Resumo: | Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design. |
id |
UNSP_1cefa39ceb4e4fa9255fa0d3c0928b2d |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/64329 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angleFins (heat exchange)Flow of fluidsHeat exchangersOptimizationWaste heat utilizationFinned heat pipesHeat pipesHeat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.Universidade Estadual Paulista, GuaratinguetaUniversidade Estadual Paulista, GuaratinguetaUniversidade Estadual Paulista (Unesp)Tanisho, P. M. [UNESP]Murcia, N. [UNESP]Zanardi, M. A. [UNESP]2014-05-27T11:17:30Z2014-05-27T11:17:30Z1992-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject537-541ECOS '92 International Symposium, p. 537-541.http://hdl.handle.net/11449/643292-s2.0-0027005159Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengECOS '92 International Symposiuminfo:eu-repo/semantics/openAccess2021-10-23T21:37:55Zoai:repositorio.unesp.br:11449/64329Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:24:49.950015Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
title |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
spellingShingle |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle Tanisho, P. M. [UNESP] Fins (heat exchange) Flow of fluids Heat exchangers Optimization Waste heat utilization Finned heat pipes Heat pipes |
title_short |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
title_full |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
title_fullStr |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
title_full_unstemmed |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
title_sort |
Experimental analysis of heat recoveries with heat pipes operating in low inclination angle |
author |
Tanisho, P. M. [UNESP] |
author_facet |
Tanisho, P. M. [UNESP] Murcia, N. [UNESP] Zanardi, M. A. [UNESP] |
author_role |
author |
author2 |
Murcia, N. [UNESP] Zanardi, M. A. [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Tanisho, P. M. [UNESP] Murcia, N. [UNESP] Zanardi, M. A. [UNESP] |
dc.subject.por.fl_str_mv |
Fins (heat exchange) Flow of fluids Heat exchangers Optimization Waste heat utilization Finned heat pipes Heat pipes |
topic |
Fins (heat exchange) Flow of fluids Heat exchangers Optimization Waste heat utilization Finned heat pipes Heat pipes |
description |
Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design. |
publishDate |
1992 |
dc.date.none.fl_str_mv |
1992-12-01 2014-05-27T11:17:30Z 2014-05-27T11:17:30Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
ECOS '92 International Symposium, p. 537-541. http://hdl.handle.net/11449/64329 2-s2.0-0027005159 |
identifier_str_mv |
ECOS '92 International Symposium, p. 537-541. 2-s2.0-0027005159 |
url |
http://hdl.handle.net/11449/64329 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
ECOS '92 International Symposium |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
537-541 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128807043858432 |