Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/1517-7076-RMAT-2022-0183 http://hdl.handle.net/11449/249588 |
Resumo: | The passivation level of AISI 316L bioprocessing tanks of roughness average of 0.8 μm mechanically polished was assessed. The on-site inspections were performed after tanks manufacturing and in distinct surface conditions: (i) after 12 months of industrial operation, (ii) with biofilm adhesion, (iii) after chemical passivation treatment. The PassivityScan inspection instrument was used in on-site measurements of passivation level applying the open circuit potential and cyclic potentiodynamic polarization techniques. The results showed that the tank inner surface in as-built condition obtained a relative low passivation level (Eprot –Ecorr < 150 mV(Ag|AgCl|KCl 3 mol/L) and high corrosion kinetic. The passivation level and durability of the surface were reduced after 12 months of operation. A worst-case scenario was noted with biofilm adhesion given that the surface was not able to repassivate. It worth to emphasize that the passivation treatment increased the passivation level to 520 mV(Ag|AgCl|KCl 3 mol/L) and reduced the passivation current density from 20 to 0.7 μA cm–2. It was concluded that a passivated AISI 316L tank reach a better operational reliability, and also the chemical passivation treatment should be done every 12 months in order to restorage the passive film resistance. |
id |
UNSP_4e160f41fd4b0c2ad6192fcd6f4b05a2 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/249588 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurementsQualificação da superfície de tanques de bioprocessamento assépticAISI 316L utilizando medidas eletroquímicas in situ316L stainless steelBioprocessing tankOn-site inspectionPassivation levelThe passivation level of AISI 316L bioprocessing tanks of roughness average of 0.8 μm mechanically polished was assessed. The on-site inspections were performed after tanks manufacturing and in distinct surface conditions: (i) after 12 months of industrial operation, (ii) with biofilm adhesion, (iii) after chemical passivation treatment. The PassivityScan inspection instrument was used in on-site measurements of passivation level applying the open circuit potential and cyclic potentiodynamic polarization techniques. The results showed that the tank inner surface in as-built condition obtained a relative low passivation level (Eprot –Ecorr < 150 mV(Ag|AgCl|KCl 3 mol/L) and high corrosion kinetic. The passivation level and durability of the surface were reduced after 12 months of operation. A worst-case scenario was noted with biofilm adhesion given that the surface was not able to repassivate. It worth to emphasize that the passivation treatment increased the passivation level to 520 mV(Ag|AgCl|KCl 3 mol/L) and reduced the passivation current density from 20 to 0.7 μA cm–2. It was concluded that a passivated AISI 316L tank reach a better operational reliability, and also the chemical passivation treatment should be done every 12 months in order to restorage the passive film resistance.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)ACW Engenharia Departamento P&D, Av. Armando Correa de Siqueira, 1708, SPUniversidade Estadual Paulista Instituto de Química, Av. Prof. Francisco Degni, 55, SPUniversidade Estadual Paulista Instituto de Química, Av. Prof. Francisco Degni, 55, SPFAPESP: 2021/11684-4ACW EngenhariaUniversidade Estadual Paulista (UNESP)Guilherme, Luís HenriqueFugivara, Cecílio Sadao [UNESP]Benedetti, Assis Vicente [UNESP]2023-07-29T16:03:47Z2023-07-29T16:03:47Z2022-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1590/1517-7076-RMAT-2022-0183Revista Materia, v. 27, n. 4, 2022.1517-7076http://hdl.handle.net/11449/24958810.1590/1517-7076-RMAT-2022-01832-s2.0-85146746175Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporRevista Materiainfo:eu-repo/semantics/openAccess2023-07-29T16:03:47Zoai:repositorio.unesp.br:11449/249588Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:32:07.068723Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements Qualificação da superfície de tanques de bioprocessamento assépticAISI 316L utilizando medidas eletroquímicas in situ |
title |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements |
spellingShingle |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements Guilherme, Luís Henrique 316L stainless steel Bioprocessing tank On-site inspection Passivation level |
title_short |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements |
title_full |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements |
title_fullStr |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements |
title_full_unstemmed |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements |
title_sort |
Surface qualification of AISI 316L bioprocessing tanks applying on-sitelectrochemical measurements |
author |
Guilherme, Luís Henrique |
author_facet |
Guilherme, Luís Henrique Fugivara, Cecílio Sadao [UNESP] Benedetti, Assis Vicente [UNESP] |
author_role |
author |
author2 |
Fugivara, Cecílio Sadao [UNESP] Benedetti, Assis Vicente [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
ACW Engenharia Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Guilherme, Luís Henrique Fugivara, Cecílio Sadao [UNESP] Benedetti, Assis Vicente [UNESP] |
dc.subject.por.fl_str_mv |
316L stainless steel Bioprocessing tank On-site inspection Passivation level |
topic |
316L stainless steel Bioprocessing tank On-site inspection Passivation level |
description |
The passivation level of AISI 316L bioprocessing tanks of roughness average of 0.8 μm mechanically polished was assessed. The on-site inspections were performed after tanks manufacturing and in distinct surface conditions: (i) after 12 months of industrial operation, (ii) with biofilm adhesion, (iii) after chemical passivation treatment. The PassivityScan inspection instrument was used in on-site measurements of passivation level applying the open circuit potential and cyclic potentiodynamic polarization techniques. The results showed that the tank inner surface in as-built condition obtained a relative low passivation level (Eprot –Ecorr < 150 mV(Ag|AgCl|KCl 3 mol/L) and high corrosion kinetic. The passivation level and durability of the surface were reduced after 12 months of operation. A worst-case scenario was noted with biofilm adhesion given that the surface was not able to repassivate. It worth to emphasize that the passivation treatment increased the passivation level to 520 mV(Ag|AgCl|KCl 3 mol/L) and reduced the passivation current density from 20 to 0.7 μA cm–2. It was concluded that a passivated AISI 316L tank reach a better operational reliability, and also the chemical passivation treatment should be done every 12 months in order to restorage the passive film resistance. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-01 2023-07-29T16:03:47Z 2023-07-29T16:03:47Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/1517-7076-RMAT-2022-0183 Revista Materia, v. 27, n. 4, 2022. 1517-7076 http://hdl.handle.net/11449/249588 10.1590/1517-7076-RMAT-2022-0183 2-s2.0-85146746175 |
url |
http://dx.doi.org/10.1590/1517-7076-RMAT-2022-0183 http://hdl.handle.net/11449/249588 |
identifier_str_mv |
Revista Materia, v. 27, n. 4, 2022. 1517-7076 10.1590/1517-7076-RMAT-2022-0183 2-s2.0-85146746175 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Revista Materia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128528813654016 |