Laboratory testes with quality data in Dentistry

Detalhes bibliográficos
Autor(a) principal: Campos, Juliana Alvares Duarte Bonini [UNESP]
Data de Publicação: 2013
Outros Autores: Oliveira, Ana Luísa Botta Martins de, Santos, Patrícia Aleixo do, Oliveira, Ana Carolina Botta Martins de, Garcia, Patrícia Petromilli Nordi Sasso [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.portaldeperiodicos.unisul.br/index.php/JR_Dentistry/article/view/1706
http://hdl.handle.net/11449/126013
Resumo: In laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.
id UNSP_36592bc3e55df43b56cde79a58404f97
oai_identifier_str oai:repositorio.unesp.br:11449/126013
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Laboratory testes with quality data in DentistryReproducibility of resultsLaboratory researchDentistryIn laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.Universidade Federal de Juiz de Fora, Departamento de Odontologia Social e InfantilCentro Universitário de Araraquara, Departamento de OdontologiaStony Brook University, Department of General DentistryUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Odontologia Social, Faculdade de Odontologia de AraraquaraUniversidade Estadual Paulista (Unesp)Universidade Federal de Juiz de Fora (UFJF)Centro Universitário de Araraquara (UNIARA)Stony Brook UniversityCampos, Juliana Alvares Duarte Bonini [UNESP]Oliveira, Ana Luísa Botta Martins deSantos, Patrícia Aleixo doOliveira, Ana Carolina Botta Martins deGarcia, Patrícia Petromilli Nordi Sasso [UNESP]2015-08-06T16:13:43Z2015-08-06T16:13:43Z2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article288-297application/pdfhttp://www.portaldeperiodicos.unisul.br/index.php/JR_Dentistry/article/view/1706Journal of Research in Dentistry, v. 1, n. 4, p. 288-297, 2013.2317-5907http://hdl.handle.net/11449/126013ISSN2317-5907-2013-01-04-288-297.pdf1307608053028698385621441789195907185197315506440000-0003-4607-5975Currículo Lattesreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Research in Dentistryinfo:eu-repo/semantics/openAccess2024-09-27T18:43:08Zoai:repositorio.unesp.br:11449/126013Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T18:43:08Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Laboratory testes with quality data in Dentistry
title Laboratory testes with quality data in Dentistry
spellingShingle Laboratory testes with quality data in Dentistry
Campos, Juliana Alvares Duarte Bonini [UNESP]
Reproducibility of results
Laboratory research
Dentistry
title_short Laboratory testes with quality data in Dentistry
title_full Laboratory testes with quality data in Dentistry
title_fullStr Laboratory testes with quality data in Dentistry
title_full_unstemmed Laboratory testes with quality data in Dentistry
title_sort Laboratory testes with quality data in Dentistry
author Campos, Juliana Alvares Duarte Bonini [UNESP]
author_facet Campos, Juliana Alvares Duarte Bonini [UNESP]
Oliveira, Ana Luísa Botta Martins de
Santos, Patrícia Aleixo do
Oliveira, Ana Carolina Botta Martins de
Garcia, Patrícia Petromilli Nordi Sasso [UNESP]
author_role author
author2 Oliveira, Ana Luísa Botta Martins de
Santos, Patrícia Aleixo do
Oliveira, Ana Carolina Botta Martins de
Garcia, Patrícia Petromilli Nordi Sasso [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade Federal de Juiz de Fora (UFJF)
Centro Universitário de Araraquara (UNIARA)
Stony Brook University
dc.contributor.author.fl_str_mv Campos, Juliana Alvares Duarte Bonini [UNESP]
Oliveira, Ana Luísa Botta Martins de
Santos, Patrícia Aleixo do
Oliveira, Ana Carolina Botta Martins de
Garcia, Patrícia Petromilli Nordi Sasso [UNESP]
dc.subject.por.fl_str_mv Reproducibility of results
Laboratory research
Dentistry
topic Reproducibility of results
Laboratory research
Dentistry
description In laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.
publishDate 2013
dc.date.none.fl_str_mv 2013
2015-08-06T16:13:43Z
2015-08-06T16:13:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.portaldeperiodicos.unisul.br/index.php/JR_Dentistry/article/view/1706
Journal of Research in Dentistry, v. 1, n. 4, p. 288-297, 2013.
2317-5907
http://hdl.handle.net/11449/126013
ISSN2317-5907-2013-01-04-288-297.pdf
1307608053028698
3856214417891959
0718519731550644
0000-0003-4607-5975
url http://www.portaldeperiodicos.unisul.br/index.php/JR_Dentistry/article/view/1706
http://hdl.handle.net/11449/126013
identifier_str_mv Journal of Research in Dentistry, v. 1, n. 4, p. 288-297, 2013.
2317-5907
ISSN2317-5907-2013-01-04-288-297.pdf
1307608053028698
3856214417891959
0718519731550644
0000-0003-4607-5975
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Research in Dentistry
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 288-297
application/pdf
dc.source.none.fl_str_mv Currículo Lattes
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546471885111296