Resumo: Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.
id UNSP_1cefa39ceb4e4fa9255fa0d3c0928b2d
oai_identifier_str oai:repositorio.unesp.br:11449/64329
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Experimental analysis of heat recoveries with heat pipes operating in low inclination angleFins (heat exchange)Flow of fluidsHeat exchangersOptimizationWaste heat utilizationFinned heat pipesHeat pipesHeat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.Universidade Estadual Paulista, GuaratinguetaUniversidade Estadual Paulista, GuaratinguetaUniversidade Estadual Paulista (Unesp)Tanisho, P. M. [UNESP]Murcia, N. [UNESP]Zanardi, M. A. [UNESP]2014-05-27T11:17:30Z2014-05-27T11:17:30Z1992-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject537-541ECOS '92 International Symposium, p. 537-541.http://hdl.handle.net/11449/643292-s2.0-0027005159Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengECOS '92 International Symposiuminfo:eu-repo/semantics/openAccess2021-10-23T21:37:55Zoai:repositorio.unesp.br:11449/64329Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:24:49.950015Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
title Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
spellingShingle Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
Tanisho, P. M. [UNESP]
Fins (heat exchange)
Flow of fluids
Heat exchangers
Optimization
Waste heat utilization
Finned heat pipes
Heat pipes
title_short Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
title_full Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
title_fullStr Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
title_full_unstemmed Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
title_sort Experimental analysis of heat recoveries with heat pipes operating in low inclination angle
author Tanisho, P. M. [UNESP]
author_facet Tanisho, P. M. [UNESP]
Murcia, N. [UNESP]
Zanardi, M. A. [UNESP]
author_role author
author2 Murcia, N. [UNESP]
Zanardi, M. A. [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Tanisho, P. M. [UNESP]
Murcia, N. [UNESP]
Zanardi, M. A. [UNESP]
dc.subject.por.fl_str_mv Fins (heat exchange)
Flow of fluids
Heat exchangers
Optimization
Waste heat utilization
Finned heat pipes
Heat pipes
topic Fins (heat exchange)
Flow of fluids
Heat exchangers
Optimization
Waste heat utilization
Finned heat pipes
Heat pipes
description Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.
publishDate 1992
dc.date.none.fl_str_mv 1992-12-01
2014-05-27T11:17:30Z
2014-05-27T11:17:30Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv ECOS '92 International Symposium, p. 537-541.
http://hdl.handle.net/11449/64329
2-s2.0-0027005159
identifier_str_mv ECOS '92 International Symposium, p. 537-541.
2-s2.0-0027005159
url http://hdl.handle.net/11449/64329
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv ECOS '92 International Symposium
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 537-541
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128807043858432