Acoustic and psychoacoustic analysis of the noise produced by the police force firearms

Detalhes bibliográficos
Autor(a) principal: Guida, Heraldo Lorena [UNESP]
Data de Publicação: 2011
Outros Autores: Diniz, Thiago Hernandes [UNESP], Kinoshita, Sergio Koodi [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942011000200005&lng=pt&nrm=iso&tlng=pt
http://hdl.handle.net/11449/10755
Resumo: Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.
id UNSP_6401ca6053023216b96d91fca53b54d6
oai_identifier_str oai:repositorio.unesp.br:11449/10755
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Acoustic and psychoacoustic analysis of the noise produced by the police force firearmsAnálise acústica e psicoacústica do ruído de armas utilizadas pela Polícia MilitarfirearmspolicenoiseoccupationalPolice officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.Os policiais militares estão expostos a ruídos de impacto provenientes de armas de fogo, os quais são capazes de causar lesões irreversíveis ao sistema auditivo. OBJETIVO: Avaliar a exposição ao ruído no estande de tiros durante os exercícios de tiro, analisar acusticamente o ruído de impacto e relacioná-lo com os resultados de audiometria tonal. FORMA DE ESTUDO: Transversal. MATERIAL E MÉTODO: A medição do ruído foi feita por meio de decibelímetro digital e a análise acústica foi feita no software Praat, levantando as curvas de oscilograma e cocleograma. Foi selecionada uma amostra de 30 policiais militares (27 masculinos e 3 femininos). RESULTADOS: Os picos máximos medidos no estante de tiros foram de 113,1 dB(C) para pistola .40 e 116,8 dB(C) para revólver .38. Os valores obtidos por meio da relação entre o oscilograma temporal e cocleograma Praat ficaram entre 17,9±0,3 Barks, correspondendo à faixa entre 4120 e 4580 Hz. As medidas da audiometria indicaram maior perda auditiva na faixa de 4000Hz em 86,7% dos casos. CONCLUSÃO: A partir da análise acústica dos tiros, foi possível demonstrar causa e efeito entre as principais áreas de excitação de energia na cóclea (cocleograma Praat) e as frequências com diminuição de acuidade auditiva.Univ Estadual Paulista, Fac Filosofia & Ciencias, BR-17525900 São Paulo, BrazilUniv Estadual Paulista, Fac Filosofia & Ciencias, BR-17525900 São Paulo, BrazilAssoc Brasileira Otorrinolaringologia & Cirurgia CervicofacialUniversidade Estadual Paulista (Unesp)Guida, Heraldo Lorena [UNESP]Diniz, Thiago Hernandes [UNESP]Kinoshita, Sergio Koodi [UNESP]2014-05-20T13:31:34Z2014-05-20T13:31:34Z2011-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article163-170application/pdfapplication/pdfhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942011000200005&lng=pt&nrm=iso&tlng=ptBrazilian Journal of Otorhinolaryngology. São Paulo: Assoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial, v. 77, n. 2, p. 163-170, 2011.1808-8694http://hdl.handle.net/11449/10755S1808-86942011000200005WOS:000293578500005S1808-86942011000200005-pt.pdfS1808-86942011000200005-en.pdf2545336847709120Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Journal of Otorhinolaryngology1.4120,443info:eu-repo/semantics/openAccess2023-10-26T06:11:26Zoai:repositorio.unesp.br:11449/10755Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-10-26T06:11:26Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
Análise acústica e psicoacústica do ruído de armas utilizadas pela Polícia Militar
title Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
spellingShingle Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
Guida, Heraldo Lorena [UNESP]
firearms
police
noise
occupational
title_short Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
title_full Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
title_fullStr Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
title_full_unstemmed Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
title_sort Acoustic and psychoacoustic analysis of the noise produced by the police force firearms
author Guida, Heraldo Lorena [UNESP]
author_facet Guida, Heraldo Lorena [UNESP]
Diniz, Thiago Hernandes [UNESP]
Kinoshita, Sergio Koodi [UNESP]
author_role author
author2 Diniz, Thiago Hernandes [UNESP]
Kinoshita, Sergio Koodi [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Guida, Heraldo Lorena [UNESP]
Diniz, Thiago Hernandes [UNESP]
Kinoshita, Sergio Koodi [UNESP]
dc.subject.por.fl_str_mv firearms
police
noise
occupational
topic firearms
police
noise
occupational
description Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.
publishDate 2011
dc.date.none.fl_str_mv 2011-03-01
2014-05-20T13:31:34Z
2014-05-20T13:31:34Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942011000200005&lng=pt&nrm=iso&tlng=pt
Brazilian Journal of Otorhinolaryngology. São Paulo: Assoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial, v. 77, n. 2, p. 163-170, 2011.
1808-8694
http://hdl.handle.net/11449/10755
S1808-86942011000200005
WOS:000293578500005
S1808-86942011000200005-pt.pdf
S1808-86942011000200005-en.pdf
2545336847709120
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942011000200005&lng=pt&nrm=iso&tlng=pt
http://hdl.handle.net/11449/10755
identifier_str_mv Brazilian Journal of Otorhinolaryngology. São Paulo: Assoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial, v. 77, n. 2, p. 163-170, 2011.
1808-8694
S1808-86942011000200005
WOS:000293578500005
S1808-86942011000200005-pt.pdf
S1808-86942011000200005-en.pdf
2545336847709120
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Journal of Otorhinolaryngology
1.412
0,443
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 163-170
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Assoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial
publisher.none.fl_str_mv Assoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799964710357958656