Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/1678-5150-PVB-5032 http://hdl.handle.net/11449/176320 |
Resumo: | The automated hematology counter ABX Micros 60 ESX (Horiba Medical 2012) is veterinary hematology analyzer multi-species that carries 50 counts per hour releases 18 blood parameters, in addition to graphical representations (histograms) for leukocytes, erythrocytes and platelets. The objective of this study is to evaluate the performance of the apparatus with respect to linearity and carryover through commercial control and blood samples from the routine of Veterinary Clinical Pathology Laboratory. According to results we can say that this device has excellent linearity coefficient (r2=0.99) in leukocyte parameters, erythrocytes and platelets during that time dilutions. Regarding the carryover was excellent device performance, however, was not in conformity values in the parameters of MCHC and VPM in one of the methodologies made that can be justified by the limited formula that does not consider the equipment characteristics. |
id |
UNSP_2cf8cfc167515a02a27f780d312644fb |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/176320 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60Linearidade e carryover do contador hematológico Horiba® Abx Micros ESV 60Automated hematologyCell blood counterCounter Horiba® Abx Micros ESV 60PerformanceVeterinaryThe automated hematology counter ABX Micros 60 ESX (Horiba Medical 2012) is veterinary hematology analyzer multi-species that carries 50 counts per hour releases 18 blood parameters, in addition to graphical representations (histograms) for leukocytes, erythrocytes and platelets. The objective of this study is to evaluate the performance of the apparatus with respect to linearity and carryover through commercial control and blood samples from the routine of Veterinary Clinical Pathology Laboratory. According to results we can say that this device has excellent linearity coefficient (r2=0.99) in leukocyte parameters, erythrocytes and platelets during that time dilutions. Regarding the carryover was excellent device performance, however, was not in conformity values in the parameters of MCHC and VPM in one of the methodologies made that can be justified by the limited formula that does not consider the equipment characteristics.Laboratório de Patologia Clínica Veterinária Hospital Veterinário Governador 'Laudo Natel' Universidade Estadual Paulista (Unesp) Faculdade de Ciências Agrárias e Veterinárias (FCAV), Via de Acesso Rodovia Paulo Donato Castellane s/n Km 5Laboratório de Patologia Clínica Veterinária Hospital Veterinário Governador 'Laudo Natel' Universidade Estadual Paulista (Unesp) Faculdade de Ciências Agrárias e Veterinárias (FCAV), Via de Acesso Rodovia Paulo Donato Castellane s/n Km 5Universidade Estadual Paulista (Unesp)Cruz, Nathan R.N. [UNESP]Yamazaki, Matheus A. [UNESP]Martinelli, Amanda E. [UNESP]Martinato, Fernanda [UNESP]Santana, Aureo E. [UNESP]2018-12-11T17:20:07Z2018-12-11T17:20:07Z2018-02-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article345-349application/pdfhttp://dx.doi.org/10.1590/1678-5150-PVB-5032Pesquisa Veterinaria Brasileira, v. 38, n. 2, p. 345-349, 2018.1678-51500100-736Xhttp://hdl.handle.net/11449/17632010.1590/1678-5150-PVB-5032S0100-736X20180002003452-s2.0-85046864611S0100-736X2018000200345.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporPesquisa Veterinaria Brasileirainfo:eu-repo/semantics/openAccess2024-06-07T13:02:16Zoai:repositorio.unesp.br:11449/176320Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:58:37.686295Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 Linearidade e carryover do contador hematológico Horiba® Abx Micros ESV 60 |
title |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 |
spellingShingle |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 Cruz, Nathan R.N. [UNESP] Automated hematology Cell blood counter Counter Horiba® Abx Micros ESV 60 Performance Veterinary |
title_short |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 |
title_full |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 |
title_fullStr |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 |
title_full_unstemmed |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 |
title_sort |
Linearity and carryover of automated hematology counter Horiba® Abx Micros ESV 60 |
author |
Cruz, Nathan R.N. [UNESP] |
author_facet |
Cruz, Nathan R.N. [UNESP] Yamazaki, Matheus A. [UNESP] Martinelli, Amanda E. [UNESP] Martinato, Fernanda [UNESP] Santana, Aureo E. [UNESP] |
author_role |
author |
author2 |
Yamazaki, Matheus A. [UNESP] Martinelli, Amanda E. [UNESP] Martinato, Fernanda [UNESP] Santana, Aureo E. [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Cruz, Nathan R.N. [UNESP] Yamazaki, Matheus A. [UNESP] Martinelli, Amanda E. [UNESP] Martinato, Fernanda [UNESP] Santana, Aureo E. [UNESP] |
dc.subject.por.fl_str_mv |
Automated hematology Cell blood counter Counter Horiba® Abx Micros ESV 60 Performance Veterinary |
topic |
Automated hematology Cell blood counter Counter Horiba® Abx Micros ESV 60 Performance Veterinary |
description |
The automated hematology counter ABX Micros 60 ESX (Horiba Medical 2012) is veterinary hematology analyzer multi-species that carries 50 counts per hour releases 18 blood parameters, in addition to graphical representations (histograms) for leukocytes, erythrocytes and platelets. The objective of this study is to evaluate the performance of the apparatus with respect to linearity and carryover through commercial control and blood samples from the routine of Veterinary Clinical Pathology Laboratory. According to results we can say that this device has excellent linearity coefficient (r2=0.99) in leukocyte parameters, erythrocytes and platelets during that time dilutions. Regarding the carryover was excellent device performance, however, was not in conformity values in the parameters of MCHC and VPM in one of the methodologies made that can be justified by the limited formula that does not consider the equipment characteristics. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-12-11T17:20:07Z 2018-12-11T17:20:07Z 2018-02-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/1678-5150-PVB-5032 Pesquisa Veterinaria Brasileira, v. 38, n. 2, p. 345-349, 2018. 1678-5150 0100-736X http://hdl.handle.net/11449/176320 10.1590/1678-5150-PVB-5032 S0100-736X2018000200345 2-s2.0-85046864611 S0100-736X2018000200345.pdf |
url |
http://dx.doi.org/10.1590/1678-5150-PVB-5032 http://hdl.handle.net/11449/176320 |
identifier_str_mv |
Pesquisa Veterinaria Brasileira, v. 38, n. 2, p. 345-349, 2018. 1678-5150 0100-736X 10.1590/1678-5150-PVB-5032 S0100-736X2018000200345 2-s2.0-85046864611 S0100-736X2018000200345.pdf |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Pesquisa Veterinaria Brasileira |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
345-349 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128880542744576 |