lightning current pulses (8/20 mu s) resulting a more severe degradation in the ZnO varistors. The improved behavior of the SnO2 system forms the basis to a forthcoming design of surge arresters and surge protective devices based on such technology. |
id |
UNSP_09f5b9a4154ed2357d383e19a21cee4c |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/197459 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORSvaristorsprotectiontechnologyZnOSnO2energydegradationsurge arrestersThis work presents the most relevant aspects of the SnO2 based varistors technology and a comparative study of its non linear behavior in relation to ZnO (modified Matsuoka system) varistors. Electrical performance at low and high impulse currents is presented. The SnO2 system had shown beUer performance in important parameters when compared to SnO2 system such as higher non linear coefficients in the entire range of measured currents and much higher electrical breakdown field. It was also evaluated the degradation both technologies of varistors subjected to lightning current pulses (8/20 mu s) resulting a more severe degradation in the ZnO varistors. The improved behavior of the SnO2 system forms the basis to a forthcoming design of surge arresters and surge protective devices based on such technology.Univ Sao Paulo, Sao Paulo, BrazilSao Paulo State Univ Unesp, Sao Paulo, BrazilSao Paulo State Univ Unesp, Sao Paulo, BrazilIeeeUniversidade de São Paulo (USP)Universidade Estadual Paulista (Unesp)Bassi, W.Ramirez, M. A. [UNESP]Bueno, P. R. [UNESP]Longo, E. [UNESP]Varela, J. A. [UNESP]IEEE2020-12-10T22:32:15Z2020-12-10T22:32:15Z2010-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject42010 30th International Conference On Lightning Protection (iclp). New York: Ieee, 4 p., 2010.2469-8784http://hdl.handle.net/11449/197459WOS:000394698300017Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2010 30th International Conference On Lightning Protection (iclp)info:eu-repo/semantics/openAccess2021-10-23T14:48:13Zoai:repositorio.unesp.br:11449/197459Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:34:52.641481Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
title |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
spellingShingle |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS Bassi, W. varistors protection technology ZnO SnO2 energy degradation surge arresters |
title_short |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
title_full |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
title_fullStr |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
title_full_unstemmed |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
title_sort |
DEVELOPMENT OF SNO2 BASED VARISTORS - ELECTRICAL BEHAVIOR AND PULSE DEGRADATION COMPARATIVELY TO ZNO VARISTORS |
author |
Bassi, W. |
author_facet |
Bassi, W. Ramirez, M. A. [UNESP] Bueno, P. R. [UNESP] Longo, E. [UNESP] Varela, J. A. [UNESP] IEEE |
author_role |
author |
author2 |
Ramirez, M. A. [UNESP] Bueno, P. R. [UNESP] Longo, E. [UNESP] Varela, J. A. [UNESP] IEEE |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade de São Paulo (USP) Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Bassi, W. Ramirez, M. A. [UNESP] Bueno, P. R. [UNESP] Longo, E. [UNESP] Varela, J. A. [UNESP] IEEE |
dc.subject.por.fl_str_mv |
varistors protection technology ZnO SnO2 energy degradation surge arresters |
topic |
varistors protection technology ZnO SnO2 energy degradation surge arresters |
description |
This work presents the most relevant aspects of the SnO2 based varistors technology and a comparative study of its non linear behavior in relation to ZnO (modified Matsuoka system) varistors. Electrical performance at low and high impulse currents is presented. The SnO2 system had shown beUer performance in important parameters when compared to SnO2 system such as higher non linear coefficients in the entire range of measured currents and much higher electrical breakdown field. It was also evaluated the degradation both technologies of varistors subjected to lightning current pulses (8/20 mu s) resulting a more severe degradation in the ZnO varistors. The improved behavior of the SnO2 system forms the basis to a forthcoming design of surge arresters and surge protective devices based on such technology. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-01-01 2020-12-10T22:32:15Z 2020-12-10T22:32:15Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
2010 30th International Conference On Lightning Protection (iclp). New York: Ieee, 4 p., 2010. 2469-8784 http://hdl.handle.net/11449/197459 WOS:000394698300017 |
identifier_str_mv |
2010 30th International Conference On Lightning Protection (iclp). New York: Ieee, 4 p., 2010. 2469-8784 WOS:000394698300017 |
url |
http://hdl.handle.net/11449/197459 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2010 30th International Conference On Lightning Protection (iclp) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
4 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128536222892032 |