Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems

Detalhes bibliográficos
Autor(a) principal: Pellizzer, Eduardo Piza [UNESP]
Data de Publicação: 2018
Outros Autores: de Mello, Caroline Cantieri [UNESP], Gomes, Jéssica Marcela de Luna [UNESP], Santiago Júnior, Joel Ferreira, Lemos, Cleidiel Aparecido Araújo [UNESP], Verri, Fellippo Ramos [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/0103-6440201801916
http://hdl.handle.net/11449/188393
Resumo: The aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups.
id UNSP_3266f8c375b23352ba71afcb84f473dd
oai_identifier_str oai:repositorio.unesp.br:11449/188393
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systemsCAD/CAMDental solderingMarginal adaptationMisfitWeldingThe aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Department of Dental Materials and Prosthodontics Araçatuba Dental School UNESP – Universidade Estadual PaulistaPró-Reitoria de Pesquisa e Pós-graduação (PRPPG) USC-Universidade do Sagrado CoraçãoDepartment of Dental Materials and Prosthodontics Araçatuba Dental School UNESP – Universidade Estadual PaulistaFAPESP: 2011/19150-7Universidade Estadual Paulista (Unesp)USC-Universidade do Sagrado CoraçãoPellizzer, Eduardo Piza [UNESP]de Mello, Caroline Cantieri [UNESP]Gomes, Jéssica Marcela de Luna [UNESP]Santiago Júnior, Joel FerreiraLemos, Cleidiel Aparecido Araújo [UNESP]Verri, Fellippo Ramos [UNESP]2019-10-06T16:06:34Z2019-10-06T16:06:34Z2018-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article342-346application/pdfhttp://dx.doi.org/10.1590/0103-6440201801916Brazilian Dental Journal, v. 29, n. 4, p. 342-346, 2018.1806-47600103-6440http://hdl.handle.net/11449/18839310.1590/0103-6440201801916S0103-644020180004003422-s2.0-85056982486S0103-64402018000400342.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journalinfo:eu-repo/semantics/openAccess2024-09-19T14:50:48Zoai:repositorio.unesp.br:11449/188393Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-19T14:50:48Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
title Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
spellingShingle Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
Pellizzer, Eduardo Piza [UNESP]
CAD/CAM
Dental soldering
Marginal adaptation
Misfit
Welding
title_short Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
title_full Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
title_fullStr Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
title_full_unstemmed Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
title_sort Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM systems
author Pellizzer, Eduardo Piza [UNESP]
author_facet Pellizzer, Eduardo Piza [UNESP]
de Mello, Caroline Cantieri [UNESP]
Gomes, Jéssica Marcela de Luna [UNESP]
Santiago Júnior, Joel Ferreira
Lemos, Cleidiel Aparecido Araújo [UNESP]
Verri, Fellippo Ramos [UNESP]
author_role author
author2 de Mello, Caroline Cantieri [UNESP]
Gomes, Jéssica Marcela de Luna [UNESP]
Santiago Júnior, Joel Ferreira
Lemos, Cleidiel Aparecido Araújo [UNESP]
Verri, Fellippo Ramos [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
USC-Universidade do Sagrado Coração
dc.contributor.author.fl_str_mv Pellizzer, Eduardo Piza [UNESP]
de Mello, Caroline Cantieri [UNESP]
Gomes, Jéssica Marcela de Luna [UNESP]
Santiago Júnior, Joel Ferreira
Lemos, Cleidiel Aparecido Araújo [UNESP]
Verri, Fellippo Ramos [UNESP]
dc.subject.por.fl_str_mv CAD/CAM
Dental soldering
Marginal adaptation
Misfit
Welding
topic CAD/CAM
Dental soldering
Marginal adaptation
Misfit
Welding
description The aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups.
publishDate 2018
dc.date.none.fl_str_mv 2018-07-01
2019-10-06T16:06:34Z
2019-10-06T16:06:34Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/0103-6440201801916
Brazilian Dental Journal, v. 29, n. 4, p. 342-346, 2018.
1806-4760
0103-6440
http://hdl.handle.net/11449/188393
10.1590/0103-6440201801916
S0103-64402018000400342
2-s2.0-85056982486
S0103-64402018000400342.pdf
url http://dx.doi.org/10.1590/0103-6440201801916
http://hdl.handle.net/11449/188393
identifier_str_mv Brazilian Dental Journal, v. 29, n. 4, p. 342-346, 2018.
1806-4760
0103-6440
10.1590/0103-6440201801916
S0103-64402018000400342
2-s2.0-85056982486
S0103-64402018000400342.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Dental Journal
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 342-346
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546399581601792