Flow boiling pressure drop of R-1270 in 1.0 mm tube
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1016/j.applthermaleng.2023.120885 http://hdl.handle.net/11449/247563 |
Resumo: | This study experimentally investigated the flow boiling pressure drop and flow patterns of R-1270 in a horizontal circular tube with 1.0 mm ID. The experiments were carried out with mass flux between 240 and 480 kg/(m2s) and heat flux ranging from 5 to 60 kW/m2 at a saturation temperature of 25 °C. Flow patterns and void fraction distribution among channels were observed with a high-speed camera in a visualization section. The influence of mass flux and vapour quality on pressure drop was verified. The flow patterns identified during tests were plug, slug churn and wavy-annular, differently distributed along the channels. The results were also compared with eight different correlations proposed in the literature. Results indicate the dependence of pressure drop on both mass and vapour quality. |
id |
UNSP_33ed56aafacb9a684c1991b6f76f6e8f |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/247563 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Flow boiling pressure drop of R-1270 in 1.0 mm tubeFlow boilingFlow patternsMinichannelPressure dropPropyleneThis study experimentally investigated the flow boiling pressure drop and flow patterns of R-1270 in a horizontal circular tube with 1.0 mm ID. The experiments were carried out with mass flux between 240 and 480 kg/(m2s) and heat flux ranging from 5 to 60 kW/m2 at a saturation temperature of 25 °C. Flow patterns and void fraction distribution among channels were observed with a high-speed camera in a visualization section. The influence of mass flux and vapour quality on pressure drop was verified. The flow patterns identified during tests were plug, slug churn and wavy-annular, differently distributed along the channels. The results were also compared with eight different correlations proposed in the literature. Results indicate the dependence of pressure drop on both mass and vapour quality.FSG - University Center of Serra Gaúcha Center of Innovation and Technology Department of Mechanical Engineering, Os Dezoito do Forte St., 2366, RSMechanical Engineering Graduate Program LETEF Laboratory of Thermal and Fluid Dynamic Studies University of Vale do Rio dos Sinos, 93022-750 RSUNESP - São Paulo State University School of Engineering Post-Graduation Program in Mechanical Engineering, Av. Brasil, 56, SPUNESP - São Paulo State University School of Engineering, São João da Boa VistaMEtRICs Mechanical Engineering Department Campus de Azurém University of MinhoUNESP - São Paulo State University School of Engineering Post-Graduation Program in Mechanical Engineering, Av. Brasil, 56, SPUNESP - São Paulo State University School of Engineering, São João da Boa VistaCenter of Innovation and TechnologyUniversity of Vale do Rio dos SinosUniversidade Estadual Paulista (UNESP)University of MinhoDiehl de Oliveira, JefersonCopetti, Jacqueline BianconCardoso, Elaine Maria [UNESP]Rodrigues de Souza, Reinaldo2023-07-29T13:19:26Z2023-07-29T13:19:26Z2023-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1016/j.applthermaleng.2023.120885Applied Thermal Engineering, v. 231.1359-4311http://hdl.handle.net/11449/24756310.1016/j.applthermaleng.2023.1208852-s2.0-85161597438Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengApplied Thermal Engineeringinfo:eu-repo/semantics/openAccess2023-07-29T13:19:26Zoai:repositorio.unesp.br:11449/247563Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:20:59.663983Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
title |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
spellingShingle |
Flow boiling pressure drop of R-1270 in 1.0 mm tube Diehl de Oliveira, Jeferson Flow boiling Flow patterns Minichannel Pressure drop Propylene |
title_short |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
title_full |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
title_fullStr |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
title_full_unstemmed |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
title_sort |
Flow boiling pressure drop of R-1270 in 1.0 mm tube |
author |
Diehl de Oliveira, Jeferson |
author_facet |
Diehl de Oliveira, Jeferson Copetti, Jacqueline Biancon Cardoso, Elaine Maria [UNESP] Rodrigues de Souza, Reinaldo |
author_role |
author |
author2 |
Copetti, Jacqueline Biancon Cardoso, Elaine Maria [UNESP] Rodrigues de Souza, Reinaldo |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Center of Innovation and Technology University of Vale do Rio dos Sinos Universidade Estadual Paulista (UNESP) University of Minho |
dc.contributor.author.fl_str_mv |
Diehl de Oliveira, Jeferson Copetti, Jacqueline Biancon Cardoso, Elaine Maria [UNESP] Rodrigues de Souza, Reinaldo |
dc.subject.por.fl_str_mv |
Flow boiling Flow patterns Minichannel Pressure drop Propylene |
topic |
Flow boiling Flow patterns Minichannel Pressure drop Propylene |
description |
This study experimentally investigated the flow boiling pressure drop and flow patterns of R-1270 in a horizontal circular tube with 1.0 mm ID. The experiments were carried out with mass flux between 240 and 480 kg/(m2s) and heat flux ranging from 5 to 60 kW/m2 at a saturation temperature of 25 °C. Flow patterns and void fraction distribution among channels were observed with a high-speed camera in a visualization section. The influence of mass flux and vapour quality on pressure drop was verified. The flow patterns identified during tests were plug, slug churn and wavy-annular, differently distributed along the channels. The results were also compared with eight different correlations proposed in the literature. Results indicate the dependence of pressure drop on both mass and vapour quality. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-07-29T13:19:26Z 2023-07-29T13:19:26Z 2023-08-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.applthermaleng.2023.120885 Applied Thermal Engineering, v. 231. 1359-4311 http://hdl.handle.net/11449/247563 10.1016/j.applthermaleng.2023.120885 2-s2.0-85161597438 |
url |
http://dx.doi.org/10.1016/j.applthermaleng.2023.120885 http://hdl.handle.net/11449/247563 |
identifier_str_mv |
Applied Thermal Engineering, v. 231. 1359-4311 10.1016/j.applthermaleng.2023.120885 2-s2.0-85161597438 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Applied Thermal Engineering |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129191287193600 |