Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1016/j.jdent.2012.01.001 http://hdl.handle.net/11449/16550 |
Resumo: | Objectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride.Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05).Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces.Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved. |
id |
UNSP_510ce97242d7e24dda458d29f33a894a |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/16550 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of useTitaniumSodium fluorideToothbrushingSurface propertiesMicroscopy atomic forceCorrosionObjectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride.Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05).Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces.Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)UNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, BrazilUniv São Paulo, Dept Phys & Mat Sci, BR-13566590 São Paulo, BrazilUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, BrazilFAPESP: 08/028710Elsevier B.V.Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Fais, Laiza M. G. [UNESP]Fernandes-Filho, Romeu B. [UNESP]Pereira-da-Silva, Marcelo A.Vaz, Luis Geraldo [UNESP]Adabo, Gelson Luis [UNESP]2014-05-20T13:46:43Z2014-05-20T13:46:43Z2012-04-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article265-275application/pdfhttp://dx.doi.org/10.1016/j.jdent.2012.01.001Journal of Dentistry. Oxford: Elsevier B.V., v. 40, n. 4, p. 265-275, 2012.0300-5712http://hdl.handle.net/11449/1655010.1016/j.jdent.2012.01.001WOS:000300954900001WOS000300954900001.pdf85477475564460202851339311179809Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Dentistry3.7701,919info:eu-repo/semantics/openAccess2024-09-27T14:56:29Zoai:repositorio.unesp.br:11449/16550Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T14:56:29Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
title |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
spellingShingle |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use Fais, Laiza M. G. [UNESP] Titanium Sodium fluoride Toothbrushing Surface properties Microscopy atomic force Corrosion |
title_short |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
title_full |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
title_fullStr |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
title_full_unstemmed |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
title_sort |
Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use |
author |
Fais, Laiza M. G. [UNESP] |
author_facet |
Fais, Laiza M. G. [UNESP] Fernandes-Filho, Romeu B. [UNESP] Pereira-da-Silva, Marcelo A. Vaz, Luis Geraldo [UNESP] Adabo, Gelson Luis [UNESP] |
author_role |
author |
author2 |
Fernandes-Filho, Romeu B. [UNESP] Pereira-da-Silva, Marcelo A. Vaz, Luis Geraldo [UNESP] Adabo, Gelson Luis [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Fais, Laiza M. G. [UNESP] Fernandes-Filho, Romeu B. [UNESP] Pereira-da-Silva, Marcelo A. Vaz, Luis Geraldo [UNESP] Adabo, Gelson Luis [UNESP] |
dc.subject.por.fl_str_mv |
Titanium Sodium fluoride Toothbrushing Surface properties Microscopy atomic force Corrosion |
topic |
Titanium Sodium fluoride Toothbrushing Surface properties Microscopy atomic force Corrosion |
description |
Objectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride.Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05).Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces.Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-04-01 2014-05-20T13:46:43Z 2014-05-20T13:46:43Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.jdent.2012.01.001 Journal of Dentistry. Oxford: Elsevier B.V., v. 40, n. 4, p. 265-275, 2012. 0300-5712 http://hdl.handle.net/11449/16550 10.1016/j.jdent.2012.01.001 WOS:000300954900001 WOS000300954900001.pdf 8547747556446020 2851339311179809 |
url |
http://dx.doi.org/10.1016/j.jdent.2012.01.001 http://hdl.handle.net/11449/16550 |
identifier_str_mv |
Journal of Dentistry. Oxford: Elsevier B.V., v. 40, n. 4, p. 265-275, 2012. 0300-5712 10.1016/j.jdent.2012.01.001 WOS:000300954900001 WOS000300954900001.pdf 8547747556446020 2851339311179809 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Dentistry 3.770 1,919 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
265-275 application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier B.V. |
publisher.none.fl_str_mv |
Elsevier B.V. |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546392562434048 |