Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis

Detalhes bibliográficos
Autor(a) principal: De Arruda Paes-Junior, Tarcisio José [UNESP]
Data de Publicação: 2021
Outros Autores: Tribst, João Paulo Mendes [UNESP], Dal Piva, Amanda Maria De Oliveira [UNESP], Figueiredo, Viviane Maria Gonçalves De, Borges, Alexandre Luiz Souto [UNESP], Inagati, Cristiane Mayumi [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.14295/bds.2021.v24i2.2144
http://hdl.handle.net/11449/208613
Resumo: Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain.
id UNSP_4f335bcf1084a774f8b37b1601894f89
oai_identifier_str oai:repositorio.unesp.br:11449/208613
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysisFinite element analysisOcclusionTotal prosthesisPurpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain.Department of Dental Materials and Prosthetics São Paulo State University (UNESP) Institute of Science and Technology São José dos Campos Dental SchoolDepartment of Prosthesis and Oral-Facial Surgery Pernambuco Federal University (UFPE). RecifeDepartment of Dental Materials and Prosthetics São Paulo State University (UNESP) Institute of Science and Technology São José dos Campos Dental SchoolUniversidade Estadual Paulista (Unesp)Universidade Federal de Pernambuco (UFPE)De Arruda Paes-Junior, Tarcisio José [UNESP]Tribst, João Paulo Mendes [UNESP]Dal Piva, Amanda Maria De Oliveira [UNESP]Figueiredo, Viviane Maria Gonçalves DeBorges, Alexandre Luiz Souto [UNESP]Inagati, Cristiane Mayumi [UNESP]2021-06-25T11:15:00Z2021-06-25T11:15:00Z2021-04-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1-7http://dx.doi.org/10.14295/bds.2021.v24i2.2144Brazilian Dental Science, v. 24, n. 2, p. 1-7, 2021.2178-6011http://hdl.handle.net/11449/20861310.14295/bds.2021.v24i2.21442-s2.0-85104841367Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Scienceinfo:eu-repo/semantics/openAccess2021-10-23T19:02:17Zoai:repositorio.unesp.br:11449/208613Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T18:39:10.317619Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
title Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
spellingShingle Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
De Arruda Paes-Junior, Tarcisio José [UNESP]
Finite element analysis
Occlusion
Total prosthesis
title_short Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
title_full Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
title_fullStr Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
title_full_unstemmed Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
title_sort Influence of fibromucosa height and loading on the stress distribution of a total prosthesis: A finite element analysis
author De Arruda Paes-Junior, Tarcisio José [UNESP]
author_facet De Arruda Paes-Junior, Tarcisio José [UNESP]
Tribst, João Paulo Mendes [UNESP]
Dal Piva, Amanda Maria De Oliveira [UNESP]
Figueiredo, Viviane Maria Gonçalves De
Borges, Alexandre Luiz Souto [UNESP]
Inagati, Cristiane Mayumi [UNESP]
author_role author
author2 Tribst, João Paulo Mendes [UNESP]
Dal Piva, Amanda Maria De Oliveira [UNESP]
Figueiredo, Viviane Maria Gonçalves De
Borges, Alexandre Luiz Souto [UNESP]
Inagati, Cristiane Mayumi [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade Federal de Pernambuco (UFPE)
dc.contributor.author.fl_str_mv De Arruda Paes-Junior, Tarcisio José [UNESP]
Tribst, João Paulo Mendes [UNESP]
Dal Piva, Amanda Maria De Oliveira [UNESP]
Figueiredo, Viviane Maria Gonçalves De
Borges, Alexandre Luiz Souto [UNESP]
Inagati, Cristiane Mayumi [UNESP]
dc.subject.por.fl_str_mv Finite element analysis
Occlusion
Total prosthesis
topic Finite element analysis
Occlusion
Total prosthesis
description Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-25T11:15:00Z
2021-06-25T11:15:00Z
2021-04-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.14295/bds.2021.v24i2.2144
Brazilian Dental Science, v. 24, n. 2, p. 1-7, 2021.
2178-6011
http://hdl.handle.net/11449/208613
10.14295/bds.2021.v24i2.2144
2-s2.0-85104841367
url http://dx.doi.org/10.14295/bds.2021.v24i2.2144
http://hdl.handle.net/11449/208613
identifier_str_mv Brazilian Dental Science, v. 24, n. 2, p. 1-7, 2021.
2178-6011
10.14295/bds.2021.v24i2.2144
2-s2.0-85104841367
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Dental Science
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1-7
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128960068845568