Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector

Detalhes bibliográficos
Autor(a) principal: Amaral, Marina
Data de Publicação: 2017
Outros Autores: Villefort, Regina F. [UNESP], Melo, Renata Marques [UNESP], Pereira, Gabriel K. R., Zhang, Yu, Valandro, Luiz Felipe, Bottino, Marco Antonio [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.jmbbm.2017.03.002
http://hdl.handle.net/11449/162871
Resumo: Objectives: To determine the fatigue failure loads of three-unit monolithic zirconia fixed dental prosthesis (FDPs) before and after grinding of the gingival areas of connectors with diamond burs. Material and methods: FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue failure loads and standard deviations were obtained using a staircase fatigue method (n=20, 100,000 loading cycles/5Hz). The initial test load was 70% of the mean load-to-fracture (n=3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student's T-test (a <= 0.05). Results: Both the control and ground groups exhibited similar values of load-to-fracture and fatigue failure loads. Neither the surface treatments nor ageing affected the surface roughness of the specimens. Conclusions: The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue failure load of the three-unit monolithic zirconia FDP.
id UNSP_7c7eaa617b9bacd970a70eaba9f085ed
oai_identifier_str oai:repositorio.unesp.br:11449/162871
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connectorFixed prosthodonticsZirconium oxide partially stabilized by yttriumGrindingFatigueObjectives: To determine the fatigue failure loads of three-unit monolithic zirconia fixed dental prosthesis (FDPs) before and after grinding of the gingival areas of connectors with diamond burs. Material and methods: FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue failure loads and standard deviations were obtained using a staircase fatigue method (n=20, 100,000 loading cycles/5Hz). The initial test load was 70% of the mean load-to-fracture (n=3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student's T-test (a <= 0.05). Results: Both the control and ground groups exhibited similar values of load-to-fracture and fatigue failure loads. Neither the surface treatments nor ageing affected the surface roughness of the specimens. Conclusions: The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue failure load of the three-unit monolithic zirconia FDP.National Counsel of Technological and Scientific DevelopmentUnited States National Institutes of Health, National Institute of Dental and Craniofacial ResearchUniv Taubate, Dept Dent, Dent Prosthesis, Taubate, SP, BrazilSao Paulo State Univ, Sch Dent, Post Grad Program Restorat Dent, Prosthet Dent Unit, Sao Jose Dos Campos, SP, BrazilUniv Fed Santa Maria, Sch Dent, Post Grad Program Dent Sci, Prosthet Dent Unit, Santa Maria, RS, BrazilNYU, Coll Dent, Dept Biomat & Biomimet, 433 First Ave, New York, NY USASao Paulo State Univ, Sch Dent, Post Grad Program Restorat Dent, Prosthet Dent Unit, Sao Jose Dos Campos, SP, BrazilNational Counsel of Technological and Scientific Development: CNPQ/PDJ 150931/2014-0United States National Institutes of Health, National Institute of Dental and Craniofacial Research: 2R01 DE017925Elsevier B.V.Univ TaubateUniversidade Estadual Paulista (Unesp)Universidade Federal de Sergipe (UFS)NYUAmaral, MarinaVillefort, Regina F. [UNESP]Melo, Renata Marques [UNESP]Pereira, Gabriel K. R.Zhang, YuValandro, Luiz FelipeBottino, Marco Antonio [UNESP]2018-11-26T17:34:46Z2018-11-26T17:34:46Z2017-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article159-162application/pdfhttp://dx.doi.org/10.1016/j.jmbbm.2017.03.002Journal Of The Mechanical Behavior Of Biomedical Materials. Amsterdam: Elsevier Science Bv, v. 72, p. 159-162, 2017.1751-6161http://hdl.handle.net/11449/16287110.1016/j.jmbbm.2017.03.002WOS:000403123600018WOS000403123600018.pdf9234456003563666Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal Of The Mechanical Behavior Of Biomedical Materials0,958info:eu-repo/semantics/openAccess2023-11-30T06:18:35Zoai:repositorio.unesp.br:11449/162871Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-11-30T06:18:35Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
title Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
spellingShingle Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
Amaral, Marina
Fixed prosthodontics
Zirconium oxide partially stabilized by yttrium
Grinding
Fatigue
title_short Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
title_full Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
title_fullStr Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
title_full_unstemmed Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
title_sort Fatigue failure load of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector
author Amaral, Marina
author_facet Amaral, Marina
Villefort, Regina F. [UNESP]
Melo, Renata Marques [UNESP]
Pereira, Gabriel K. R.
Zhang, Yu
Valandro, Luiz Felipe
Bottino, Marco Antonio [UNESP]
author_role author
author2 Villefort, Regina F. [UNESP]
Melo, Renata Marques [UNESP]
Pereira, Gabriel K. R.
Zhang, Yu
Valandro, Luiz Felipe
Bottino, Marco Antonio [UNESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Univ Taubate
Universidade Estadual Paulista (Unesp)
Universidade Federal de Sergipe (UFS)
NYU
dc.contributor.author.fl_str_mv Amaral, Marina
Villefort, Regina F. [UNESP]
Melo, Renata Marques [UNESP]
Pereira, Gabriel K. R.
Zhang, Yu
Valandro, Luiz Felipe
Bottino, Marco Antonio [UNESP]
dc.subject.por.fl_str_mv Fixed prosthodontics
Zirconium oxide partially stabilized by yttrium
Grinding
Fatigue
topic Fixed prosthodontics
Zirconium oxide partially stabilized by yttrium
Grinding
Fatigue
description Objectives: To determine the fatigue failure loads of three-unit monolithic zirconia fixed dental prosthesis (FDPs) before and after grinding of the gingival areas of connectors with diamond burs. Material and methods: FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue failure loads and standard deviations were obtained using a staircase fatigue method (n=20, 100,000 loading cycles/5Hz). The initial test load was 70% of the mean load-to-fracture (n=3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student's T-test (a <= 0.05). Results: Both the control and ground groups exhibited similar values of load-to-fracture and fatigue failure loads. Neither the surface treatments nor ageing affected the surface roughness of the specimens. Conclusions: The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue failure load of the three-unit monolithic zirconia FDP.
publishDate 2017
dc.date.none.fl_str_mv 2017-08-01
2018-11-26T17:34:46Z
2018-11-26T17:34:46Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.jmbbm.2017.03.002
Journal Of The Mechanical Behavior Of Biomedical Materials. Amsterdam: Elsevier Science Bv, v. 72, p. 159-162, 2017.
1751-6161
http://hdl.handle.net/11449/162871
10.1016/j.jmbbm.2017.03.002
WOS:000403123600018
WOS000403123600018.pdf
9234456003563666
url http://dx.doi.org/10.1016/j.jmbbm.2017.03.002
http://hdl.handle.net/11449/162871
identifier_str_mv Journal Of The Mechanical Behavior Of Biomedical Materials. Amsterdam: Elsevier Science Bv, v. 72, p. 159-162, 2017.
1751-6161
10.1016/j.jmbbm.2017.03.002
WOS:000403123600018
WOS000403123600018.pdf
9234456003563666
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal Of The Mechanical Behavior Of Biomedical Materials
0,958
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 159-162
application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965123966664704