Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA

Detalhes bibliográficos
Autor(a) principal: Boni, Ana Carolina [UNESP]
Data de Publicação: 2011
Outros Autores: Wong, Ademar [UNESP], Fireman Dutra, Rosa Amalia, Taboada Sotomayor, Maria Del Pilar [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.talanta.2011.07.038
http://hdl.handle.net/11449/25981
Resumo: A biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min(-1), a 75 mu L sample loop, a 0.1 mol L-1 phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 x 10(-6)-6.3 x 10(-3) mol L-1. Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone. (C) 2011 Elsevier B.V. All rights reserved.
id UNSP_62e356cef9adf2cb901b2c3c76be9e60
oai_identifier_str oai:repositorio.unesp.br:11449/25981
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIABiomimetic catalystCobalt phthalocyanineDipyroneFlow injection systemA biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min(-1), a 75 mu L sample loop, a 0.1 mol L-1 phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 x 10(-6)-6.3 x 10(-3) mol L-1. Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone. (C) 2011 Elsevier B.V. All rights reserved.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)State Univ São Paulo UNESP, Dept Analyt Chem, Inst Chem, BR-14801970 Araraquara, SP, BrazilUniv Pernambuco, Lab Diagnost Res IAPED, BR-50100130 Recife, PE, BrazilState Univ São Paulo UNESP, Dept Analyt Chem, Inst Chem, BR-14801970 Araraquara, SP, BrazilFAPESP: 08/00303-5FAPESP: 09/04598-2Elsevier B.V.Universidade Estadual Paulista (Unesp)Univ PernambucoBoni, Ana Carolina [UNESP]Wong, Ademar [UNESP]Fireman Dutra, Rosa AmaliaTaboada Sotomayor, Maria Del Pilar [UNESP]2014-05-20T14:19:54Z2014-05-20T14:19:54Z2011-09-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article2067-2073application/pdfhttp://dx.doi.org/10.1016/j.talanta.2011.07.038Talanta. Amsterdam: Elsevier B.V., v. 85, n. 4, p. 2067-2073, 2011.0039-9140http://hdl.handle.net/11449/2598110.1016/j.talanta.2011.07.038WOS:000295393000054WOS000295393000054.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengTalanta4.2441,186info:eu-repo/semantics/openAccess2024-01-18T06:30:26Zoai:repositorio.unesp.br:11449/25981Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T23:22:10.769629Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
title Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
spellingShingle Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
Boni, Ana Carolina [UNESP]
Biomimetic catalyst
Cobalt phthalocyanine
Dipyrone
Flow injection system
title_short Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
title_full Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
title_fullStr Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
title_full_unstemmed Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
title_sort Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
author Boni, Ana Carolina [UNESP]
author_facet Boni, Ana Carolina [UNESP]
Wong, Ademar [UNESP]
Fireman Dutra, Rosa Amalia
Taboada Sotomayor, Maria Del Pilar [UNESP]
author_role author
author2 Wong, Ademar [UNESP]
Fireman Dutra, Rosa Amalia
Taboada Sotomayor, Maria Del Pilar [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Univ Pernambuco
dc.contributor.author.fl_str_mv Boni, Ana Carolina [UNESP]
Wong, Ademar [UNESP]
Fireman Dutra, Rosa Amalia
Taboada Sotomayor, Maria Del Pilar [UNESP]
dc.subject.por.fl_str_mv Biomimetic catalyst
Cobalt phthalocyanine
Dipyrone
Flow injection system
topic Biomimetic catalyst
Cobalt phthalocyanine
Dipyrone
Flow injection system
description A biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min(-1), a 75 mu L sample loop, a 0.1 mol L-1 phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 x 10(-6)-6.3 x 10(-3) mol L-1. Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone. (C) 2011 Elsevier B.V. All rights reserved.
publishDate 2011
dc.date.none.fl_str_mv 2011-09-30
2014-05-20T14:19:54Z
2014-05-20T14:19:54Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.talanta.2011.07.038
Talanta. Amsterdam: Elsevier B.V., v. 85, n. 4, p. 2067-2073, 2011.
0039-9140
http://hdl.handle.net/11449/25981
10.1016/j.talanta.2011.07.038
WOS:000295393000054
WOS000295393000054.pdf
url http://dx.doi.org/10.1016/j.talanta.2011.07.038
http://hdl.handle.net/11449/25981
identifier_str_mv Talanta. Amsterdam: Elsevier B.V., v. 85, n. 4, p. 2067-2073, 2011.
0039-9140
10.1016/j.talanta.2011.07.038
WOS:000295393000054
WOS000295393000054.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Talanta
4.244
1,186
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 2067-2073
application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129512045543424