Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares

Detalhes bibliográficos
Autor(a) principal: Carvalho, Helen Ramon Esper de [UNESP]
Data de Publicação: 2015
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/134207
http://www.athena.biblioteca.unesp.br/exlibris/bd/cathedra/28-01-2016/000857959.pdf
Resumo: Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative...
id UNSP_428421fda32e114194b3f66f009f6a20
oai_identifier_str oai:repositorio.unesp.br:11449/134207
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantaresImplantes dentáriosTransplante ósseoMateriais biomédicosDental implantsIntroduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative...Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere...Universidade Estadual Paulista (Unesp)Magro Filho, Osvaldo [UNESP]Universidade Estadual Paulista (Unesp)Carvalho, Helen Ramon Esper de [UNESP]2016-02-05T18:30:11Z2016-02-05T18:30:11Z2015-09-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis68 f : il. + 1 CD-ROMapplication/pdfCARVALHO, Helen Ramon Esper de. Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares. 2015. 68 f. Tese (doutorado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araçatuba, 2015.http://hdl.handle.net/11449/134207000857959http://www.athena.biblioteca.unesp.br/exlibris/bd/cathedra/28-01-2016/000857959.pdf33004021011P05535418670745125Alephreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporinfo:eu-repo/semantics/openAccess2023-11-30T06:18:02Zoai:repositorio.unesp.br:11449/134207Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:09:40.448796Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
title Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
spellingShingle Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
Carvalho, Helen Ramon Esper de [UNESP]
Implantes dentários
Transplante ósseo
Materiais biomédicos
Dental implants
title_short Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
title_full Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
title_fullStr Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
title_full_unstemmed Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
title_sort Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares
author Carvalho, Helen Ramon Esper de [UNESP]
author_facet Carvalho, Helen Ramon Esper de [UNESP]
author_role author
dc.contributor.none.fl_str_mv Magro Filho, Osvaldo [UNESP]
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Carvalho, Helen Ramon Esper de [UNESP]
dc.subject.por.fl_str_mv Implantes dentários
Transplante ósseo
Materiais biomédicos
Dental implants
topic Implantes dentários
Transplante ósseo
Materiais biomédicos
Dental implants
description Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative...
publishDate 2015
dc.date.none.fl_str_mv 2015-09-04
2016-02-05T18:30:11Z
2016-02-05T18:30:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv CARVALHO, Helen Ramon Esper de. Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares. 2015. 68 f. Tese (doutorado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araçatuba, 2015.
http://hdl.handle.net/11449/134207
000857959
http://www.athena.biblioteca.unesp.br/exlibris/bd/cathedra/28-01-2016/000857959.pdf
33004021011P0
5535418670745125
identifier_str_mv CARVALHO, Helen Ramon Esper de. Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares. 2015. 68 f. Tese (doutorado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araçatuba, 2015.
000857959
33004021011P0
5535418670745125
url http://hdl.handle.net/11449/134207
http://www.athena.biblioteca.unesp.br/exlibris/bd/cathedra/28-01-2016/000857959.pdf
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 68 f : il. + 1 CD-ROM
application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual Paulista (Unesp)
publisher.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.source.none.fl_str_mv Aleph
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129028051173376