A novel high frequency ac voltage regulator with active power factor correction
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1109/ISIE.2003.1267258 http://hdl.handle.net/11449/227052 |
Resumo: | This paper describes a novel high frequency ac voltage-regulator using a single ended primary inductance converter as power stage, and active power factor correction through the use of variable hysteresis control technique. The main advantage of this ac voltage-regulator concerns with the smaller volume, and size than the conventional ones. Nowadays, due to power quality standards, high input power factor is a necessity for power electronic converters, to perform that the input current total harmonic distortion (THB) fits into the limits of the standards, like IEC 61000-3-2 limits. It should be noticed that the input current THD for the novel ac high frequency voltage-regulator are in agreement with the requirements defined in the IEC 61000-3-2 standards. This paper presents a complete analysis, design and simulation results for a prototype rated at 300 W, operating with variable switching frequency (30 Hz until 90 kHz), and 127Vrms of nominal output voltages. |
id |
UNSP_40a093b4b7f8f17767774b715046a6bb |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/227052 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
A novel high frequency ac voltage regulator with active power factor correctionElectric variables controlFrequency conversionHysteresisIEC standardsInductancePower factor correctionPower qualityReactive powerRegulatorsVoltage controlThis paper describes a novel high frequency ac voltage-regulator using a single ended primary inductance converter as power stage, and active power factor correction through the use of variable hysteresis control technique. The main advantage of this ac voltage-regulator concerns with the smaller volume, and size than the conventional ones. Nowadays, due to power quality standards, high input power factor is a necessity for power electronic converters, to perform that the input current total harmonic distortion (THB) fits into the limits of the standards, like IEC 61000-3-2 limits. It should be noticed that the input current THD for the novel ac high frequency voltage-regulator are in agreement with the requirements defined in the IEC 61000-3-2 standards. This paper presents a complete analysis, design and simulation results for a prototype rated at 300 W, operating with variable switching frequency (30 Hz until 90 kHz), and 127Vrms of nominal output voltages.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)UNIDERP, P.O. Box 2153DEE, FEIS-UNESP, Paulista State University, P.O. Box 3 1DEE, FEIS-UNESP, Paulista State University, P.O. Box 3 1UNIDERPUniversidade Estadual Paulista (UNESP)Dantas, F. D.Canesin, C. A. [UNESP]2022-04-29T06:01:27Z2022-04-29T06:01:27Z2003-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject275-279http://dx.doi.org/10.1109/ISIE.2003.1267258IEEE International Symposium on Industrial Electronics, v. I, p. 275-279.http://hdl.handle.net/11449/22705210.1109/ISIE.2003.12672582-s2.0-84870555791Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengIEEE International Symposium on Industrial Electronicsinfo:eu-repo/semantics/openAccess2024-07-04T19:11:44Zoai:repositorio.unesp.br:11449/227052Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:49:29.138059Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
A novel high frequency ac voltage regulator with active power factor correction |
title |
A novel high frequency ac voltage regulator with active power factor correction |
spellingShingle |
A novel high frequency ac voltage regulator with active power factor correction Dantas, F. D. Electric variables control Frequency conversion Hysteresis IEC standards Inductance Power factor correction Power quality Reactive power Regulators Voltage control |
title_short |
A novel high frequency ac voltage regulator with active power factor correction |
title_full |
A novel high frequency ac voltage regulator with active power factor correction |
title_fullStr |
A novel high frequency ac voltage regulator with active power factor correction |
title_full_unstemmed |
A novel high frequency ac voltage regulator with active power factor correction |
title_sort |
A novel high frequency ac voltage regulator with active power factor correction |
author |
Dantas, F. D. |
author_facet |
Dantas, F. D. Canesin, C. A. [UNESP] |
author_role |
author |
author2 |
Canesin, C. A. [UNESP] |
author2_role |
author |
dc.contributor.none.fl_str_mv |
UNIDERP Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Dantas, F. D. Canesin, C. A. [UNESP] |
dc.subject.por.fl_str_mv |
Electric variables control Frequency conversion Hysteresis IEC standards Inductance Power factor correction Power quality Reactive power Regulators Voltage control |
topic |
Electric variables control Frequency conversion Hysteresis IEC standards Inductance Power factor correction Power quality Reactive power Regulators Voltage control |
description |
This paper describes a novel high frequency ac voltage-regulator using a single ended primary inductance converter as power stage, and active power factor correction through the use of variable hysteresis control technique. The main advantage of this ac voltage-regulator concerns with the smaller volume, and size than the conventional ones. Nowadays, due to power quality standards, high input power factor is a necessity for power electronic converters, to perform that the input current total harmonic distortion (THB) fits into the limits of the standards, like IEC 61000-3-2 limits. It should be noticed that the input current THD for the novel ac high frequency voltage-regulator are in agreement with the requirements defined in the IEC 61000-3-2 standards. This paper presents a complete analysis, design and simulation results for a prototype rated at 300 W, operating with variable switching frequency (30 Hz until 90 kHz), and 127Vrms of nominal output voltages. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-01-01 2022-04-29T06:01:27Z 2022-04-29T06:01:27Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1109/ISIE.2003.1267258 IEEE International Symposium on Industrial Electronics, v. I, p. 275-279. http://hdl.handle.net/11449/227052 10.1109/ISIE.2003.1267258 2-s2.0-84870555791 |
url |
http://dx.doi.org/10.1109/ISIE.2003.1267258 http://hdl.handle.net/11449/227052 |
identifier_str_mv |
IEEE International Symposium on Industrial Electronics, v. I, p. 275-279. 10.1109/ISIE.2003.1267258 2-s2.0-84870555791 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
IEEE International Symposium on Industrial Electronics |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
275-279 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129124457250816 |