On-site weld quality assessment and qualification for stainless steels tanks
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.26850/1678-4618eqj.v47.3.2022.p55-65 http://hdl.handle.net/11449/242096 |
Resumo: | Stainless steel tanks are frequently degraded by localized corrosion in bioprocess industries. A case study of 2101 duplex stainless steel tank allowed to apply a portable electrochemical microcell system (PassivityScan) for on-site weld inspection and corrosion monitoring from the manufacturing until 12 months of operation. During the tank manufacturing, the double loop electrochemical potentiokinetic reactivation technique was applied to measure the sensitization degree on the welded regions. The manufactured tank was submitted to the passivation treatment to improve the passivation properties and corrosion resistance. On-site cyclic polarization tests were performed and confirmed the increase of passivation level of treated surface. The passivation level was measured again after 12 months of operation and detected a lower passivation level compared to the initial passivated surface, indicating that the passivation treatment lost its effect after that period. Therefore, an acceptance criterion to passivation level was empirically determined. PassivityScan is an advanced device to qualify the welds and the passivated surfaces, and useful for corrosion monitoring and the reliability maintenance. |
id |
UNSP_759b76d5f2440c38172ff356485dba9d |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/242096 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
On-site weld quality assessment and qualification for stainless steels tanks2101 lean duplex stainless steelchemical passivation treatmentcyclic polarizationon-site corrosion testssensitized weldStainless steel tanks are frequently degraded by localized corrosion in bioprocess industries. A case study of 2101 duplex stainless steel tank allowed to apply a portable electrochemical microcell system (PassivityScan) for on-site weld inspection and corrosion monitoring from the manufacturing until 12 months of operation. During the tank manufacturing, the double loop electrochemical potentiokinetic reactivation technique was applied to measure the sensitization degree on the welded regions. The manufactured tank was submitted to the passivation treatment to improve the passivation properties and corrosion resistance. On-site cyclic polarization tests were performed and confirmed the increase of passivation level of treated surface. The passivation level was measured again after 12 months of operation and detected a lower passivation level compared to the initial passivated surface, indicating that the passivation treatment lost its effect after that period. Therefore, an acceptance criterion to passivation level was empirically determined. PassivityScan is an advanced device to qualify the welds and the passivated surfaces, and useful for corrosion monitoring and the reliability maintenance.Soudap Soldas Sanitarias Engineering DepartmentACW Engineering Research & Development DepartmentSao Paulo State University Institute of ChemistrySao Paulo State University Institute of ChemistryEngineering DepartmentResearch & Development DepartmentUniversidade Estadual Paulista (UNESP)Guilherme, Luis HenriqueFugivara, Cecilio Sadao [UNESP]Benedetti, Assis Vicente [UNESP]2023-03-02T08:38:23Z2023-03-02T08:38:23Z2022-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article55-65http://dx.doi.org/10.26850/1678-4618eqj.v47.3.2022.p55-65Ecletica Quimica, v. 47, n. 3, p. 55-65, 2022.1678-46180100-4670http://hdl.handle.net/11449/24209610.26850/1678-4618eqj.v47.3.2022.p55-652-s2.0-85135160621Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengEcletica Quimicainfo:eu-repo/semantics/openAccess2023-03-02T08:38:23Zoai:repositorio.unesp.br:11449/242096Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:11:51.922859Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
On-site weld quality assessment and qualification for stainless steels tanks |
title |
On-site weld quality assessment and qualification for stainless steels tanks |
spellingShingle |
On-site weld quality assessment and qualification for stainless steels tanks Guilherme, Luis Henrique 2101 lean duplex stainless steel chemical passivation treatment cyclic polarization on-site corrosion tests sensitized weld |
title_short |
On-site weld quality assessment and qualification for stainless steels tanks |
title_full |
On-site weld quality assessment and qualification for stainless steels tanks |
title_fullStr |
On-site weld quality assessment and qualification for stainless steels tanks |
title_full_unstemmed |
On-site weld quality assessment and qualification for stainless steels tanks |
title_sort |
On-site weld quality assessment and qualification for stainless steels tanks |
author |
Guilherme, Luis Henrique |
author_facet |
Guilherme, Luis Henrique Fugivara, Cecilio Sadao [UNESP] Benedetti, Assis Vicente [UNESP] |
author_role |
author |
author2 |
Fugivara, Cecilio Sadao [UNESP] Benedetti, Assis Vicente [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Engineering Department Research & Development Department Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Guilherme, Luis Henrique Fugivara, Cecilio Sadao [UNESP] Benedetti, Assis Vicente [UNESP] |
dc.subject.por.fl_str_mv |
2101 lean duplex stainless steel chemical passivation treatment cyclic polarization on-site corrosion tests sensitized weld |
topic |
2101 lean duplex stainless steel chemical passivation treatment cyclic polarization on-site corrosion tests sensitized weld |
description |
Stainless steel tanks are frequently degraded by localized corrosion in bioprocess industries. A case study of 2101 duplex stainless steel tank allowed to apply a portable electrochemical microcell system (PassivityScan) for on-site weld inspection and corrosion monitoring from the manufacturing until 12 months of operation. During the tank manufacturing, the double loop electrochemical potentiokinetic reactivation technique was applied to measure the sensitization degree on the welded regions. The manufactured tank was submitted to the passivation treatment to improve the passivation properties and corrosion resistance. On-site cyclic polarization tests were performed and confirmed the increase of passivation level of treated surface. The passivation level was measured again after 12 months of operation and detected a lower passivation level compared to the initial passivated surface, indicating that the passivation treatment lost its effect after that period. Therefore, an acceptance criterion to passivation level was empirically determined. PassivityScan is an advanced device to qualify the welds and the passivated surfaces, and useful for corrosion monitoring and the reliability maintenance. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-01 2023-03-02T08:38:23Z 2023-03-02T08:38:23Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.26850/1678-4618eqj.v47.3.2022.p55-65 Ecletica Quimica, v. 47, n. 3, p. 55-65, 2022. 1678-4618 0100-4670 http://hdl.handle.net/11449/242096 10.26850/1678-4618eqj.v47.3.2022.p55-65 2-s2.0-85135160621 |
url |
http://dx.doi.org/10.26850/1678-4618eqj.v47.3.2022.p55-65 http://hdl.handle.net/11449/242096 |
identifier_str_mv |
Ecletica Quimica, v. 47, n. 3, p. 55-65, 2022. 1678-4618 0100-4670 10.26850/1678-4618eqj.v47.3.2022.p55-65 2-s2.0-85135160621 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Ecletica Quimica |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
55-65 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129297065443328 |