Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing

Detalhes bibliográficos
Autor(a) principal: de Alcantara, Naasson P. [UNESP]
Data de Publicação: 2015
Outros Autores: da Silva, Felipe M. [UNESP], Guimarães, Mateus T. [UNESP], Pereira, Matheus D. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.3390/s16010015
http://hdl.handle.net/11449/168254
Resumo: This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT) to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works.
id UNSP_531ce0a80b594a4d557792a4de47e933
oai_identifier_str oai:repositorio.unesp.br:11449/168254
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testingAccelerated corrosion techniquesCorrosion processEddy current testingNondestructive testingReinforced concrete structuresThis paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT) to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works.Department of Electrical Engineering São Paulo State University—UnespDepartment of Electrical Engineering São Paulo State University—UnespUniversidade Estadual Paulista (Unesp)de Alcantara, Naasson P. [UNESP]da Silva, Felipe M. [UNESP]Guimarães, Mateus T. [UNESP]Pereira, Matheus D. [UNESP]2018-12-11T16:40:27Z2018-12-11T16:40:27Z2015-12-24info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://dx.doi.org/10.3390/s16010015Sensors (Switzerland), v. 16, n. 1, 2015.1424-8220http://hdl.handle.net/11449/16825410.3390/s160100152-s2.0-849520314992-s2.0-84952031499.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengSensors (Switzerland)0,584info:eu-repo/semantics/openAccess2024-01-25T06:30:47Zoai:repositorio.unesp.br:11449/168254Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-01-25T06:30:47Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
title Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
spellingShingle Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
de Alcantara, Naasson P. [UNESP]
Accelerated corrosion techniques
Corrosion process
Eddy current testing
Nondestructive testing
Reinforced concrete structures
title_short Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
title_full Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
title_fullStr Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
title_full_unstemmed Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
title_sort Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing
author de Alcantara, Naasson P. [UNESP]
author_facet de Alcantara, Naasson P. [UNESP]
da Silva, Felipe M. [UNESP]
Guimarães, Mateus T. [UNESP]
Pereira, Matheus D. [UNESP]
author_role author
author2 da Silva, Felipe M. [UNESP]
Guimarães, Mateus T. [UNESP]
Pereira, Matheus D. [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv de Alcantara, Naasson P. [UNESP]
da Silva, Felipe M. [UNESP]
Guimarães, Mateus T. [UNESP]
Pereira, Matheus D. [UNESP]
dc.subject.por.fl_str_mv Accelerated corrosion techniques
Corrosion process
Eddy current testing
Nondestructive testing
Reinforced concrete structures
topic Accelerated corrosion techniques
Corrosion process
Eddy current testing
Nondestructive testing
Reinforced concrete structures
description This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT) to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-24
2018-12-11T16:40:27Z
2018-12-11T16:40:27Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.3390/s16010015
Sensors (Switzerland), v. 16, n. 1, 2015.
1424-8220
http://hdl.handle.net/11449/168254
10.3390/s16010015
2-s2.0-84952031499
2-s2.0-84952031499.pdf
url http://dx.doi.org/10.3390/s16010015
http://hdl.handle.net/11449/168254
identifier_str_mv Sensors (Switzerland), v. 16, n. 1, 2015.
1424-8220
10.3390/s16010015
2-s2.0-84952031499
2-s2.0-84952031499.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Sensors (Switzerland)
0,584
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1826304658746900480