Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis

Detalhes bibliográficos
Autor(a) principal: De Almeida, Antonio Alves [UNESP]
Data de Publicação: 2017
Outros Autores: Longhini, Diogo [UNESP], Suzuki, Paulo Atsushi, Ribeiro, Sebastião, Santos, Claudinei, Adabo, Gelson Luis [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/1980-5373-MR-2017-0190
http://hdl.handle.net/11449/175335
Resumo: To solve chipping of veneer porcelain in zirconia dental prosthesis it has been studied different cooling rates in firing schedules to control residual stresses generated by differences in thermal properties between the ceramics. However, cooling rates may affect the porcelain, irrespectively of interaction with zirconia. This study analyzed the effect of cooling rate on the three-point flexural strength (FS), residual stress, Vickers hardness (VH) and V-notch fracture toughness (SEVNB) on a feldspathic porcelain (Vita VM9) indicated for covering zirconia. Bar-shaped specimens were sintered according manufacturer's schedule firing and cooled at different rates (slow, normal or fast). Specimens were tested for FS (n=30), VH (n=15) and SEVNB tests (n=15). Weibull analysis were performed from FS values to measure reliability and probability of failure (PF). One-way ANOVA was significant for VH (p<0.001), and Tukey's test showed that slow cooling led to higher values. There was no significant difference for FS (p=0.654) and SEVNB (p=0.734). Fast cooling led to the lowest PF, but cooling rate factor was not significant for Weibull modulus. All cooling group showed residual tensile stress (MPa): Slow = 34.81; Normal = 27.04; Fast = 18,98. It was concluded that cooling rate produce minor changes in the porcelain properties.
id UNSP_4d4a71ea179d0672880a6a5d8b6b6087
oai_identifier_str oai:repositorio.unesp.br:11449/175335
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesisCoolingDental porcelainMaterial resistanceTo solve chipping of veneer porcelain in zirconia dental prosthesis it has been studied different cooling rates in firing schedules to control residual stresses generated by differences in thermal properties between the ceramics. However, cooling rates may affect the porcelain, irrespectively of interaction with zirconia. This study analyzed the effect of cooling rate on the three-point flexural strength (FS), residual stress, Vickers hardness (VH) and V-notch fracture toughness (SEVNB) on a feldspathic porcelain (Vita VM9) indicated for covering zirconia. Bar-shaped specimens were sintered according manufacturer's schedule firing and cooled at different rates (slow, normal or fast). Specimens were tested for FS (n=30), VH (n=15) and SEVNB tests (n=15). Weibull analysis were performed from FS values to measure reliability and probability of failure (PF). One-way ANOVA was significant for VH (p<0.001), and Tukey's test showed that slow cooling led to higher values. There was no significant difference for FS (p=0.654) and SEVNB (p=0.734). Fast cooling led to the lowest PF, but cooling rate factor was not significant for Weibull modulus. All cooling group showed residual tensile stress (MPa): Slow = 34.81; Normal = 27.04; Fast = 18,98. It was concluded that cooling rate produce minor changes in the porcelain properties.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Departamento de Materiais Odontológicos e Prótese Faculdade de Odontologia de Araraquara Universidade Estadual Paulista - UNESP, Rua Humaitá, 1680Departamento de Engenharia de Materiais Escola de Engenharia de Lorena Universidade de São Paulo - USP, Polo Urbo-industrial, Gleba AI-6Departamento de Engenharia de Materiais Faculdade de Tecnologia de Resende Universidade Estadual do Rio de Janeiro - UERJ, Rodovia Presidente Dutra, km 298 (sentido RJ-SP)Departamento de Materiais Odontológicos e Prótese Faculdade de Odontologia de Araraquara Universidade Estadual Paulista - UNESP, Rua Humaitá, 1680FAPESP: 2009/17735-8FAPESP: 2010/05469-9Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Universidade do Estado do Rio de Janeiro (UERJ)De Almeida, Antonio Alves [UNESP]Longhini, Diogo [UNESP]Suzuki, Paulo AtsushiRibeiro, SebastiãoSantos, ClaudineiAdabo, Gelson Luis [UNESP]2018-12-11T17:15:21Z2018-12-11T17:15:21Z2017-10-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1418-1424application/pdfhttp://dx.doi.org/10.1590/1980-5373-MR-2017-0190Materials Research, v. 20, n. 5, p. 1418-1424, 2017.1516-1439http://hdl.handle.net/11449/17533510.1590/1980-5373-MR-2017-0190S1516-143920170005014182-s2.0-85031276854S1516-14392017000501418.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMaterials Research0,398info:eu-repo/semantics/openAccess2023-11-27T06:09:59Zoai:repositorio.unesp.br:11449/175335Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-11-27T06:09:59Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
title Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
spellingShingle Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
De Almeida, Antonio Alves [UNESP]
Cooling
Dental porcelain
Material resistance
title_short Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
title_full Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
title_fullStr Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
title_full_unstemmed Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
title_sort Effect of the cooling rate on the properties of veneer porcelain for zirconia dental prosthesis
author De Almeida, Antonio Alves [UNESP]
author_facet De Almeida, Antonio Alves [UNESP]
Longhini, Diogo [UNESP]
Suzuki, Paulo Atsushi
Ribeiro, Sebastião
Santos, Claudinei
Adabo, Gelson Luis [UNESP]
author_role author
author2 Longhini, Diogo [UNESP]
Suzuki, Paulo Atsushi
Ribeiro, Sebastião
Santos, Claudinei
Adabo, Gelson Luis [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
Universidade do Estado do Rio de Janeiro (UERJ)
dc.contributor.author.fl_str_mv De Almeida, Antonio Alves [UNESP]
Longhini, Diogo [UNESP]
Suzuki, Paulo Atsushi
Ribeiro, Sebastião
Santos, Claudinei
Adabo, Gelson Luis [UNESP]
dc.subject.por.fl_str_mv Cooling
Dental porcelain
Material resistance
topic Cooling
Dental porcelain
Material resistance
description To solve chipping of veneer porcelain in zirconia dental prosthesis it has been studied different cooling rates in firing schedules to control residual stresses generated by differences in thermal properties between the ceramics. However, cooling rates may affect the porcelain, irrespectively of interaction with zirconia. This study analyzed the effect of cooling rate on the three-point flexural strength (FS), residual stress, Vickers hardness (VH) and V-notch fracture toughness (SEVNB) on a feldspathic porcelain (Vita VM9) indicated for covering zirconia. Bar-shaped specimens were sintered according manufacturer's schedule firing and cooled at different rates (slow, normal or fast). Specimens were tested for FS (n=30), VH (n=15) and SEVNB tests (n=15). Weibull analysis were performed from FS values to measure reliability and probability of failure (PF). One-way ANOVA was significant for VH (p<0.001), and Tukey's test showed that slow cooling led to higher values. There was no significant difference for FS (p=0.654) and SEVNB (p=0.734). Fast cooling led to the lowest PF, but cooling rate factor was not significant for Weibull modulus. All cooling group showed residual tensile stress (MPa): Slow = 34.81; Normal = 27.04; Fast = 18,98. It was concluded that cooling rate produce minor changes in the porcelain properties.
publishDate 2017
dc.date.none.fl_str_mv 2017-10-01
2018-12-11T17:15:21Z
2018-12-11T17:15:21Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1980-5373-MR-2017-0190
Materials Research, v. 20, n. 5, p. 1418-1424, 2017.
1516-1439
http://hdl.handle.net/11449/175335
10.1590/1980-5373-MR-2017-0190
S1516-14392017000501418
2-s2.0-85031276854
S1516-14392017000501418.pdf
url http://dx.doi.org/10.1590/1980-5373-MR-2017-0190
http://hdl.handle.net/11449/175335
identifier_str_mv Materials Research, v. 20, n. 5, p. 1418-1424, 2017.
1516-1439
10.1590/1980-5373-MR-2017-0190
S1516-14392017000501418
2-s2.0-85031276854
S1516-14392017000501418.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Materials Research
0,398
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1418-1424
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803046676822228992