Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/S0100-40422012000300017 http://hdl.handle.net/11449/8032 |
Resumo: | The bioassay, first order derivative UV spectrophotometry and chromatographic methods for assaying fluconazole capsules were compared. They have shown great advantages over the earlier published methods. Using the first order derivative, the UV spectrophotometry method does not suffer interference of excipients. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. All methods were linear and reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads. |
id |
UNSP_1ef64045ecff7d4b3d77ca1596fc56f7 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/8032 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsulesfluconazoleliquid chromatographybioassayThe bioassay, first order derivative UV spectrophotometry and chromatographic methods for assaying fluconazole capsules were compared. They have shown great advantages over the earlier published methods. Using the first order derivative, the UV spectrophotometry method does not suffer interference of excipients. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. All methods were linear and reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.Programa de Apoio ao Desenvolvimento Científico da Faculdade de Ciências Farmacêuticas da UNESP (PADC)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Universidade Estadual Paulista Faculdade de Ciências Farmacêuticas Departamento de Fármacos e medicamentosUniversidade Federal de Minas Gerais Faculdade de Farmácia Departamento de Produtos FarmacêuticosUniversidade Estadual Paulista Faculdade de Ciências Farmacêuticas Departamento de Fármacos e medicamentosSociedade Brasileira de QuímicaUniversidade Estadual Paulista (Unesp)Universidade Federal de Minas Gerais (UFMG)Corrêa, Josilene Chaves Ruela [UNESP]Chin, Chung Man [UNESP]Salgado, Hérida Regina Nunes [UNESP]Vianna-Soares, Cristina Duarte2014-05-20T13:25:23Z2014-05-20T13:25:23Z2012-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article530-534application/pdfhttp://dx.doi.org/10.1590/S0100-40422012000300017Química Nova. Sociedade Brasileira de Química, v. 35, n. 3, p. 530-534, 2012.0100-4042http://hdl.handle.net/11449/803210.1590/S0100-40422012000300017S0100-40422012000300017WOS:000303071700017S0100-40422012000300017.pdf97343336079754130000-0003-4141-0455SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengQuímica Nova0.6460,255info:eu-repo/semantics/openAccess2024-06-24T13:45:28Zoai:repositorio.unesp.br:11449/8032Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:59:29.836776Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
title |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
spellingShingle |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules Corrêa, Josilene Chaves Ruela [UNESP] fluconazole liquid chromatography bioassay |
title_short |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
title_full |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
title_fullStr |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
title_full_unstemmed |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
title_sort |
Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules |
author |
Corrêa, Josilene Chaves Ruela [UNESP] |
author_facet |
Corrêa, Josilene Chaves Ruela [UNESP] Chin, Chung Man [UNESP] Salgado, Hérida Regina Nunes [UNESP] Vianna-Soares, Cristina Duarte |
author_role |
author |
author2 |
Chin, Chung Man [UNESP] Salgado, Hérida Regina Nunes [UNESP] Vianna-Soares, Cristina Duarte |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade Federal de Minas Gerais (UFMG) |
dc.contributor.author.fl_str_mv |
Corrêa, Josilene Chaves Ruela [UNESP] Chin, Chung Man [UNESP] Salgado, Hérida Regina Nunes [UNESP] Vianna-Soares, Cristina Duarte |
dc.subject.por.fl_str_mv |
fluconazole liquid chromatography bioassay |
topic |
fluconazole liquid chromatography bioassay |
description |
The bioassay, first order derivative UV spectrophotometry and chromatographic methods for assaying fluconazole capsules were compared. They have shown great advantages over the earlier published methods. Using the first order derivative, the UV spectrophotometry method does not suffer interference of excipients. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. All methods were linear and reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01-01 2014-05-20T13:25:23Z 2014-05-20T13:25:23Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0100-40422012000300017 Química Nova. Sociedade Brasileira de Química, v. 35, n. 3, p. 530-534, 2012. 0100-4042 http://hdl.handle.net/11449/8032 10.1590/S0100-40422012000300017 S0100-40422012000300017 WOS:000303071700017 S0100-40422012000300017.pdf 9734333607975413 0000-0003-4141-0455 |
url |
http://dx.doi.org/10.1590/S0100-40422012000300017 http://hdl.handle.net/11449/8032 |
identifier_str_mv |
Química Nova. Sociedade Brasileira de Química, v. 35, n. 3, p. 530-534, 2012. 0100-4042 10.1590/S0100-40422012000300017 S0100-40422012000300017 WOS:000303071700017 S0100-40422012000300017.pdf 9734333607975413 0000-0003-4141-0455 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Química Nova 0.646 0,255 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
530-534 application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128590304247808 |