Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/0103-6440202003268 http://hdl.handle.net/11449/208167 |
Resumo: | The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; α=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings. |
id |
UNSP_32a09fea609cf5bd87114b51203b3d47 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/208167 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro studyDenture cleanserOverdentureRetentionScanning electronic microscopyThe aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; α=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Ribeirão Preto School of Dentistry USP-Universidade de São PauloAraraquara School of Dentistry UNESP-Universidade Estadual PaulistaAraraquara School of Dentistry UNESP-Universidade Estadual PaulistaFAPESP: 2011/20830-2Universidade de São Paulo (USP)Universidade Estadual Paulista (Unesp)Felipucci, Daniela Nair BorgesCurylofo, Patricia AlmeidaCrizóstomo, Luciana CostaVaz, Luis Geraldo [UNESP]Alves, Suleima Do ValeMacedo, Ana PaulaPagnano, Valéria Oliveira2021-06-25T11:07:34Z2021-06-25T11:07:34Z2020-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article657-663application/pdfhttp://dx.doi.org/10.1590/0103-6440202003268Brazilian Dental Journal, v. 31, n. 6, p. 657-663, 2020.1806-47600103-6440http://hdl.handle.net/11449/20816710.1590/0103-6440202003268S0103-644020200006006572-s2.0-85096432585S0103-64402020000600657.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journalinfo:eu-repo/semantics/openAccess2024-09-27T14:57:07Zoai:repositorio.unesp.br:11449/208167Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T14:57:07Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
title |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
spellingShingle |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study Felipucci, Daniela Nair Borges Denture cleanser Overdenture Retention Scanning electronic microscopy |
title_short |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
title_full |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
title_fullStr |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
title_full_unstemmed |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
title_sort |
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study |
author |
Felipucci, Daniela Nair Borges |
author_facet |
Felipucci, Daniela Nair Borges Curylofo, Patricia Almeida Crizóstomo, Luciana Costa Vaz, Luis Geraldo [UNESP] Alves, Suleima Do Vale Macedo, Ana Paula Pagnano, Valéria Oliveira |
author_role |
author |
author2 |
Curylofo, Patricia Almeida Crizóstomo, Luciana Costa Vaz, Luis Geraldo [UNESP] Alves, Suleima Do Vale Macedo, Ana Paula Pagnano, Valéria Oliveira |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade de São Paulo (USP) Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Felipucci, Daniela Nair Borges Curylofo, Patricia Almeida Crizóstomo, Luciana Costa Vaz, Luis Geraldo [UNESP] Alves, Suleima Do Vale Macedo, Ana Paula Pagnano, Valéria Oliveira |
dc.subject.por.fl_str_mv |
Denture cleanser Overdenture Retention Scanning electronic microscopy |
topic |
Denture cleanser Overdenture Retention Scanning electronic microscopy |
description |
The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; α=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-11-01 2021-06-25T11:07:34Z 2021-06-25T11:07:34Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/0103-6440202003268 Brazilian Dental Journal, v. 31, n. 6, p. 657-663, 2020. 1806-4760 0103-6440 http://hdl.handle.net/11449/208167 10.1590/0103-6440202003268 S0103-64402020000600657 2-s2.0-85096432585 S0103-64402020000600657.pdf |
url |
http://dx.doi.org/10.1590/0103-6440202003268 http://hdl.handle.net/11449/208167 |
identifier_str_mv |
Brazilian Dental Journal, v. 31, n. 6, p. 657-663, 2020. 1806-4760 0103-6440 10.1590/0103-6440202003268 S0103-64402020000600657 2-s2.0-85096432585 S0103-64402020000600657.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian Dental Journal |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
657-663 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546460317220864 |