The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus

Detalhes bibliográficos
Autor(a) principal: Hoshino, K. [UNESP]
Data de Publicação: 2004
Outros Autores: Uga, D.A. [UNESP], de Paula, H.M.G. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S0100-879X2004000200012
http://hdl.handle.net/11449/28074
Resumo: Head dipping (HD) is a behavioral pattern considered to have a risk assessment or an exploratory role and is used as a complementary parameter to evaluate anxiety in experimental animals. Since rats with electrolytic lesion in the area of the median raphe nucleus displayed high frequencies of HD in a previous study, the present investigation was undertaken to confirm this observation and to determine its anxiety-related origin. HD episodes were counted in adult male Wistar rats (270-350 g) with electrolytic lesion (N = 11) and sham-lesioned controls (N = 12). When HD was measured for 60 min on an elevated open platform, lesioned rats emitted 13 times more HD than controls (264.7 ± 93.3 vs 20.3 ± 7.6 episodes), with the difference being statistically significant (P < 0.05). HD counts during 10-min sessions held 7, 14, 21, 27, and 63 days after lesion showed significantly higher means (range: 28.14 ± 5.38 to 62.85 ± 9.48) compared to sham-lesioned controls (range: 7.37 ± 1.13 to 8.5 ± 1.45). Normal rats stepped down into their home cages when the vertical distance between them and the cage was short (16 cm), and the step-down latencies increased with increasing depths (36.7 ± 7.92 to 185.87 ± 35.44 s). Lesioned rats showed a similar behavior when facing the shortest depth, but had a significantly increased number (23.28 ± 2.35 episodes) and latency (300 ± 0.00 s) of HD compared to normal rats (9.25 ± 1.37 episodes and 185.87 ± 35.44 s) when facing the greatest depth (30 cm). This suggests that HD may be a depth-measuring behavior related to risk assessment.
id UNSP_49548409518401cf1c2958d53444ea5a
oai_identifier_str oai:repositorio.unesp.br:11449/28074
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleusHead dippingRepetitive behaviorMedian raphe nucleusElectrolytic lesionRatHead dipping (HD) is a behavioral pattern considered to have a risk assessment or an exploratory role and is used as a complementary parameter to evaluate anxiety in experimental animals. Since rats with electrolytic lesion in the area of the median raphe nucleus displayed high frequencies of HD in a previous study, the present investigation was undertaken to confirm this observation and to determine its anxiety-related origin. HD episodes were counted in adult male Wistar rats (270-350 g) with electrolytic lesion (N = 11) and sham-lesioned controls (N = 12). When HD was measured for 60 min on an elevated open platform, lesioned rats emitted 13 times more HD than controls (264.7 ± 93.3 vs 20.3 ± 7.6 episodes), with the difference being statistically significant (P < 0.05). HD counts during 10-min sessions held 7, 14, 21, 27, and 63 days after lesion showed significantly higher means (range: 28.14 ± 5.38 to 62.85 ± 9.48) compared to sham-lesioned controls (range: 7.37 ± 1.13 to 8.5 ± 1.45). Normal rats stepped down into their home cages when the vertical distance between them and the cage was short (16 cm), and the step-down latencies increased with increasing depths (36.7 ± 7.92 to 185.87 ± 35.44 s). Lesioned rats showed a similar behavior when facing the shortest depth, but had a significantly increased number (23.28 ± 2.35 episodes) and latency (300 ± 0.00 s) of HD compared to normal rats (9.25 ± 1.37 episodes and 185.87 ± 35.44 s) when facing the greatest depth (30 cm). This suggests that HD may be a depth-measuring behavior related to risk assessment.Universidade Estadual Paulista Faculdade de Ciências Departamento de Ciências BiológicasUniversidade Estadual Paulista Faculdade de Ciências Departamento de Ciências BiológicasAssociação Brasileira de Divulgação Científica (ABRADIC)Universidade Estadual Paulista (Unesp)Hoshino, K. [UNESP]Uga, D.A. [UNESP]de Paula, H.M.G. [UNESP]2014-05-20T15:11:33Z2014-05-20T15:11:33Z2004-02-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article245-250application/pdfhttp://dx.doi.org/10.1590/S0100-879X2004000200012Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 37, n. 2, p. 245-250, 2004.0100-879Xhttp://hdl.handle.net/11449/2807410.1590/S0100-879X2004000200012S0100-879X20040002000122-s2.0-1442331009S0100-879X2004000200012.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Journal of Medical and Biological Research1.492info:eu-repo/semantics/openAccess2024-04-23T15:24:03Zoai:repositorio.unesp.br:11449/28074Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-06T00:13:23.602315Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
title The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
spellingShingle The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
Hoshino, K. [UNESP]
Head dipping
Repetitive behavior
Median raphe nucleus
Electrolytic lesion
Rat
title_short The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
title_full The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
title_fullStr The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
title_full_unstemmed The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
title_sort The compulsive-like aspect of the head dipping emission in rats with chronic electrolytic lesion in the area of the median raphe nucleus
author Hoshino, K. [UNESP]
author_facet Hoshino, K. [UNESP]
Uga, D.A. [UNESP]
de Paula, H.M.G. [UNESP]
author_role author
author2 Uga, D.A. [UNESP]
de Paula, H.M.G. [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Hoshino, K. [UNESP]
Uga, D.A. [UNESP]
de Paula, H.M.G. [UNESP]
dc.subject.por.fl_str_mv Head dipping
Repetitive behavior
Median raphe nucleus
Electrolytic lesion
Rat
topic Head dipping
Repetitive behavior
Median raphe nucleus
Electrolytic lesion
Rat
description Head dipping (HD) is a behavioral pattern considered to have a risk assessment or an exploratory role and is used as a complementary parameter to evaluate anxiety in experimental animals. Since rats with electrolytic lesion in the area of the median raphe nucleus displayed high frequencies of HD in a previous study, the present investigation was undertaken to confirm this observation and to determine its anxiety-related origin. HD episodes were counted in adult male Wistar rats (270-350 g) with electrolytic lesion (N = 11) and sham-lesioned controls (N = 12). When HD was measured for 60 min on an elevated open platform, lesioned rats emitted 13 times more HD than controls (264.7 ± 93.3 vs 20.3 ± 7.6 episodes), with the difference being statistically significant (P < 0.05). HD counts during 10-min sessions held 7, 14, 21, 27, and 63 days after lesion showed significantly higher means (range: 28.14 ± 5.38 to 62.85 ± 9.48) compared to sham-lesioned controls (range: 7.37 ± 1.13 to 8.5 ± 1.45). Normal rats stepped down into their home cages when the vertical distance between them and the cage was short (16 cm), and the step-down latencies increased with increasing depths (36.7 ± 7.92 to 185.87 ± 35.44 s). Lesioned rats showed a similar behavior when facing the shortest depth, but had a significantly increased number (23.28 ± 2.35 episodes) and latency (300 ± 0.00 s) of HD compared to normal rats (9.25 ± 1.37 episodes and 185.87 ± 35.44 s) when facing the greatest depth (30 cm). This suggests that HD may be a depth-measuring behavior related to risk assessment.
publishDate 2004
dc.date.none.fl_str_mv 2004-02-01
2014-05-20T15:11:33Z
2014-05-20T15:11:33Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0100-879X2004000200012
Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 37, n. 2, p. 245-250, 2004.
0100-879X
http://hdl.handle.net/11449/28074
10.1590/S0100-879X2004000200012
S0100-879X2004000200012
2-s2.0-1442331009
S0100-879X2004000200012.pdf
url http://dx.doi.org/10.1590/S0100-879X2004000200012
http://hdl.handle.net/11449/28074
identifier_str_mv Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 37, n. 2, p. 245-250, 2004.
0100-879X
10.1590/S0100-879X2004000200012
S0100-879X2004000200012
2-s2.0-1442331009
S0100-879X2004000200012.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Journal of Medical and Biological Research
1.492
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 245-250
application/pdf
dc.publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica (ABRADIC)
publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica (ABRADIC)
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129597304209408