Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times

Detalhes bibliográficos
Autor(a) principal: Di Nicoló, Rebeca [UNESP]
Data de Publicação: 2010
Outros Autores: de Araujo, Maria Amelia Maximo [UNESP], Alves, Levy Anderson César [UNESP], de Assunçao e Souza, Rodrigo Othavio [UNESP], da Rocha, Daniel Maranha [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S1806-83242010000100011
http://hdl.handle.net/11449/71534
Resumo: The aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the photoactivation system used (QTH or LED). The enamel surfaces were conditioned with Transbond self-etching primer, and APC (Adhesive Pre-Coated) brackets were used in all specimens. Group I was cured with QTH for 20 s and Group II with LED for 10 s. Both groups were subdivided according to the different experimental times after bonding (immediately, 24 h and 7 days). The specimens were tested for SBS and the enamel surfaces were analyzed according to the Adhesive Remnant Index (ARI). The statistical analysis included the Tukey's test to evaluate the main effects of photoactivation and debond time on SBS. The Chi-square test was used to compare the ARI values found for each group, and no statistically significant difference was observed. The debond time of 7 days for QTH photoactivation showed statistically greater values of SBS when compared to the immediate and 24 h periods. There was no statistically significant difference between the QTH and LED groups immediately and after the 24 h period. In conclusion, bonding orthodontic brackets with LED photoactivation for 10 s is suggested because it requires a reduced clinical chair time.
id UNSP_42837f0d0f9391225d1931447f80a0be
oai_identifier_str oai:repositorio.unesp.br:11449/71534
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond timesCuring lightsDentalDental debondingDental etchingOrthodontic bracketsresin cementanimalcattledental acid etchingdental bondingdental debondingdental equipmentmaterials testingmethodologyorthodontic deviceradiation exposureshear strengthsurface propertytimeAcid Etching, DentalAnimalsCattleCuring Lights, DentalDental DebondingLight-Curing of Dental AdhesivesMaterials TestingOrthodontic BracketsResin CementsShear StrengthSurface PropertiesTime FactorsThe aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the photoactivation system used (QTH or LED). The enamel surfaces were conditioned with Transbond self-etching primer, and APC (Adhesive Pre-Coated) brackets were used in all specimens. Group I was cured with QTH for 20 s and Group II with LED for 10 s. Both groups were subdivided according to the different experimental times after bonding (immediately, 24 h and 7 days). The specimens were tested for SBS and the enamel surfaces were analyzed according to the Adhesive Remnant Index (ARI). The statistical analysis included the Tukey's test to evaluate the main effects of photoactivation and debond time on SBS. The Chi-square test was used to compare the ARI values found for each group, and no statistically significant difference was observed. The debond time of 7 days for QTH photoactivation showed statistically greater values of SBS when compared to the immediate and 24 h periods. There was no statistically significant difference between the QTH and LED groups immediately and after the 24 h period. In conclusion, bonding orthodontic brackets with LED photoactivation for 10 s is suggested because it requires a reduced clinical chair time.Department of Orthodontics and Pediatric Dentistry Faculdade de Odontologia de São José dos Campos Unesp, Univ Estadual Paulista, São José dos Campos, SPDepartment of Restorative Dentistry Faculdade de Odontologia de São José dos Campos Unesp - Univ Estadual Paulista, São José dos Campos, SPDepartment of Prosthesis Faculdade de Odontologia de São José dos Campos Unesp - Univ Estadual Paulista, São José dos Campos, SPDepartment of Orthodontics and Pediatric Dentistry Faculdade de Odontologia de São José dos Campos Unesp, Univ Estadual Paulista, São José dos Campos, SPDepartment of Restorative Dentistry Faculdade de Odontologia de São José dos Campos Unesp - Univ Estadual Paulista, São José dos Campos, SPDepartment of Prosthesis Faculdade de Odontologia de São José dos Campos Unesp - Univ Estadual Paulista, São José dos Campos, SPUniversidade Estadual Paulista (Unesp)Di Nicoló, Rebeca [UNESP]de Araujo, Maria Amelia Maximo [UNESP]Alves, Levy Anderson César [UNESP]de Assunçao e Souza, Rodrigo Othavio [UNESP]da Rocha, Daniel Maranha [UNESP]2014-05-27T11:24:36Z2014-05-27T11:24:36Z2010-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article64-69application/pdfhttp://dx.doi.org/10.1590/S1806-83242010000100011Brazilian Oral Research, v. 24, n. 1, p. 64-69, 2010.1806-83241807-3107http://hdl.handle.net/11449/7153410.1590/S1806-83242010000100011S1806-832420100001000112-s2.0-779555230742-s2.0-77955523074.pdf925532246124152741537381829372490000-0001-9132-0429Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Oral Research1.223info:eu-repo/semantics/openAccess2023-10-24T06:06:00Zoai:repositorio.unesp.br:11449/71534Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:48:40.549659Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
title Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
spellingShingle Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
Di Nicoló, Rebeca [UNESP]
Curing lights
Dental
Dental debonding
Dental etching
Orthodontic brackets
resin cement
animal
cattle
dental acid etching
dental bonding
dental debonding
dental equipment
materials testing
methodology
orthodontic device
radiation exposure
shear strength
surface property
time
Acid Etching, Dental
Animals
Cattle
Curing Lights, Dental
Dental Debonding
Light-Curing of Dental Adhesives
Materials Testing
Orthodontic Brackets
Resin Cements
Shear Strength
Surface Properties
Time Factors
title_short Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
title_full Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
title_fullStr Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
title_full_unstemmed Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
title_sort Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times
author Di Nicoló, Rebeca [UNESP]
author_facet Di Nicoló, Rebeca [UNESP]
de Araujo, Maria Amelia Maximo [UNESP]
Alves, Levy Anderson César [UNESP]
de Assunçao e Souza, Rodrigo Othavio [UNESP]
da Rocha, Daniel Maranha [UNESP]
author_role author
author2 de Araujo, Maria Amelia Maximo [UNESP]
Alves, Levy Anderson César [UNESP]
de Assunçao e Souza, Rodrigo Othavio [UNESP]
da Rocha, Daniel Maranha [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Di Nicoló, Rebeca [UNESP]
de Araujo, Maria Amelia Maximo [UNESP]
Alves, Levy Anderson César [UNESP]
de Assunçao e Souza, Rodrigo Othavio [UNESP]
da Rocha, Daniel Maranha [UNESP]
dc.subject.por.fl_str_mv Curing lights
Dental
Dental debonding
Dental etching
Orthodontic brackets
resin cement
animal
cattle
dental acid etching
dental bonding
dental debonding
dental equipment
materials testing
methodology
orthodontic device
radiation exposure
shear strength
surface property
time
Acid Etching, Dental
Animals
Cattle
Curing Lights, Dental
Dental Debonding
Light-Curing of Dental Adhesives
Materials Testing
Orthodontic Brackets
Resin Cements
Shear Strength
Surface Properties
Time Factors
topic Curing lights
Dental
Dental debonding
Dental etching
Orthodontic brackets
resin cement
animal
cattle
dental acid etching
dental bonding
dental debonding
dental equipment
materials testing
methodology
orthodontic device
radiation exposure
shear strength
surface property
time
Acid Etching, Dental
Animals
Cattle
Curing Lights, Dental
Dental Debonding
Light-Curing of Dental Adhesives
Materials Testing
Orthodontic Brackets
Resin Cements
Shear Strength
Surface Properties
Time Factors
description The aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the photoactivation system used (QTH or LED). The enamel surfaces were conditioned with Transbond self-etching primer, and APC (Adhesive Pre-Coated) brackets were used in all specimens. Group I was cured with QTH for 20 s and Group II with LED for 10 s. Both groups were subdivided according to the different experimental times after bonding (immediately, 24 h and 7 days). The specimens were tested for SBS and the enamel surfaces were analyzed according to the Adhesive Remnant Index (ARI). The statistical analysis included the Tukey's test to evaluate the main effects of photoactivation and debond time on SBS. The Chi-square test was used to compare the ARI values found for each group, and no statistically significant difference was observed. The debond time of 7 days for QTH photoactivation showed statistically greater values of SBS when compared to the immediate and 24 h periods. There was no statistically significant difference between the QTH and LED groups immediately and after the 24 h period. In conclusion, bonding orthodontic brackets with LED photoactivation for 10 s is suggested because it requires a reduced clinical chair time.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
2014-05-27T11:24:36Z
2014-05-27T11:24:36Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1806-83242010000100011
Brazilian Oral Research, v. 24, n. 1, p. 64-69, 2010.
1806-8324
1807-3107
http://hdl.handle.net/11449/71534
10.1590/S1806-83242010000100011
S1806-83242010000100011
2-s2.0-77955523074
2-s2.0-77955523074.pdf
9255322461241527
4153738182937249
0000-0001-9132-0429
url http://dx.doi.org/10.1590/S1806-83242010000100011
http://hdl.handle.net/11449/71534
identifier_str_mv Brazilian Oral Research, v. 24, n. 1, p. 64-69, 2010.
1806-8324
1807-3107
10.1590/S1806-83242010000100011
S1806-83242010000100011
2-s2.0-77955523074
2-s2.0-77955523074.pdf
9255322461241527
4153738182937249
0000-0001-9132-0429
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Oral Research
1.223
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 64-69
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128565271592960