Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.
Autor(a) principal: | |
---|---|
Data de Publicação: | 1993 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/223970 |
Resumo: | The effect of changes in left ventricular (LV) shape and dimensions due to acute arterial hypertension induced by mechanical obstruction of the aorta for 10 min on LV mass values estimated by M-mode echocardiogram was studied in 14 anesthetized dogs. Although the systolic pressure increased from 117.5 +/- 19.9 to 175.4 +/- 22.9 mmHg altered ventricular diameter from 2.77 +/- 0.49 cm to 3.17 +/- 0.67 cm (P < 0.05) and wall thickness from 0.83 +/- 0.09 to 0.75 +/- 0.09 cm (P < 0.05), LV mass estimated before (73.5 +/- 19.1 g) and after (78.3 +/- 26.4 g) hypertension was not significantly different. We demonstrate here for the first time that changes in LV dimensions induced by acute arterial hypertension do not modify LV mass values estimated by the M-mode electrocardiogram method. |
id |
UNSP_16bf5cf0308a5814e258c9d0910d1815 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/223970 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension.The effect of changes in left ventricular (LV) shape and dimensions due to acute arterial hypertension induced by mechanical obstruction of the aorta for 10 min on LV mass values estimated by M-mode echocardiogram was studied in 14 anesthetized dogs. Although the systolic pressure increased from 117.5 +/- 19.9 to 175.4 +/- 22.9 mmHg altered ventricular diameter from 2.77 +/- 0.49 cm to 3.17 +/- 0.67 cm (P < 0.05) and wall thickness from 0.83 +/- 0.09 to 0.75 +/- 0.09 cm (P < 0.05), LV mass estimated before (73.5 +/- 19.1 g) and after (78.3 +/- 26.4 g) hypertension was not significantly different. We demonstrate here for the first time that changes in LV dimensions induced by acute arterial hypertension do not modify LV mass values estimated by the M-mode electrocardiogram method.Departamento de Clínica Médica Faculdade de Medicina de Botucatu Universidade Estadual Paulista SPDepartamento de Clínica Médica Faculdade de Medicina de Botucatu Universidade Estadual Paulista SPUniversidade Estadual Paulista (UNESP)Matsubara, B. B. [UNESP]Bregagnollo, E. A. [UNESP]Tucci, P. J. [UNESP]2022-04-28T19:53:59Z2022-04-28T19:53:59Z1993-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article173-176Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.], v. 26, n. 2, p. 173-176, 1993.0100-879Xhttp://hdl.handle.net/11449/2239702-s2.0-0027539110Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.]info:eu-repo/semantics/openAccess2024-08-14T17:23:34Zoai:repositorio.unesp.br:11449/223970Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-14T17:23:34Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
title |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
spellingShingle |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. Matsubara, B. B. [UNESP] |
title_short |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
title_full |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
title_fullStr |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
title_full_unstemmed |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
title_sort |
Left ventricular mass estimated by M-mode echocardiogram is not altered by changes in cardiac shape and dimensions due to acute arterial hypertension. |
author |
Matsubara, B. B. [UNESP] |
author_facet |
Matsubara, B. B. [UNESP] Bregagnollo, E. A. [UNESP] Tucci, P. J. [UNESP] |
author_role |
author |
author2 |
Bregagnollo, E. A. [UNESP] Tucci, P. J. [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Matsubara, B. B. [UNESP] Bregagnollo, E. A. [UNESP] Tucci, P. J. [UNESP] |
description |
The effect of changes in left ventricular (LV) shape and dimensions due to acute arterial hypertension induced by mechanical obstruction of the aorta for 10 min on LV mass values estimated by M-mode echocardiogram was studied in 14 anesthetized dogs. Although the systolic pressure increased from 117.5 +/- 19.9 to 175.4 +/- 22.9 mmHg altered ventricular diameter from 2.77 +/- 0.49 cm to 3.17 +/- 0.67 cm (P < 0.05) and wall thickness from 0.83 +/- 0.09 to 0.75 +/- 0.09 cm (P < 0.05), LV mass estimated before (73.5 +/- 19.1 g) and after (78.3 +/- 26.4 g) hypertension was not significantly different. We demonstrate here for the first time that changes in LV dimensions induced by acute arterial hypertension do not modify LV mass values estimated by the M-mode electrocardiogram method. |
publishDate |
1993 |
dc.date.none.fl_str_mv |
1993-01-01 2022-04-28T19:53:59Z 2022-04-28T19:53:59Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.], v. 26, n. 2, p. 173-176, 1993. 0100-879X http://hdl.handle.net/11449/223970 2-s2.0-0027539110 |
identifier_str_mv |
Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.], v. 26, n. 2, p. 173-176, 1993. 0100-879X 2-s2.0-0027539110 |
url |
http://hdl.handle.net/11449/223970 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.] |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
173-176 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128171538644992 |