Flow boiling pressure drop of R-1270 in 1.0 mm tube

Detalhes bibliográficos
Autor(a) principal: Diehl de Oliveira, Jeferson
Data de Publicação: 2023
Outros Autores: Copetti, Jacqueline Biancon, Cardoso, Elaine Maria [UNESP], Rodrigues de Souza, Reinaldo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.applthermaleng.2023.120885
http://hdl.handle.net/11449/247563
Resumo: This study experimentally investigated the flow boiling pressure drop and flow patterns of R-1270 in a horizontal circular tube with 1.0 mm ID. The experiments were carried out with mass flux between 240 and 480 kg/(m2s) and heat flux ranging from 5 to 60 kW/m2 at a saturation temperature of 25 °C. Flow patterns and void fraction distribution among channels were observed with a high-speed camera in a visualization section. The influence of mass flux and vapour quality on pressure drop was verified. The flow patterns identified during tests were plug, slug churn and wavy-annular, differently distributed along the channels. The results were also compared with eight different correlations proposed in the literature. Results indicate the dependence of pressure drop on both mass and vapour quality.
id UNSP_33ed56aafacb9a684c1991b6f76f6e8f
oai_identifier_str oai:repositorio.unesp.br:11449/247563
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Flow boiling pressure drop of R-1270 in 1.0 mm tubeFlow boilingFlow patternsMinichannelPressure dropPropyleneThis study experimentally investigated the flow boiling pressure drop and flow patterns of R-1270 in a horizontal circular tube with 1.0 mm ID. The experiments were carried out with mass flux between 240 and 480 kg/(m2s) and heat flux ranging from 5 to 60 kW/m2 at a saturation temperature of 25 °C. Flow patterns and void fraction distribution among channels were observed with a high-speed camera in a visualization section. The influence of mass flux and vapour quality on pressure drop was verified. The flow patterns identified during tests were plug, slug churn and wavy-annular, differently distributed along the channels. The results were also compared with eight different correlations proposed in the literature. Results indicate the dependence of pressure drop on both mass and vapour quality.FSG - University Center of Serra Gaúcha Center of Innovation and Technology Department of Mechanical Engineering, Os Dezoito do Forte St., 2366, RSMechanical Engineering Graduate Program LETEF Laboratory of Thermal and Fluid Dynamic Studies University of Vale do Rio dos Sinos, 93022-750 RSUNESP - São Paulo State University School of Engineering Post-Graduation Program in Mechanical Engineering, Av. Brasil, 56, SPUNESP - São Paulo State University School of Engineering, São João da Boa VistaMEtRICs Mechanical Engineering Department Campus de Azurém University of MinhoUNESP - São Paulo State University School of Engineering Post-Graduation Program in Mechanical Engineering, Av. Brasil, 56, SPUNESP - São Paulo State University School of Engineering, São João da Boa VistaCenter of Innovation and TechnologyUniversity of Vale do Rio dos SinosUniversidade Estadual Paulista (UNESP)University of MinhoDiehl de Oliveira, JefersonCopetti, Jacqueline BianconCardoso, Elaine Maria [UNESP]Rodrigues de Souza, Reinaldo2023-07-29T13:19:26Z2023-07-29T13:19:26Z2023-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1016/j.applthermaleng.2023.120885Applied Thermal Engineering, v. 231.1359-4311http://hdl.handle.net/11449/24756310.1016/j.applthermaleng.2023.1208852-s2.0-85161597438Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengApplied Thermal Engineeringinfo:eu-repo/semantics/openAccess2023-07-29T13:19:26Zoai:repositorio.unesp.br:11449/247563Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:20:59.663983Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Flow boiling pressure drop of R-1270 in 1.0 mm tube
title Flow boiling pressure drop of R-1270 in 1.0 mm tube
spellingShingle Flow boiling pressure drop of R-1270 in 1.0 mm tube
Diehl de Oliveira, Jeferson
Flow boiling
Flow patterns
Minichannel
Pressure drop
Propylene
title_short Flow boiling pressure drop of R-1270 in 1.0 mm tube
title_full Flow boiling pressure drop of R-1270 in 1.0 mm tube
title_fullStr Flow boiling pressure drop of R-1270 in 1.0 mm tube
title_full_unstemmed Flow boiling pressure drop of R-1270 in 1.0 mm tube
title_sort Flow boiling pressure drop of R-1270 in 1.0 mm tube
author Diehl de Oliveira, Jeferson
author_facet Diehl de Oliveira, Jeferson
Copetti, Jacqueline Biancon
Cardoso, Elaine Maria [UNESP]
Rodrigues de Souza, Reinaldo
author_role author
author2 Copetti, Jacqueline Biancon
Cardoso, Elaine Maria [UNESP]
Rodrigues de Souza, Reinaldo
author2_role author
author
author
dc.contributor.none.fl_str_mv Center of Innovation and Technology
University of Vale do Rio dos Sinos
Universidade Estadual Paulista (UNESP)
University of Minho
dc.contributor.author.fl_str_mv Diehl de Oliveira, Jeferson
Copetti, Jacqueline Biancon
Cardoso, Elaine Maria [UNESP]
Rodrigues de Souza, Reinaldo
dc.subject.por.fl_str_mv Flow boiling
Flow patterns
Minichannel
Pressure drop
Propylene
topic Flow boiling
Flow patterns
Minichannel
Pressure drop
Propylene
description This study experimentally investigated the flow boiling pressure drop and flow patterns of R-1270 in a horizontal circular tube with 1.0 mm ID. The experiments were carried out with mass flux between 240 and 480 kg/(m2s) and heat flux ranging from 5 to 60 kW/m2 at a saturation temperature of 25 °C. Flow patterns and void fraction distribution among channels were observed with a high-speed camera in a visualization section. The influence of mass flux and vapour quality on pressure drop was verified. The flow patterns identified during tests were plug, slug churn and wavy-annular, differently distributed along the channels. The results were also compared with eight different correlations proposed in the literature. Results indicate the dependence of pressure drop on both mass and vapour quality.
publishDate 2023
dc.date.none.fl_str_mv 2023-07-29T13:19:26Z
2023-07-29T13:19:26Z
2023-08-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.applthermaleng.2023.120885
Applied Thermal Engineering, v. 231.
1359-4311
http://hdl.handle.net/11449/247563
10.1016/j.applthermaleng.2023.120885
2-s2.0-85161597438
url http://dx.doi.org/10.1016/j.applthermaleng.2023.120885
http://hdl.handle.net/11449/247563
identifier_str_mv Applied Thermal Engineering, v. 231.
1359-4311
10.1016/j.applthermaleng.2023.120885
2-s2.0-85161597438
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Applied Thermal Engineering
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129191287193600