Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/0103-6440201801916 http://hdl.handle.net/11449/188393 |
Resumo: | The aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups. |
id |
UNSP_3266f8c375b23352ba71afcb84f473dd |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/188393 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systemsCAD/CAMDental solderingMarginal adaptationMisfitWeldingThe aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Department of Dental Materials and Prosthodontics Araçatuba Dental School UNESP – Universidade Estadual PaulistaPró-Reitoria de Pesquisa e Pós-graduação (PRPPG) USC-Universidade do Sagrado CoraçãoDepartment of Dental Materials and Prosthodontics Araçatuba Dental School UNESP – Universidade Estadual PaulistaFAPESP: 2011/19150-7Universidade Estadual Paulista (Unesp)USC-Universidade do Sagrado CoraçãoPellizzer, Eduardo Piza [UNESP]de Mello, Caroline Cantieri [UNESP]Gomes, Jéssica Marcela de Luna [UNESP]Santiago Júnior, Joel FerreiraLemos, Cleidiel Aparecido Araújo [UNESP]Verri, Fellippo Ramos [UNESP]2019-10-06T16:06:34Z2019-10-06T16:06:34Z2018-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article342-346application/pdfhttp://dx.doi.org/10.1590/0103-6440201801916Brazilian Dental Journal, v. 29, n. 4, p. 342-346, 2018.1806-47600103-6440http://hdl.handle.net/11449/18839310.1590/0103-6440201801916S0103-644020180004003422-s2.0-85056982486S0103-64402018000400342.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journalinfo:eu-repo/semantics/openAccess2024-09-19T14:50:48Zoai:repositorio.unesp.br:11449/188393Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-19T14:50:48Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
title |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
spellingShingle |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems Pellizzer, Eduardo Piza [UNESP] CAD/CAM Dental soldering Marginal adaptation Misfit Welding |
title_short |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
title_full |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
title_fullStr |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
title_full_unstemmed |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
title_sort |
Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems |
author |
Pellizzer, Eduardo Piza [UNESP] |
author_facet |
Pellizzer, Eduardo Piza [UNESP] de Mello, Caroline Cantieri [UNESP] Gomes, Jéssica Marcela de Luna [UNESP] Santiago Júnior, Joel Ferreira Lemos, Cleidiel Aparecido Araújo [UNESP] Verri, Fellippo Ramos [UNESP] |
author_role |
author |
author2 |
de Mello, Caroline Cantieri [UNESP] Gomes, Jéssica Marcela de Luna [UNESP] Santiago Júnior, Joel Ferreira Lemos, Cleidiel Aparecido Araújo [UNESP] Verri, Fellippo Ramos [UNESP] |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) USC-Universidade do Sagrado Coração |
dc.contributor.author.fl_str_mv |
Pellizzer, Eduardo Piza [UNESP] de Mello, Caroline Cantieri [UNESP] Gomes, Jéssica Marcela de Luna [UNESP] Santiago Júnior, Joel Ferreira Lemos, Cleidiel Aparecido Araújo [UNESP] Verri, Fellippo Ramos [UNESP] |
dc.subject.por.fl_str_mv |
CAD/CAM Dental soldering Marginal adaptation Misfit Welding |
topic |
CAD/CAM Dental soldering Marginal adaptation Misfit Welding |
description |
The aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-07-01 2019-10-06T16:06:34Z 2019-10-06T16:06:34Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/0103-6440201801916 Brazilian Dental Journal, v. 29, n. 4, p. 342-346, 2018. 1806-4760 0103-6440 http://hdl.handle.net/11449/188393 10.1590/0103-6440201801916 S0103-64402018000400342 2-s2.0-85056982486 S0103-64402018000400342.pdf |
url |
http://dx.doi.org/10.1590/0103-6440201801916 http://hdl.handle.net/11449/188393 |
identifier_str_mv |
Brazilian Dental Journal, v. 29, n. 4, p. 342-346, 2018. 1806-4760 0103-6440 10.1590/0103-6440201801916 S0103-64402018000400342 2-s2.0-85056982486 S0103-64402018000400342.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian Dental Journal |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
342-346 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546399581601792 |