An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode

Detalhes bibliográficos
Autor(a) principal: Teixeira, Marcos F. S. [UNESP]
Data de Publicação: 2009
Outros Autores: Dadamos, Tony R. L. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.proche.2009.07.074
http://hdl.handle.net/11449/6972
Resumo: An amperometric dipyrone sensor based on a polymeric nickel-salen (salen = N,N'-ethylenebis(salicydeneiminato)) film coated platinum electrode was developed. The sensor was constructed by electropolymerization of nickel-salen complex at a platinum electrode in acetonitrile/tetrabuthylamonium perchlorate by cyclic voltammetry. After cycling the modified electrode in a 0.50 mol L-1 KCl solution, the estimated surface concentration was found to be equal to 1.29 x 10(-9) mol cm(-2). This is a typical behavior of an electrode surface immobilized with a redox couple that can usually be considered as a reversible single-electron reduction/oxidation of the nickel(II)/nickel(III) couple. A plot of the anodic current versus the dipyrone concentration for chronoamperometry (potential fixed = +0.50 V) at the sensor was linear in the 4.7 x 10(-6) to 1.1 x 10(-4) mol L-1 concentration range and the concentration limit was 1.2 x 10(-6) mol L-1. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations.
id UNSP_44219f2dd2cfb5c72184fc8606248fe9
oai_identifier_str oai:repositorio.unesp.br:11449/6972
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrodemodified electrodenickel-salen polymeramperometric detectiondipyrone analysisAn amperometric dipyrone sensor based on a polymeric nickel-salen (salen = N,N'-ethylenebis(salicydeneiminato)) film coated platinum electrode was developed. The sensor was constructed by electropolymerization of nickel-salen complex at a platinum electrode in acetonitrile/tetrabuthylamonium perchlorate by cyclic voltammetry. After cycling the modified electrode in a 0.50 mol L-1 KCl solution, the estimated surface concentration was found to be equal to 1.29 x 10(-9) mol cm(-2). This is a typical behavior of an electrode surface immobilized with a redox couple that can usually be considered as a reversible single-electron reduction/oxidation of the nickel(II)/nickel(III) couple. A plot of the anodic current versus the dipyrone concentration for chronoamperometry (potential fixed = +0.50 V) at the sensor was linear in the 4.7 x 10(-6) to 1.1 x 10(-4) mol L-1 concentration range and the concentration limit was 1.2 x 10(-6) mol L-1. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations.Univ State São Paulo UNESP, Dept Phys Chem & Biol, Fac Sci & Technol, Presidente Prudente, SP, BrazilUniv State São Paulo UNESP, Dept Phys Chem & Biol, Fac Sci & Technol, Presidente Prudente, SP, BrazilElsevier B.V.Universidade Estadual Paulista (Unesp)Teixeira, Marcos F. S. [UNESP]Dadamos, Tony R. L. [UNESP]2014-05-20T13:23:13Z2014-05-20T13:23:13Z2009-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article297-300application/pdfhttp://dx.doi.org/10.1016/j.proche.2009.07.074Proceedings of The Eurosensors Xxiii Conference. Amsterdam: Elsevier B.V., v. 1, n. 1, p. 297-300, 2009.1876-6196http://hdl.handle.net/11449/697210.1016/j.proche.2009.07.074WOS:000275995600210WOS000275995600210.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengProceedings of The Eurosensors Xxiii Conferenceinfo:eu-repo/semantics/openAccess2024-06-18T18:18:15Zoai:repositorio.unesp.br:11449/6972Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:30:23.790862Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
title An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
spellingShingle An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
Teixeira, Marcos F. S. [UNESP]
modified electrode
nickel-salen polymer
amperometric detection
dipyrone analysis
title_short An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
title_full An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
title_fullStr An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
title_full_unstemmed An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
title_sort An electrochemical sensor for dipyrone determination based on nickel-salen film modified electrode
author Teixeira, Marcos F. S. [UNESP]
author_facet Teixeira, Marcos F. S. [UNESP]
Dadamos, Tony R. L. [UNESP]
author_role author
author2 Dadamos, Tony R. L. [UNESP]
author2_role author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Teixeira, Marcos F. S. [UNESP]
Dadamos, Tony R. L. [UNESP]
dc.subject.por.fl_str_mv modified electrode
nickel-salen polymer
amperometric detection
dipyrone analysis
topic modified electrode
nickel-salen polymer
amperometric detection
dipyrone analysis
description An amperometric dipyrone sensor based on a polymeric nickel-salen (salen = N,N'-ethylenebis(salicydeneiminato)) film coated platinum electrode was developed. The sensor was constructed by electropolymerization of nickel-salen complex at a platinum electrode in acetonitrile/tetrabuthylamonium perchlorate by cyclic voltammetry. After cycling the modified electrode in a 0.50 mol L-1 KCl solution, the estimated surface concentration was found to be equal to 1.29 x 10(-9) mol cm(-2). This is a typical behavior of an electrode surface immobilized with a redox couple that can usually be considered as a reversible single-electron reduction/oxidation of the nickel(II)/nickel(III) couple. A plot of the anodic current versus the dipyrone concentration for chronoamperometry (potential fixed = +0.50 V) at the sensor was linear in the 4.7 x 10(-6) to 1.1 x 10(-4) mol L-1 concentration range and the concentration limit was 1.2 x 10(-6) mol L-1. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations.
publishDate 2009
dc.date.none.fl_str_mv 2009-01-01
2014-05-20T13:23:13Z
2014-05-20T13:23:13Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.proche.2009.07.074
Proceedings of The Eurosensors Xxiii Conference. Amsterdam: Elsevier B.V., v. 1, n. 1, p. 297-300, 2009.
1876-6196
http://hdl.handle.net/11449/6972
10.1016/j.proche.2009.07.074
WOS:000275995600210
WOS000275995600210.pdf
url http://dx.doi.org/10.1016/j.proche.2009.07.074
http://hdl.handle.net/11449/6972
identifier_str_mv Proceedings of The Eurosensors Xxiii Conference. Amsterdam: Elsevier B.V., v. 1, n. 1, p. 297-300, 2009.
1876-6196
10.1016/j.proche.2009.07.074
WOS:000275995600210
WOS000275995600210.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Proceedings of The Eurosensors Xxiii Conference
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 297-300
application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129211246837760