Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use

Detalhes bibliográficos
Autor(a) principal: Fais, Laiza M. G. [UNESP]
Data de Publicação: 2012
Outros Autores: Fernandes-Filho, Romeu B. [UNESP], Pereira-da-Silva, Marcelo A., Vaz, Luis Geraldo [UNESP], Adabo, Gelson Luis [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.jdent.2012.01.001
http://hdl.handle.net/11449/16550
Resumo: Objectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride.Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05).Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces.Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved.
id UNSP_510ce97242d7e24dda458d29f33a894a
oai_identifier_str oai:repositorio.unesp.br:11449/16550
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of useTitaniumSodium fluorideToothbrushingSurface propertiesMicroscopy atomic forceCorrosionObjectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride.Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05).Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces.Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)UNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, BrazilUniv São Paulo, Dept Phys & Mat Sci, BR-13566590 São Paulo, BrazilUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, BrazilFAPESP: 08/028710Elsevier B.V.Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Fais, Laiza M. G. [UNESP]Fernandes-Filho, Romeu B. [UNESP]Pereira-da-Silva, Marcelo A.Vaz, Luis Geraldo [UNESP]Adabo, Gelson Luis [UNESP]2014-05-20T13:46:43Z2014-05-20T13:46:43Z2012-04-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article265-275application/pdfhttp://dx.doi.org/10.1016/j.jdent.2012.01.001Journal of Dentistry. Oxford: Elsevier B.V., v. 40, n. 4, p. 265-275, 2012.0300-5712http://hdl.handle.net/11449/1655010.1016/j.jdent.2012.01.001WOS:000300954900001WOS000300954900001.pdf85477475564460202851339311179809Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Dentistry3.7701,919info:eu-repo/semantics/openAccess2024-09-27T14:56:29Zoai:repositorio.unesp.br:11449/16550Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T14:56:29Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
title Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
spellingShingle Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
Fais, Laiza M. G. [UNESP]
Titanium
Sodium fluoride
Toothbrushing
Surface properties
Microscopy atomic force
Corrosion
title_short Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
title_full Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
title_fullStr Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
title_full_unstemmed Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
title_sort Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use
author Fais, Laiza M. G. [UNESP]
author_facet Fais, Laiza M. G. [UNESP]
Fernandes-Filho, Romeu B. [UNESP]
Pereira-da-Silva, Marcelo A.
Vaz, Luis Geraldo [UNESP]
Adabo, Gelson Luis [UNESP]
author_role author
author2 Fernandes-Filho, Romeu B. [UNESP]
Pereira-da-Silva, Marcelo A.
Vaz, Luis Geraldo [UNESP]
Adabo, Gelson Luis [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Fais, Laiza M. G. [UNESP]
Fernandes-Filho, Romeu B. [UNESP]
Pereira-da-Silva, Marcelo A.
Vaz, Luis Geraldo [UNESP]
Adabo, Gelson Luis [UNESP]
dc.subject.por.fl_str_mv Titanium
Sodium fluoride
Toothbrushing
Surface properties
Microscopy atomic force
Corrosion
topic Titanium
Sodium fluoride
Toothbrushing
Surface properties
Microscopy atomic force
Corrosion
description Objectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride.Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05).Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces.Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved.
publishDate 2012
dc.date.none.fl_str_mv 2012-04-01
2014-05-20T13:46:43Z
2014-05-20T13:46:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.jdent.2012.01.001
Journal of Dentistry. Oxford: Elsevier B.V., v. 40, n. 4, p. 265-275, 2012.
0300-5712
http://hdl.handle.net/11449/16550
10.1016/j.jdent.2012.01.001
WOS:000300954900001
WOS000300954900001.pdf
8547747556446020
2851339311179809
url http://dx.doi.org/10.1016/j.jdent.2012.01.001
http://hdl.handle.net/11449/16550
identifier_str_mv Journal of Dentistry. Oxford: Elsevier B.V., v. 40, n. 4, p. 265-275, 2012.
0300-5712
10.1016/j.jdent.2012.01.001
WOS:000300954900001
WOS000300954900001.pdf
8547747556446020
2851339311179809
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Dentistry
3.770
1,919
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 265-275
application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546392562434048