Wettability behavior of nanotubular TiO2 intended for biomedical applications
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://www.archhealthinvestigation.com.br/index.php/ArcHI/article/view/658 http://hdl.handle.net/11449/133326 |
Resumo: | Nanotubes have been subject of studies with regard to their ability to promote differentiation of several cells lines. Nanotubes have been used to increase the roughness of the implant surfaces and to improve bone tissue integration on dental implant. In this study TiO2 nanotube layer prepared by anodic oxidation was evaluated. Nanotube formation was carried out using Glycerol-H2O DI(50-50 v/v)+NH4F(0,5 a 1,5% and 10-30V) for 1-3 hours at 37ºC. After nanostructure formation the topography of surface was observed using field-emission-scanning-microscope (FE-SEM). Contact angle was evaluated on the anodized and non-anodized surfaces using a water contact angle goniometer in sessile drop mode with 5 μL drops. In the case of nanotube formation and no treatment surface were presented 39,1° and 75,9°, respectively. The contact angle describing the wettability of the surface is enhanced, more hydrophilic, on the nanotube surfaces, which can be advantageous for enhancing protein adsorption and cell adhesion. |
id |
UNSP_43c06e8d2833037f95f08ff38e7d6b6a |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/133326 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Wettability behavior of nanotubular TiO2 intended for biomedical applicationsLa humectabilidad de nanotubos de TiO2 para aplicaciones biomédicasMolhabilidade de nanotubos de TiO2 para aplicações biomédicasTitaniumNanotubesWettabilityTitanioNanotubosHumectabilidadTitânioNanotubosMolhabilidadeNanotubes have been subject of studies with regard to their ability to promote differentiation of several cells lines. Nanotubes have been used to increase the roughness of the implant surfaces and to improve bone tissue integration on dental implant. In this study TiO2 nanotube layer prepared by anodic oxidation was evaluated. Nanotube formation was carried out using Glycerol-H2O DI(50-50 v/v)+NH4F(0,5 a 1,5% and 10-30V) for 1-3 hours at 37ºC. After nanostructure formation the topography of surface was observed using field-emission-scanning-microscope (FE-SEM). Contact angle was evaluated on the anodized and non-anodized surfaces using a water contact angle goniometer in sessile drop mode with 5 μL drops. In the case of nanotube formation and no treatment surface were presented 39,1° and 75,9°, respectively. The contact angle describing the wettability of the surface is enhanced, more hydrophilic, on the nanotube surfaces, which can be advantageous for enhancing protein adsorption and cell adhesion.Los nanotubos se han estudiado con respecto a su capacidad para promover la diferenciación de diversos linajes de células. Los nanotubos se han utilizado para aumentar la rugosidad de la superficie de los implantes y mejorar la integración del tejido óseo. En este estudio, TiO2 nanotubos se preparó por oxidación anódica. Los nanotubos fueron formados utilizando glicerol-DI H2O (50/50 v / v) + NH4F (0,5 a 1,5%, y 10-30) durante 1-3 horas a 37 ° C. La topografía de la superficie se evaluó en cuanto a la cantidad, el diámetro y la altura de los nanotubos cultivadas por microscopio electrónico de barrido (SEM) de alta resolución (FEG-SEM). La humectabilidad se evaluó midiendo el ángulo de contacto obtenido en la superficie usando goniómetro 300-F1 (Ramé-Hard Inst.Co) en el modo de la gota sésil con 5 gotas / microlitro. Los resultados mostraron valores medios de 39,1 ° a la superficie cubierta por nanotubos y 75,9 ° en la superficie no anodizado (control). El ángulo de contacto que describe la capacidad de amortiguación de la superficie se incrementó en las superficies de los nanotubos. La mayor hidrofilicidad puede resultar más ventajoso para mejorar la adsorción de proteínas y la adhesión celular.Nanotubos têm sido objeto de estudos no que se refere à sua capacidade de promover a diferenciação de várias linhagens celulares. Nanotubos têm sido utilizados para aumentar a rugosidade da superfície dos implantes e melhorar a integração do tecido ósseo. Neste estudo foi avaliada camada de TiO2 de nanotubos preparada por oxidação anódica. Nanotubos foram formados utilizando glicerol-H2O DI (50-50 v / v) + NH 4 F (0,5 a 1,5% e 10- 30) durante 1-3 horas a 37ºC. A topografia da superfície foi avaliada quanto à quantidade, diâmetro e altura dos nanotubos crescidos por meio de Microscópio Eletrônico de Varredura (MEV) de alta resolução (FEG-SEM). A molhabilidade foi avaliada por meio da mensuração do ângulo de contato obtido na superfície utilizando-se Goniômetro 300-F1 (Ramé-Hard Inst.Co) no modo de gota séssil com 5 gotas/microlitro. Resultados apontaram valores médios de 39,1 ° para superfície recoberta por nanotubos e 75,9° para superfície não-anodizada (controle). O ângulo de contato que descreve a capacidade de umedecimento da superfície mostrou-se aumentado sobre as superfícies de nanotubos. A maior hidrofilicidade pode se mostrar mais vantajosa para melhorar a adsorção de proteínas e adesão celular.Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araçatuba, Aracatuba, Rua José Bonifácio, 1193, Vila Mendonça, CEP 16015-050, SP, BrasilUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais e Tecnologia, Faculdade de Engenharia, Ilha Solteira, SP, BrasilUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araçatuba, Aracatuba, Rua José Bonifácio, 1193, Vila Mendonça, CEP 16015-050, SP, BrasilUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais e Tecnologia, Faculdade de Engenharia, Ilha Solteira, SP, BrasilUniversidade Estadual Paulista (Unesp)Rosa, Jorge LuizNakazato, Roberto Zenhei [UNESP]Schneider, Sandra GiacominAlves Claro, Ana Paula Rosifini [UNESP]Alves Rezende, Maria Cristina Rosifini [UNESP]2016-01-28T16:54:37Z2016-01-28T16:54:37Z2014info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article43-47application/pdfhttp://www.archhealthinvestigation.com.br/index.php/ArcHI/article/view/658Archives of Health Investigation, v. 3, n. 5, p. 43-47, 2014.2317-3009http://hdl.handle.net/11449/133326ISSN2317-3009-2014-03-05-43-47.pdf918448913452409787991910784514670000-0002-1327-96670000-0001-7897-1905Currículo Lattesreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengArchives of Health Investigationinfo:eu-repo/semantics/openAccess2024-09-19T14:50:35Zoai:repositorio.unesp.br:11449/133326Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-19T14:50:35Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Wettability behavior of nanotubular TiO2 intended for biomedical applications La humectabilidad de nanotubos de TiO2 para aplicaciones biomédicas Molhabilidade de nanotubos de TiO2 para aplicações biomédicas |
title |
Wettability behavior of nanotubular TiO2 intended for biomedical applications |
spellingShingle |
Wettability behavior of nanotubular TiO2 intended for biomedical applications Rosa, Jorge Luiz Titanium Nanotubes Wettability Titanio Nanotubos Humectabilidad Titânio Nanotubos Molhabilidade |
title_short |
Wettability behavior of nanotubular TiO2 intended for biomedical applications |
title_full |
Wettability behavior of nanotubular TiO2 intended for biomedical applications |
title_fullStr |
Wettability behavior of nanotubular TiO2 intended for biomedical applications |
title_full_unstemmed |
Wettability behavior of nanotubular TiO2 intended for biomedical applications |
title_sort |
Wettability behavior of nanotubular TiO2 intended for biomedical applications |
author |
Rosa, Jorge Luiz |
author_facet |
Rosa, Jorge Luiz Nakazato, Roberto Zenhei [UNESP] Schneider, Sandra Giacomin Alves Claro, Ana Paula Rosifini [UNESP] Alves Rezende, Maria Cristina Rosifini [UNESP] |
author_role |
author |
author2 |
Nakazato, Roberto Zenhei [UNESP] Schneider, Sandra Giacomin Alves Claro, Ana Paula Rosifini [UNESP] Alves Rezende, Maria Cristina Rosifini [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Rosa, Jorge Luiz Nakazato, Roberto Zenhei [UNESP] Schneider, Sandra Giacomin Alves Claro, Ana Paula Rosifini [UNESP] Alves Rezende, Maria Cristina Rosifini [UNESP] |
dc.subject.por.fl_str_mv |
Titanium Nanotubes Wettability Titanio Nanotubos Humectabilidad Titânio Nanotubos Molhabilidade |
topic |
Titanium Nanotubes Wettability Titanio Nanotubos Humectabilidad Titânio Nanotubos Molhabilidade |
description |
Nanotubes have been subject of studies with regard to their ability to promote differentiation of several cells lines. Nanotubes have been used to increase the roughness of the implant surfaces and to improve bone tissue integration on dental implant. In this study TiO2 nanotube layer prepared by anodic oxidation was evaluated. Nanotube formation was carried out using Glycerol-H2O DI(50-50 v/v)+NH4F(0,5 a 1,5% and 10-30V) for 1-3 hours at 37ºC. After nanostructure formation the topography of surface was observed using field-emission-scanning-microscope (FE-SEM). Contact angle was evaluated on the anodized and non-anodized surfaces using a water contact angle goniometer in sessile drop mode with 5 μL drops. In the case of nanotube formation and no treatment surface were presented 39,1° and 75,9°, respectively. The contact angle describing the wettability of the surface is enhanced, more hydrophilic, on the nanotube surfaces, which can be advantageous for enhancing protein adsorption and cell adhesion. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014 2016-01-28T16:54:37Z 2016-01-28T16:54:37Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.archhealthinvestigation.com.br/index.php/ArcHI/article/view/658 Archives of Health Investigation, v. 3, n. 5, p. 43-47, 2014. 2317-3009 http://hdl.handle.net/11449/133326 ISSN2317-3009-2014-03-05-43-47.pdf 9184489134524097 8799191078451467 0000-0002-1327-9667 0000-0001-7897-1905 |
url |
http://www.archhealthinvestigation.com.br/index.php/ArcHI/article/view/658 http://hdl.handle.net/11449/133326 |
identifier_str_mv |
Archives of Health Investigation, v. 3, n. 5, p. 43-47, 2014. 2317-3009 ISSN2317-3009-2014-03-05-43-47.pdf 9184489134524097 8799191078451467 0000-0002-1327-9667 0000-0001-7897-1905 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Archives of Health Investigation |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
43-47 application/pdf |
dc.source.none.fl_str_mv |
Currículo Lattes reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546390144417792 |