Resumo: | Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system. © 2013 IEEE. |
id |
UNSP_79d5f530707b3e1a9a0eae04d1771018 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/232224 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Capacity of active power reserve for frequency control enhanced by distributed generatorsactive power reserve for frequency controlConventional generatorscosts minimizationdistributed generatorsUsually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system. © 2013 IEEE.Universidade Estadual Paulista - UNESP, Ilha Solteira - SPUniversidade Estadual Paulista - UNESP, Ilha Solteira - SPUniversidade Estadual Paulista (UNESP)Rueda-Medina, Augusto C. [UNESP]Padilha-Feltrin, Antonio [UNESP]Mantovani, J. R.S. [UNESP]2022-04-29T09:23:53Z2022-04-29T09:23:53Z2013-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjecthttp://dx.doi.org/10.1109/PESMG.2013.6672821IEEE Power and Energy Society General Meeting.1944-99251944-9933http://hdl.handle.net/11449/23222410.1109/PESMG.2013.66728212-s2.0-84893176166Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengIEEE Power and Energy Society General Meetinginfo:eu-repo/semantics/openAccess2024-07-04T19:11:39Zoai:repositorio.unesp.br:11449/232224Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T18:44:04.525774Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Capacity of active power reserve for frequency control enhanced by distributed generators |
title |
Capacity of active power reserve for frequency control enhanced by distributed generators |
spellingShingle |
Capacity of active power reserve for frequency control enhanced by distributed generators Rueda-Medina, Augusto C. [UNESP] active power reserve for frequency control Conventional generators costs minimization distributed generators |
title_short |
Capacity of active power reserve for frequency control enhanced by distributed generators |
title_full |
Capacity of active power reserve for frequency control enhanced by distributed generators |
title_fullStr |
Capacity of active power reserve for frequency control enhanced by distributed generators |
title_full_unstemmed |
Capacity of active power reserve for frequency control enhanced by distributed generators |
title_sort |
Capacity of active power reserve for frequency control enhanced by distributed generators |
author |
Rueda-Medina, Augusto C. [UNESP] |
author_facet |
Rueda-Medina, Augusto C. [UNESP] Padilha-Feltrin, Antonio [UNESP] Mantovani, J. R.S. [UNESP] |
author_role |
author |
author2 |
Padilha-Feltrin, Antonio [UNESP] Mantovani, J. R.S. [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Rueda-Medina, Augusto C. [UNESP] Padilha-Feltrin, Antonio [UNESP] Mantovani, J. R.S. [UNESP] |
dc.subject.por.fl_str_mv |
active power reserve for frequency control Conventional generators costs minimization distributed generators |
topic |
active power reserve for frequency control Conventional generators costs minimization distributed generators |
description |
Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system. © 2013 IEEE. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-12-01 2022-04-29T09:23:53Z 2022-04-29T09:23:53Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1109/PESMG.2013.6672821 IEEE Power and Energy Society General Meeting. 1944-9925 1944-9933 http://hdl.handle.net/11449/232224 10.1109/PESMG.2013.6672821 2-s2.0-84893176166 |
url |
http://dx.doi.org/10.1109/PESMG.2013.6672821 http://hdl.handle.net/11449/232224 |
identifier_str_mv |
IEEE Power and Energy Society General Meeting. 1944-9925 1944-9933 10.1109/PESMG.2013.6672821 2-s2.0-84893176166 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
IEEE Power and Energy Society General Meeting |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128972329844736 |