Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/226990 |
Resumo: | A method is proposed for the simultaneous determination Cd and Pb in medicinal plants using direct slurry sampling by GF-AAS. The thermal behavior of analytes was checked in aqueous and slurry media using Ir permanent modifier. The optimized pyrolysis (1000 °C and atomization (2200 °C) temperatures allowed calibration using aqueous standards. For a 20-μL injected volume, the calculated characteristic mass was 1.8 pg for Cd and 59 pg for Pb. The relative standard deviation (n=12) for Cd and Pb was 5.3% and 3-5%, respectively. The limit of detection was 0.12 pg L -1 for Cd and 1.22 μg L -1 for Pb. Accuracy was checked by analyzing the standard reference materials Ginkgo Biloba Leaves, Peach Leaves, and Pine Needles. The results obtained for the analytes were in agreement with the certified values at the 95% confidence level. Ten medicinal plant samples were analyzed and the found concentrations ranged from 0.19-0.34 μg g -1 for Cd and 1.02-1.91 μg g -1 for Pb. |
id |
UNSP_6fcc13bd588ce29ae4ceddb36d700374 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/226990 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry samplingA method is proposed for the simultaneous determination Cd and Pb in medicinal plants using direct slurry sampling by GF-AAS. The thermal behavior of analytes was checked in aqueous and slurry media using Ir permanent modifier. The optimized pyrolysis (1000 °C and atomization (2200 °C) temperatures allowed calibration using aqueous standards. For a 20-μL injected volume, the calculated characteristic mass was 1.8 pg for Cd and 59 pg for Pb. The relative standard deviation (n=12) for Cd and Pb was 5.3% and 3-5%, respectively. The limit of detection was 0.12 pg L -1 for Cd and 1.22 μg L -1 for Pb. Accuracy was checked by analyzing the standard reference materials Ginkgo Biloba Leaves, Peach Leaves, and Pine Needles. The results obtained for the analytes were in agreement with the certified values at the 95% confidence level. Ten medicinal plant samples were analyzed and the found concentrations ranged from 0.19-0.34 μg g -1 for Cd and 1.02-1.91 μg g -1 for Pb.São Paulo State University - Unesp Analytical Chemistry Department, P.O. Box 355, 14801-970 Araraquara - SPAlfenas Federal University UNIFAL-MG Institute of Science and Technology, 37715-400 Poços de caldas - MGSão Paulo State University - Unesp Analytical Chemistry Department, P.O. Box 355, 14801-970 Araraquara - SPUniversidade Estadual Paulista (UNESP)Institute of Science and TechnologyFortunato, Felipe Manfroi [UNESP]Neto, José Anchieta Gomes [UNESP]Freschi, Gian Paulo Giovanni2022-04-29T05:24:25Z2022-04-29T05:24:25Z2012-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article138-142Atomic Spectroscopy, v. 33, n. 4, p. 138-142, 2012.0195-5373http://hdl.handle.net/11449/2269902-s2.0-84867251522Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAtomic Spectroscopyinfo:eu-repo/semantics/openAccess2022-04-29T05:24:25Zoai:repositorio.unesp.br:11449/226990Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:35:45.982294Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
title |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
spellingShingle |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling Fortunato, Felipe Manfroi [UNESP] |
title_short |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
title_full |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
title_fullStr |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
title_full_unstemmed |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
title_sort |
Simultaneous determination of cadmium and lead in medicinal plants using graphite furnace atomic absorption spectrometry and direct slurry sampling |
author |
Fortunato, Felipe Manfroi [UNESP] |
author_facet |
Fortunato, Felipe Manfroi [UNESP] Neto, José Anchieta Gomes [UNESP] Freschi, Gian Paulo Giovanni |
author_role |
author |
author2 |
Neto, José Anchieta Gomes [UNESP] Freschi, Gian Paulo Giovanni |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) Institute of Science and Technology |
dc.contributor.author.fl_str_mv |
Fortunato, Felipe Manfroi [UNESP] Neto, José Anchieta Gomes [UNESP] Freschi, Gian Paulo Giovanni |
description |
A method is proposed for the simultaneous determination Cd and Pb in medicinal plants using direct slurry sampling by GF-AAS. The thermal behavior of analytes was checked in aqueous and slurry media using Ir permanent modifier. The optimized pyrolysis (1000 °C and atomization (2200 °C) temperatures allowed calibration using aqueous standards. For a 20-μL injected volume, the calculated characteristic mass was 1.8 pg for Cd and 59 pg for Pb. The relative standard deviation (n=12) for Cd and Pb was 5.3% and 3-5%, respectively. The limit of detection was 0.12 pg L -1 for Cd and 1.22 μg L -1 for Pb. Accuracy was checked by analyzing the standard reference materials Ginkgo Biloba Leaves, Peach Leaves, and Pine Needles. The results obtained for the analytes were in agreement with the certified values at the 95% confidence level. Ten medicinal plant samples were analyzed and the found concentrations ranged from 0.19-0.34 μg g -1 for Cd and 1.02-1.91 μg g -1 for Pb. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-07-01 2022-04-29T05:24:25Z 2022-04-29T05:24:25Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Atomic Spectroscopy, v. 33, n. 4, p. 138-142, 2012. 0195-5373 http://hdl.handle.net/11449/226990 2-s2.0-84867251522 |
identifier_str_mv |
Atomic Spectroscopy, v. 33, n. 4, p. 138-142, 2012. 0195-5373 2-s2.0-84867251522 |
url |
http://hdl.handle.net/11449/226990 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Atomic Spectroscopy |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
138-142 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129224147468288 |