Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.

Detalhes bibliográficos
Autor(a) principal: Matsubara, B. B. [UNESP]
Data de Publicação: 1993
Outros Autores: Bregagnollo, E. A. [UNESP], Tucci, P. J. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/223970
Resumo: The effect of changes in left ventricular (LV) shape and dimensions due to acute arterial hypertension induced by mechanical obstruction of the aorta for 10 min on LV mass values estimated by M-mode echocardiogram was studied in 14 anesthetized dogs. Although the systolic pressure increased from 117.5 +/- 19.9 to 175.4 +/- 22.9 mmHg altered ventricular diameter from 2.77 +/- 0.49 cm to 3.17 +/- 0.67 cm (P < 0.05) and wall thickness from 0.83 +/- 0.09 to 0.75 +/- 0.09 cm (P < 0.05), LV mass estimated before (73.5 +/- 19.1 g) and after (78.3 +/- 26.4 g) hypertension was not significantly different. We demonstrate here for the first time that changes in LV dimensions induced by acute arterial hypertension do not modify LV mass values estimated by the M-mode electrocardiogram method.
id UNSP_16bf5cf0308a5814e258c9d0910d1815
oai_identifier_str oai:repositorio.unesp.br:11449/223970
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.The effect of changes in left ventricular (LV) shape and dimensions due to acute arterial hypertension induced by mechanical obstruction of the aorta for 10 min on LV mass values estimated by M-mode echocardiogram was studied in 14 anesthetized dogs. Although the systolic pressure increased from 117.5 +/- 19.9 to 175.4 +/- 22.9 mmHg altered ventricular diameter from 2.77 +/- 0.49 cm to 3.17 +/- 0.67 cm (P < 0.05) and wall thickness from 0.83 +/- 0.09 to 0.75 +/- 0.09 cm (P < 0.05), LV mass estimated before (73.5 +/- 19.1 g) and after (78.3 +/- 26.4 g) hypertension was not significantly different. We demonstrate here for the first time that changes in LV dimensions induced by acute arterial hypertension do not modify LV mass values estimated by the M-mode electrocardiogram method.Departamento de Clínica Médica Faculdade de Medicina de Botucatu Universidade Estadual Paulista SPDepartamento de Clínica Médica Faculdade de Medicina de Botucatu Universidade Estadual Paulista SPUniversidade Estadual Paulista (UNESP)Matsubara, B. B. [UNESP]Bregagnollo, E. A. [UNESP]Tucci, P. J. [UNESP]2022-04-28T19:53:59Z2022-04-28T19:53:59Z1993-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article173-176Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.], v. 26, n. 2, p. 173-176, 1993.0100-879Xhttp://hdl.handle.net/11449/2239702-s2.0-0027539110Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.]info:eu-repo/semantics/openAccess2022-04-28T19:53:59Zoai:repositorio.unesp.br:11449/223970Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-28T19:53:59Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
title Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
spellingShingle Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
Matsubara, B. B. [UNESP]
title_short Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
title_full Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
title_fullStr Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
title_full_unstemmed Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
title_sort Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
author Matsubara, B. B. [UNESP]
author_facet Matsubara, B. B. [UNESP]
Bregagnollo, E. A. [UNESP]
Tucci, P. J. [UNESP]
author_role author
author2 Bregagnollo, E. A. [UNESP]
Tucci, P. J. [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Matsubara, B. B. [UNESP]
Bregagnollo, E. A. [UNESP]
Tucci, P. J. [UNESP]
description The effect of changes in left ventricular (LV) shape and dimensions due to acute arterial hypertension induced by mechanical obstruction of the aorta for 10 min on LV mass values estimated by M-mode echocardiogram was studied in 14 anesthetized dogs. Although the systolic pressure increased from 117.5 +/- 19.9 to 175.4 +/- 22.9 mmHg altered ventricular diameter from 2.77 +/- 0.49 cm to 3.17 +/- 0.67 cm (P < 0.05) and wall thickness from 0.83 +/- 0.09 to 0.75 +/- 0.09 cm (P < 0.05), LV mass estimated before (73.5 +/- 19.1 g) and after (78.3 +/- 26.4 g) hypertension was not significantly different. We demonstrate here for the first time that changes in LV dimensions induced by acute arterial hypertension do not modify LV mass values estimated by the M-mode electrocardiogram method.
publishDate 1993
dc.date.none.fl_str_mv 1993-01-01
2022-04-28T19:53:59Z
2022-04-28T19:53:59Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.], v. 26, n. 2, p. 173-176, 1993.
0100-879X
http://hdl.handle.net/11449/223970
2-s2.0-0027539110
identifier_str_mv Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.], v. 26, n. 2, p. 173-176, 1993.
0100-879X
2-s2.0-0027539110
url http://hdl.handle.net/11449/223970
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.]
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 173-176
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803046912097517568