Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes

Detalhes bibliográficos
Autor(a) principal: Cravo, JCM [UNESP]
Data de Publicação: 2009
Outros Autores: Fiorelli, J, Lahr, FAR, Fonseca, R da [UNESP], Cruz, VC da [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S1516-635X2009000400002
http://hdl.handle.net/11449/26429
Resumo: This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.
id UNSP_326069df45ca0917f175681bc6535688
oai_identifier_str oai:repositorio.unesp.br:11449/26429
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypesBroiler house environmentrecycled tilesthermal comfortThis study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.Universidade Estadual Paulista Júlio de Mesquita FilhoUniversidade de São Paulo Faculdade de Zootecnia e Engenharia de AlimentoUniversidade de São Paulo Escola de Engenharia de São CarlosUniversidade Estadual Paulista Júlio de Mesquita FilhoFundação APINCO de Ciência e Tecnologia AvícolasUniversidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Cravo, JCM [UNESP]Fiorelli, JLahr, FARFonseca, R da [UNESP]Cruz, VC da [UNESP]2014-05-20T15:07:15Z2014-05-20T15:07:15Z2009-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article219-224application/pdfhttp://dx.doi.org/10.1590/S1516-635X2009000400002Revista Brasileira de Ciência Avícola. Fundação APINCO de Ciência e Tecnologia Avícolas, v. 11, n. 4, p. 219-224, 2009.1516-635Xhttp://hdl.handle.net/11449/2642910.1590/S1516-635X2009000400002S1516-635X2009000400002WOS:000276475000002S1516-635X2009000400002.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengRevista Brasileira de Ciência Avícola0.463info:eu-repo/semantics/openAccess2024-01-05T06:21:42Zoai:repositorio.unesp.br:11449/26429Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:09:27.211206Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
title Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
spellingShingle Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
Cravo, JCM [UNESP]
Broiler house environment
recycled tiles
thermal comfort
title_short Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
title_full Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
title_fullStr Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
title_full_unstemmed Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
title_sort Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes
author Cravo, JCM [UNESP]
author_facet Cravo, JCM [UNESP]
Fiorelli, J
Lahr, FAR
Fonseca, R da [UNESP]
Cruz, VC da [UNESP]
author_role author
author2 Fiorelli, J
Lahr, FAR
Fonseca, R da [UNESP]
Cruz, VC da [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Cravo, JCM [UNESP]
Fiorelli, J
Lahr, FAR
Fonseca, R da [UNESP]
Cruz, VC da [UNESP]
dc.subject.por.fl_str_mv Broiler house environment
recycled tiles
thermal comfort
topic Broiler house environment
recycled tiles
thermal comfort
description This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.
publishDate 2009
dc.date.none.fl_str_mv 2009-12-01
2014-05-20T15:07:15Z
2014-05-20T15:07:15Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1516-635X2009000400002
Revista Brasileira de Ciência Avícola. Fundação APINCO de Ciência e Tecnologia Avícolas, v. 11, n. 4, p. 219-224, 2009.
1516-635X
http://hdl.handle.net/11449/26429
10.1590/S1516-635X2009000400002
S1516-635X2009000400002
WOS:000276475000002
S1516-635X2009000400002.pdf
url http://dx.doi.org/10.1590/S1516-635X2009000400002
http://hdl.handle.net/11449/26429
identifier_str_mv Revista Brasileira de Ciência Avícola. Fundação APINCO de Ciência e Tecnologia Avícolas, v. 11, n. 4, p. 219-224, 2009.
1516-635X
10.1590/S1516-635X2009000400002
S1516-635X2009000400002
WOS:000276475000002
S1516-635X2009000400002.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Revista Brasileira de Ciência Avícola
0.463
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 219-224
application/pdf
dc.publisher.none.fl_str_mv Fundação APINCO de Ciência e Tecnologia Avícolas
publisher.none.fl_str_mv Fundação APINCO de Ciência e Tecnologia Avícolas
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129398233104384