Resumo: In this work we describe a versatile and very sensitive way for copper quantification by potentiometric stripping analysis using gold electrodes obtained from recordable compact disks (CDs). This new source of electrodes (CDtrodes) shown similar performance to the commercial gold electrodes with superior versatility and lower cost. Recordable CDs contains a highly pure gold film with thickness between 50 and 100 nm and superficial area of ca. 100 cm2. The working electrode developed was used successfully in stationary cell and many experimental parameters have been optimized. For copper, the detection limit attained was 30 ng L-1 (600 s deposition time) with remarkable precision (standard deviation of 1.8 % for 20 repetitive measurements using 25 μg L-1 of copper with 60 s of deposition time). The gold electrode developed was used for analysis of copper in sugar cane spirits and tap water samples. The results were compared with those obtained by atomic absorption spectroscopy.
id UNSP_6fdf42cd62c6a411d271ce9330ab760d
oai_identifier_str oai:repositorio.unesp.br:11449/219244
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSABeveragesCD electrodesCopperGold electrodesPotentiometric stripping analysisSugar cane spiritsTap waterIn this work we describe a versatile and very sensitive way for copper quantification by potentiometric stripping analysis using gold electrodes obtained from recordable compact disks (CDs). This new source of electrodes (CDtrodes) shown similar performance to the commercial gold electrodes with superior versatility and lower cost. Recordable CDs contains a highly pure gold film with thickness between 50 and 100 nm and superficial area of ca. 100 cm2. The working electrode developed was used successfully in stationary cell and many experimental parameters have been optimized. For copper, the detection limit attained was 30 ng L-1 (600 s deposition time) with remarkable precision (standard deviation of 1.8 % for 20 repetitive measurements using 25 μg L-1 of copper with 60 s of deposition time). The gold electrode developed was used for analysis of copper in sugar cane spirits and tap water samples. The results were compared with those obtained by atomic absorption spectroscopy.Instituto de Química Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-900 - São PauloFaculdade de Engenharia de Guaratinguetá UNESP, GuaratinguetáFaculdade de Engenharia de Guaratinguetá UNESP, GuaratinguetáUniversidade de São Paulo (USP)Universidade Estadual Paulista (UNESP)Richter, Eduardo M.Augelli, Márcio A. [UNESP]Magarotto, SusaneAngnes, Lúcio2022-04-28T18:54:32Z2022-04-28T18:54:32Z2001-07-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject760-764http://dx.doi.org/10.1002/1521-4109(200105)13:8/9<760Electroanalysis, v. 13, n. 8-9, p. 760-764, 2001.1040-0397http://hdl.handle.net/11449/21924410.1002/1521-4109(200105)13:8/9<7602-s2.0-0034961041Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengElectroanalysisinfo:eu-repo/semantics/openAccess2022-04-28T18:54:32Zoai:repositorio.unesp.br:11449/219244Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-28T18:54:32Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
title Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
spellingShingle Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
Richter, Eduardo M.
Beverages
CD electrodes
Copper
Gold electrodes
Potentiometric stripping analysis
Sugar cane spirits
Tap water
title_short Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
title_full Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
title_fullStr Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
title_full_unstemmed Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
title_sort Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
author Richter, Eduardo M.
author_facet Richter, Eduardo M.
Augelli, Márcio A. [UNESP]
Magarotto, Susane
Angnes, Lúcio
author_role author
author2 Augelli, Márcio A. [UNESP]
Magarotto, Susane
Angnes, Lúcio
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade de São Paulo (USP)
Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Richter, Eduardo M.
Augelli, Márcio A. [UNESP]
Magarotto, Susane
Angnes, Lúcio
dc.subject.por.fl_str_mv Beverages
CD electrodes
Copper
Gold electrodes
Potentiometric stripping analysis
Sugar cane spirits
Tap water
topic Beverages
CD electrodes
Copper
Gold electrodes
Potentiometric stripping analysis
Sugar cane spirits
Tap water
description In this work we describe a versatile and very sensitive way for copper quantification by potentiometric stripping analysis using gold electrodes obtained from recordable compact disks (CDs). This new source of electrodes (CDtrodes) shown similar performance to the commercial gold electrodes with superior versatility and lower cost. Recordable CDs contains a highly pure gold film with thickness between 50 and 100 nm and superficial area of ca. 100 cm2. The working electrode developed was used successfully in stationary cell and many experimental parameters have been optimized. For copper, the detection limit attained was 30 ng L-1 (600 s deposition time) with remarkable precision (standard deviation of 1.8 % for 20 repetitive measurements using 25 μg L-1 of copper with 60 s of deposition time). The gold electrode developed was used for analysis of copper in sugar cane spirits and tap water samples. The results were compared with those obtained by atomic absorption spectroscopy.
publishDate 2001
dc.date.none.fl_str_mv 2001-07-09
2022-04-28T18:54:32Z
2022-04-28T18:54:32Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1002/1521-4109(200105)13:8/9<760
Electroanalysis, v. 13, n. 8-9, p. 760-764, 2001.
1040-0397
http://hdl.handle.net/11449/219244
10.1002/1521-4109(200105)13:8/9<760
2-s2.0-0034961041
url http://dx.doi.org/10.1002/1521-4109(200105)13:8/9<760
http://hdl.handle.net/11449/219244
identifier_str_mv Electroanalysis, v. 13, n. 8-9, p. 760-764, 2001.
1040-0397
10.1002/1521-4109(200105)13:8/9<760
2-s2.0-0034961041
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Electroanalysis
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 760-764
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803046313796829184