An experimental and numerical investigation of absorber positioning in a natural convection solar drying system
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1016/j.solener.2022.08.012 http://hdl.handle.net/11449/242168 |
Resumo: | The known advantages of drying food are long term preservation, weight reduction and, consequently, minimizing the transportation and storage costs. Drying technology can also spoil the conditions for microbial growth. In this study, an indirect solar dryer with natural convection was developed, constructed and experimentally investigated for using in remote regions. It comprises three main parts: an absorber plate with 0.5 m2 surface area, a dryer chamber and an exhaust duct. The absorber plate position can be modified in this device and change the airflow conditions from over the upper face only to the upper and lower face (double passage). Tests changing this position increased the product humidity removal rate from 0.47 g/min to 0.56 g/min, the total water removal over the day from 185 g to 220 g and the average daily thermal efficiency from 8.5% to 19.8%. The equipment performance evaluation was possible due to the presence of temperature, humidity and atmospheric pressure sensors positioned at the air inlet and outlet. A turbine-type anemometer at the air outlet was used for airflow measurements. The other three temperature sensors placed on the absorber plate and a load cell located in the drying chamber are also used. The evaporation process was recorded based on load cells installed in the drying chamber. Another model was also applied to calculate the same parameter using the mass balance. A CFD model was build to compare with the experimental results and good agreement was found. Comparison for different solar dryer setups show a better efficiency when the absorber plate is positioned in the middle of the inlet flow. |
id |
UNSP_130227220c1de7bf7ae20a9d576fc52a |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/242168 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying systemConvective solar dryerIndirect solar dryerSolar absorber panelThermal efficiencyThe known advantages of drying food are long term preservation, weight reduction and, consequently, minimizing the transportation and storage costs. Drying technology can also spoil the conditions for microbial growth. In this study, an indirect solar dryer with natural convection was developed, constructed and experimentally investigated for using in remote regions. It comprises three main parts: an absorber plate with 0.5 m2 surface area, a dryer chamber and an exhaust duct. The absorber plate position can be modified in this device and change the airflow conditions from over the upper face only to the upper and lower face (double passage). Tests changing this position increased the product humidity removal rate from 0.47 g/min to 0.56 g/min, the total water removal over the day from 185 g to 220 g and the average daily thermal efficiency from 8.5% to 19.8%. The equipment performance evaluation was possible due to the presence of temperature, humidity and atmospheric pressure sensors positioned at the air inlet and outlet. A turbine-type anemometer at the air outlet was used for airflow measurements. The other three temperature sensors placed on the absorber plate and a load cell located in the drying chamber are also used. The evaporation process was recorded based on load cells installed in the drying chamber. Another model was also applied to calculate the same parameter using the mass balance. A CFD model was build to compare with the experimental results and good agreement was found. Comparison for different solar dryer setups show a better efficiency when the absorber plate is positioned in the middle of the inlet flow.São Paulo State University (UNESP) School of EngineeringSão Paulo State University (UNESP) School of EngineeringUniversidade Estadual Paulista (UNESP)Predolin, Rodrigo Eduardo [UNESP]Ito, Mario Cesar [UNESP]Palma, Geraldo Luiz [UNESP]Scalon, Vicente Luiz [UNESP]2023-03-02T10:44:16Z2023-03-02T10:44:16Z2022-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article431-442http://dx.doi.org/10.1016/j.solener.2022.08.012Solar Energy, v. 243, p. 431-442.0038-092Xhttp://hdl.handle.net/11449/24216810.1016/j.solener.2022.08.0122-s2.0-85136240565Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengSolar Energyinfo:eu-repo/semantics/openAccess2024-06-28T13:54:58Zoai:repositorio.unesp.br:11449/242168Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:18:13.202482Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
title |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
spellingShingle |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system Predolin, Rodrigo Eduardo [UNESP] Convective solar dryer Indirect solar dryer Solar absorber panel Thermal efficiency |
title_short |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
title_full |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
title_fullStr |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
title_full_unstemmed |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
title_sort |
An experimental and numerical investigation of absorber positioning in a natural convection solar drying system |
author |
Predolin, Rodrigo Eduardo [UNESP] |
author_facet |
Predolin, Rodrigo Eduardo [UNESP] Ito, Mario Cesar [UNESP] Palma, Geraldo Luiz [UNESP] Scalon, Vicente Luiz [UNESP] |
author_role |
author |
author2 |
Ito, Mario Cesar [UNESP] Palma, Geraldo Luiz [UNESP] Scalon, Vicente Luiz [UNESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Predolin, Rodrigo Eduardo [UNESP] Ito, Mario Cesar [UNESP] Palma, Geraldo Luiz [UNESP] Scalon, Vicente Luiz [UNESP] |
dc.subject.por.fl_str_mv |
Convective solar dryer Indirect solar dryer Solar absorber panel Thermal efficiency |
topic |
Convective solar dryer Indirect solar dryer Solar absorber panel Thermal efficiency |
description |
The known advantages of drying food are long term preservation, weight reduction and, consequently, minimizing the transportation and storage costs. Drying technology can also spoil the conditions for microbial growth. In this study, an indirect solar dryer with natural convection was developed, constructed and experimentally investigated for using in remote regions. It comprises three main parts: an absorber plate with 0.5 m2 surface area, a dryer chamber and an exhaust duct. The absorber plate position can be modified in this device and change the airflow conditions from over the upper face only to the upper and lower face (double passage). Tests changing this position increased the product humidity removal rate from 0.47 g/min to 0.56 g/min, the total water removal over the day from 185 g to 220 g and the average daily thermal efficiency from 8.5% to 19.8%. The equipment performance evaluation was possible due to the presence of temperature, humidity and atmospheric pressure sensors positioned at the air inlet and outlet. A turbine-type anemometer at the air outlet was used for airflow measurements. The other three temperature sensors placed on the absorber plate and a load cell located in the drying chamber are also used. The evaporation process was recorded based on load cells installed in the drying chamber. Another model was also applied to calculate the same parameter using the mass balance. A CFD model was build to compare with the experimental results and good agreement was found. Comparison for different solar dryer setups show a better efficiency when the absorber plate is positioned in the middle of the inlet flow. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-09-01 2023-03-02T10:44:16Z 2023-03-02T10:44:16Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.solener.2022.08.012 Solar Energy, v. 243, p. 431-442. 0038-092X http://hdl.handle.net/11449/242168 10.1016/j.solener.2022.08.012 2-s2.0-85136240565 |
url |
http://dx.doi.org/10.1016/j.solener.2022.08.012 http://hdl.handle.net/11449/242168 |
identifier_str_mv |
Solar Energy, v. 243, p. 431-442. 0038-092X 10.1016/j.solener.2022.08.012 2-s2.0-85136240565 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Solar Energy |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
431-442 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129049193611264 |