A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks

Detalhes bibliográficos
Autor(a) principal: Junior, Pedro Da Costa [UNESP]
Data de Publicação: 2019
Outros Autores: De Souza, Andre Nunes [UNESP], Martins, Andre Christovao Pio [UNESP]
Tipo de documento: Artigo de conferência
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1109/INDUSCON.2018.8627256
http://hdl.handle.net/11449/190167
Resumo: The post-failure impedance estimative method is one of the most used ways to locate faults in distribution systems. However, the presence of the distributed generation can degrade the precision of this kind of procedure. To get superior quality results, one can do the analysis using the electromagnetic transients of current or voltage since they are less affected by the presence of distributed generation. The electromagnetic time reversal method is more used in non-homogeneous environments to emphasize a wave at a point with excellent precision and locate sources that produce perturbations in a specific domain. The basic idea of the electromagnetic time reversal is to use the property of time reversibility of the wave equation. This property allows a reversion in the time domain of the transients, observed in strategic points of the system, to evidence the location of the related electromagnetic energy. This work presents an evaluation of the electromagnetic time reversal method (EMTR) for locating faults in underground distribution networks. This paper revised the time reversal method, and investigate its application in a virtual branched underground distribution system.
id UNSP_1cce4733087d1ad0a82ba5e5ab13b8fe
oai_identifier_str oai:repositorio.unesp.br:11449/190167
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networksElectromagnetic time reversalEMTRFault locationPower distribution faultsPower system transientsThe post-failure impedance estimative method is one of the most used ways to locate faults in distribution systems. However, the presence of the distributed generation can degrade the precision of this kind of procedure. To get superior quality results, one can do the analysis using the electromagnetic transients of current or voltage since they are less affected by the presence of distributed generation. The electromagnetic time reversal method is more used in non-homogeneous environments to emphasize a wave at a point with excellent precision and locate sources that produce perturbations in a specific domain. The basic idea of the electromagnetic time reversal is to use the property of time reversibility of the wave equation. This property allows a reversion in the time domain of the transients, observed in strategic points of the system, to evidence the location of the related electromagnetic energy. This work presents an evaluation of the electromagnetic time reversal method (EMTR) for locating faults in underground distribution networks. This paper revised the time reversal method, and investigate its application in a virtual branched underground distribution system.School of Engineering Sao Paulo State University (UNESP)School of Engineering Sao Paulo State University (UNESP)Universidade Estadual Paulista (Unesp)Junior, Pedro Da Costa [UNESP]De Souza, Andre Nunes [UNESP]Martins, Andre Christovao Pio [UNESP]2019-10-06T17:04:32Z2019-10-06T17:04:32Z2019-01-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject1349-1354http://dx.doi.org/10.1109/INDUSCON.2018.86272562018 13th IEEE International Conference on Industry Applications, INDUSCON 2018 - Proceedings, p. 1349-1354.http://hdl.handle.net/11449/19016710.1109/INDUSCON.2018.86272562-s2.0-8506250661284245472902535390000-0003-1495-633XScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2018 13th IEEE International Conference on Industry Applications, INDUSCON 2018 - Proceedingsinfo:eu-repo/semantics/openAccess2021-10-23T14:48:17Zoai:repositorio.unesp.br:11449/190167Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462021-10-23T14:48:17Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
title A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
spellingShingle A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
Junior, Pedro Da Costa [UNESP]
Electromagnetic time reversal
EMTR
Fault location
Power distribution faults
Power system transients
title_short A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
title_full A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
title_fullStr A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
title_full_unstemmed A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
title_sort A performance evaluation of electromagnetic time reversal method for locating faults in branched cable networks
author Junior, Pedro Da Costa [UNESP]
author_facet Junior, Pedro Da Costa [UNESP]
De Souza, Andre Nunes [UNESP]
Martins, Andre Christovao Pio [UNESP]
author_role author
author2 De Souza, Andre Nunes [UNESP]
Martins, Andre Christovao Pio [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Junior, Pedro Da Costa [UNESP]
De Souza, Andre Nunes [UNESP]
Martins, Andre Christovao Pio [UNESP]
dc.subject.por.fl_str_mv Electromagnetic time reversal
EMTR
Fault location
Power distribution faults
Power system transients
topic Electromagnetic time reversal
EMTR
Fault location
Power distribution faults
Power system transients
description The post-failure impedance estimative method is one of the most used ways to locate faults in distribution systems. However, the presence of the distributed generation can degrade the precision of this kind of procedure. To get superior quality results, one can do the analysis using the electromagnetic transients of current or voltage since they are less affected by the presence of distributed generation. The electromagnetic time reversal method is more used in non-homogeneous environments to emphasize a wave at a point with excellent precision and locate sources that produce perturbations in a specific domain. The basic idea of the electromagnetic time reversal is to use the property of time reversibility of the wave equation. This property allows a reversion in the time domain of the transients, observed in strategic points of the system, to evidence the location of the related electromagnetic energy. This work presents an evaluation of the electromagnetic time reversal method (EMTR) for locating faults in underground distribution networks. This paper revised the time reversal method, and investigate its application in a virtual branched underground distribution system.
publishDate 2019
dc.date.none.fl_str_mv 2019-10-06T17:04:32Z
2019-10-06T17:04:32Z
2019-01-25
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1109/INDUSCON.2018.8627256
2018 13th IEEE International Conference on Industry Applications, INDUSCON 2018 - Proceedings, p. 1349-1354.
http://hdl.handle.net/11449/190167
10.1109/INDUSCON.2018.8627256
2-s2.0-85062506612
8424547290253539
0000-0003-1495-633X
url http://dx.doi.org/10.1109/INDUSCON.2018.8627256
http://hdl.handle.net/11449/190167
identifier_str_mv 2018 13th IEEE International Conference on Industry Applications, INDUSCON 2018 - Proceedings, p. 1349-1354.
10.1109/INDUSCON.2018.8627256
2-s2.0-85062506612
8424547290253539
0000-0003-1495-633X
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2018 13th IEEE International Conference on Industry Applications, INDUSCON 2018 - Proceedings
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1349-1354
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803046545237475328