COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS

Detalhes bibliográficos
Autor(a) principal: Fazio, Alirio [UNESP]
Data de Publicação: 2011
Outros Autores: Sampaio, Leonardo P. [UNESP], Brito, Moacyr A. G. de [UNESP], A e Melo, Guilherme [UNESP], Canesin, Carlos A. [UNESP], IEEE
Tipo de documento: Artigo de conferência
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/196118
Resumo: This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup.
id UNSP_219b9ae92b820d6d279deac1d1cd39e4
oai_identifier_str oai:repositorio.unesp.br:11449/196118
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITSModern Power TheoriesReactive PowerNon-linear LoadsUnbalanced CircuitsThree-phase Four-wire CircuitsMeasurement Errors for Reactive EnergyThis paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)ELETROBRAS-CEAL (RD Program)Sao Paulo State Univ, UNESP, Power Elect Lab, Dept Elect Engn, Ave Prof Jose Carlos Rossi 1370, BR-15385000 Ilha Solteira, SP, BrazilSao Paulo State Univ, UNESP, Power Elect Lab, Dept Elect Engn, Ave Prof Jose Carlos Rossi 1370, BR-15385000 Ilha Solteira, SP, BrazilIeeeUniversidade Estadual Paulista (Unesp)Fazio, Alirio [UNESP]Sampaio, Leonardo P. [UNESP]Brito, Moacyr A. G. de [UNESP]A e Melo, Guilherme [UNESP]Canesin, Carlos A. [UNESP]IEEE2020-12-10T19:33:59Z2020-12-10T19:33:59Z2011-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject494-501Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 494-501, 2011.2175-8603http://hdl.handle.net/11449/196118WOS:000395311200077Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengXi Brazilian Power Electronics Conference (cobep 2011)info:eu-repo/semantics/openAccess2021-10-23T03:22:16Zoai:repositorio.unesp.br:11449/196118Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462021-10-23T03:22:16Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
title COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
spellingShingle COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
Fazio, Alirio [UNESP]
Modern Power Theories
Reactive Power
Non-linear Loads
Unbalanced Circuits
Three-phase Four-wire Circuits
Measurement Errors for Reactive Energy
title_short COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
title_full COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
title_fullStr COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
title_full_unstemmed COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
title_sort COMPARATIVE ANALYSIS FOR REACTIVE ENERGY MEASUREMENT METHODOLOGIES, UNDER NON-SINUSOIDAL CONDITIONS IN THREE-PHASE FOUR-WIRE CIRCUITS
author Fazio, Alirio [UNESP]
author_facet Fazio, Alirio [UNESP]
Sampaio, Leonardo P. [UNESP]
Brito, Moacyr A. G. de [UNESP]
A e Melo, Guilherme [UNESP]
Canesin, Carlos A. [UNESP]
IEEE
author_role author
author2 Sampaio, Leonardo P. [UNESP]
Brito, Moacyr A. G. de [UNESP]
A e Melo, Guilherme [UNESP]
Canesin, Carlos A. [UNESP]
IEEE
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Fazio, Alirio [UNESP]
Sampaio, Leonardo P. [UNESP]
Brito, Moacyr A. G. de [UNESP]
A e Melo, Guilherme [UNESP]
Canesin, Carlos A. [UNESP]
IEEE
dc.subject.por.fl_str_mv Modern Power Theories
Reactive Power
Non-linear Loads
Unbalanced Circuits
Three-phase Four-wire Circuits
Measurement Errors for Reactive Energy
topic Modern Power Theories
Reactive Power
Non-linear Loads
Unbalanced Circuits
Three-phase Four-wire Circuits
Measurement Errors for Reactive Energy
description This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
2020-12-10T19:33:59Z
2020-12-10T19:33:59Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 494-501, 2011.
2175-8603
http://hdl.handle.net/11449/196118
WOS:000395311200077
identifier_str_mv Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 494-501, 2011.
2175-8603
WOS:000395311200077
url http://hdl.handle.net/11449/196118
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Xi Brazilian Power Electronics Conference (cobep 2011)
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 494-501
dc.publisher.none.fl_str_mv Ieee
publisher.none.fl_str_mv Ieee
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799964478780997632