Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin

Detalhes bibliográficos
Autor(a) principal: Ferreira Jassé, Fernanda
Data de Publicação: 2013
Outros Autores: Borges, Carlos Henrique Braga, Tonetto, Mateus Rodrigues, Rastelli, Alessandra Nara de Souza, Bagnato, Vanderlei Salvador, Campos, Edson Alves, Santos, Reidson Stanley Soares, Bandeca, Matheus Coêlho, Saad, José Roberto Cury [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.jaypeejournals.com/eJournals/Abstract.aspx?id=5496&AID=24&num=18
http://hdl.handle.net/11449/125892
Resumo: Objective: This study aims to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (HV) of a nanofilled (Filtek™ Z-250, 3M) and a microhybrid (Filtek™Supreme-XT, 3M) composite resin. Materials and methods: Eight disk-shaped specimens (4 mm diameter × 2 mm thick, ISO 4049) of each material were prepared for each test. Composites were inserted into single increment in a metallic matrix and light-cured for 40 seconds. VH readings were performed for each specimen at predetermined intervals: immediately after polymerization (control), 1, 2, 3, 7, 14, 21, 30 and 180 days. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37°C. For DC (%), specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer. Results: Student t-test showed that there was no difference between the resins for DC (p = 0.252). ANOVA analysis revealed that Z-250 VH means were all greater than S-XT, for both top and bottom surfaces, whatever the storage-period in artificial saliva (p < 0.001). After 180 days of storage, the hardness obtained for S-XT was similar with that at the baseline, for both top and bottom surfaces. While for Z-250 hardness was not significantly different from baseline only for top surface, but there was a significant decrease observed in hardness for bottom surface. Conclusion: The materials tested showed no evidence of hydrolytic degradation in a significant way, in a 6-month storagetime in artificial saliva. Nanofilled resin presents a monomer conversion comparable to the conventional microhybrid.
id UNSP_21080b4214954e5b4b4c8e35124cb695
oai_identifier_str oai:repositorio.unesp.br:11449/125892
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resinComposite resinsHardness testsArtificial salivaFourier transform infrared spectroscopyObjective: This study aims to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (HV) of a nanofilled (Filtek™ Z-250, 3M) and a microhybrid (Filtek™Supreme-XT, 3M) composite resin. Materials and methods: Eight disk-shaped specimens (4 mm diameter × 2 mm thick, ISO 4049) of each material were prepared for each test. Composites were inserted into single increment in a metallic matrix and light-cured for 40 seconds. VH readings were performed for each specimen at predetermined intervals: immediately after polymerization (control), 1, 2, 3, 7, 14, 21, 30 and 180 days. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37°C. For DC (%), specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer. Results: Student t-test showed that there was no difference between the resins for DC (p = 0.252). ANOVA analysis revealed that Z-250 VH means were all greater than S-XT, for both top and bottom surfaces, whatever the storage-period in artificial saliva (p < 0.001). After 180 days of storage, the hardness obtained for S-XT was similar with that at the baseline, for both top and bottom surfaces. While for Z-250 hardness was not significantly different from baseline only for top surface, but there was a significant decrease observed in hardness for bottom surface. Conclusion: The materials tested showed no evidence of hydrolytic degradation in a significant way, in a 6-month storagetime in artificial saliva. Nanofilled resin presents a monomer conversion comparable to the conventional microhybrid.Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Odontologia Restauradora, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá 1680 3 andar sala 313, Centro, CEP 14801-903, SP, BrasilUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Odontologia Restauradora, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá 1680 3 andar sala 313, Centro, CEP 14801-903, SP, BrasilUniversidade Estadual Paulista (Unesp)Ferreira Jassé, FernandaBorges, Carlos Henrique BragaTonetto, Mateus RodriguesRastelli, Alessandra Nara de SouzaBagnato, Vanderlei SalvadorCampos, Edson AlvesSantos, Reidson Stanley SoaresBandeca, Matheus CoêlhoSaad, José Roberto Cury [UNESP]2015-08-06T16:13:23Z2015-08-06T16:13:23Z2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article876-882http://www.jaypeejournals.com/eJournals/Abstract.aspx?id=5496&AID=24&num=18The Journal of Contemporary Dental Practice, v. 14, n. 5, p. 876-882, 2013.1526-3711http://hdl.handle.net/11449/12589210.5005/jp-journals-10024-14191541792949750106691496952621339359045870555486544947860249518663Currículo Lattesreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengThe Journal of Contemporary Dental Practice0,263info:eu-repo/semantics/openAccess2021-10-23T21:56:24Zoai:repositorio.unesp.br:11449/125892Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:42:57.297612Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
title Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
spellingShingle Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
Ferreira Jassé, Fernanda
Composite resins
Hardness tests
Artificial saliva
Fourier transform infrared spectroscopy
title_short Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
title_full Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
title_fullStr Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
title_full_unstemmed Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
title_sort Long-term surface hardness and monomer conversion of a nonofilled and a microhybrid composite resin
author Ferreira Jassé, Fernanda
author_facet Ferreira Jassé, Fernanda
Borges, Carlos Henrique Braga
Tonetto, Mateus Rodrigues
Rastelli, Alessandra Nara de Souza
Bagnato, Vanderlei Salvador
Campos, Edson Alves
Santos, Reidson Stanley Soares
Bandeca, Matheus Coêlho
Saad, José Roberto Cury [UNESP]
author_role author
author2 Borges, Carlos Henrique Braga
Tonetto, Mateus Rodrigues
Rastelli, Alessandra Nara de Souza
Bagnato, Vanderlei Salvador
Campos, Edson Alves
Santos, Reidson Stanley Soares
Bandeca, Matheus Coêlho
Saad, José Roberto Cury [UNESP]
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Ferreira Jassé, Fernanda
Borges, Carlos Henrique Braga
Tonetto, Mateus Rodrigues
Rastelli, Alessandra Nara de Souza
Bagnato, Vanderlei Salvador
Campos, Edson Alves
Santos, Reidson Stanley Soares
Bandeca, Matheus Coêlho
Saad, José Roberto Cury [UNESP]
dc.subject.por.fl_str_mv Composite resins
Hardness tests
Artificial saliva
Fourier transform infrared spectroscopy
topic Composite resins
Hardness tests
Artificial saliva
Fourier transform infrared spectroscopy
description Objective: This study aims to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (HV) of a nanofilled (Filtek™ Z-250, 3M) and a microhybrid (Filtek™Supreme-XT, 3M) composite resin. Materials and methods: Eight disk-shaped specimens (4 mm diameter × 2 mm thick, ISO 4049) of each material were prepared for each test. Composites were inserted into single increment in a metallic matrix and light-cured for 40 seconds. VH readings were performed for each specimen at predetermined intervals: immediately after polymerization (control), 1, 2, 3, 7, 14, 21, 30 and 180 days. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37°C. For DC (%), specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer. Results: Student t-test showed that there was no difference between the resins for DC (p = 0.252). ANOVA analysis revealed that Z-250 VH means were all greater than S-XT, for both top and bottom surfaces, whatever the storage-period in artificial saliva (p < 0.001). After 180 days of storage, the hardness obtained for S-XT was similar with that at the baseline, for both top and bottom surfaces. While for Z-250 hardness was not significantly different from baseline only for top surface, but there was a significant decrease observed in hardness for bottom surface. Conclusion: The materials tested showed no evidence of hydrolytic degradation in a significant way, in a 6-month storagetime in artificial saliva. Nanofilled resin presents a monomer conversion comparable to the conventional microhybrid.
publishDate 2013
dc.date.none.fl_str_mv 2013
2015-08-06T16:13:23Z
2015-08-06T16:13:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.jaypeejournals.com/eJournals/Abstract.aspx?id=5496&AID=24&num=18
The Journal of Contemporary Dental Practice, v. 14, n. 5, p. 876-882, 2013.
1526-3711
http://hdl.handle.net/11449/125892
10.5005/jp-journals-10024-1419
1541792949750106
6914969526213393
5904587055548654
4947860249518663
url http://www.jaypeejournals.com/eJournals/Abstract.aspx?id=5496&AID=24&num=18
http://hdl.handle.net/11449/125892
identifier_str_mv The Journal of Contemporary Dental Practice, v. 14, n. 5, p. 876-882, 2013.
1526-3711
10.5005/jp-journals-10024-1419
1541792949750106
6914969526213393
5904587055548654
4947860249518663
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv The Journal of Contemporary Dental Practice
0,263
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 876-882
dc.source.none.fl_str_mv Currículo Lattes
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129453954433024