Solubility, porosity, dimensional and volumetric change of endodontic sealers

Detalhes bibliográficos
Autor(a) principal: Torres, Fernanda Ferrari Esteves [UNESP]
Data de Publicação: 2019
Outros Autores: Guerreiro-Tanomaru, Juliane Maria [UNESP], Bosso-Martelo, Roberta, Espir, Camila Galletti [UNESP], Camilleri, Josette, Tanomaru-Filho, Mario [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/0103-6440201902607
http://hdl.handle.net/11449/187919
Resumo: The aim Of this study was to evaluate physical properties Of endodontic sealers (AH Plus, MTA Fillapex and Endofill), by conventional and micro-CT tests. Dimensional stability was evaluated after immersion Of materials in distilled water for 30 days. Solubility and volumetric change were evaluated after 7 and 30 days Of immersion in distilled water. Solubility was evaluated by means Of mass loss and volumetric change was assessed by micro-CT. Porosity was evaluated under a microscope after 7 days Of immersion in distilled water, and by using micro-CT after setting and immersion in distilled water for 7 and 30 days. Statistical analysis was performed by ANOVA and Tukey’s test with 5% significance level. MTA Fillapex presented the highest solubility (p<0.05), showing values above the ISO/ADA recommendations. MTA Fillapex presented higher volumetric and dimensional changes, followed by Endofill and AH Plus (p<0.05). Dimensional stability of the MTA Fillapex and AH Plus did not follow ISO/ADA standards. The highest total porosity was Observed for MTA Fillapex (p<0.05). Endofill had higher total porosity than AH Plus according to microscope evaluation (p<0,05), and both sealers were similar in micro-CT assessment (p>0,05). In conclusion, MTA Fillapex presented higher solubility, dimensional and volumetric change besides porosity compared to the Other evaluated sealers. The assessed physical properties of sealers are related, and the different tests provided complementary data. Micro-CT is a valuable method for assessment Of physical properties Of endodontic materials.
id UNSP_7d63d3e017de45a228ed03d5a59af142
oai_identifier_str oai:repositorio.unesp.br:11449/187919
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Solubility, porosity, dimensional and volumetric change of endodontic sealersEndodonticsPhysicochemical analysisSilicate cementX-ray microtomographyThe aim Of this study was to evaluate physical properties Of endodontic sealers (AH Plus, MTA Fillapex and Endofill), by conventional and micro-CT tests. Dimensional stability was evaluated after immersion Of materials in distilled water for 30 days. Solubility and volumetric change were evaluated after 7 and 30 days Of immersion in distilled water. Solubility was evaluated by means Of mass loss and volumetric change was assessed by micro-CT. Porosity was evaluated under a microscope after 7 days Of immersion in distilled water, and by using micro-CT after setting and immersion in distilled water for 7 and 30 days. Statistical analysis was performed by ANOVA and Tukey’s test with 5% significance level. MTA Fillapex presented the highest solubility (p<0.05), showing values above the ISO/ADA recommendations. MTA Fillapex presented higher volumetric and dimensional changes, followed by Endofill and AH Plus (p<0.05). Dimensional stability of the MTA Fillapex and AH Plus did not follow ISO/ADA standards. The highest total porosity was Observed for MTA Fillapex (p<0.05). Endofill had higher total porosity than AH Plus according to microscope evaluation (p<0,05), and both sealers were similar in micro-CT assessment (p>0,05). In conclusion, MTA Fillapex presented higher solubility, dimensional and volumetric change besides porosity compared to the Other evaluated sealers. The assessed physical properties of sealers are related, and the different tests provided complementary data. Micro-CT is a valuable method for assessment Of physical properties Of endodontic materials.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Department of Restorative Dentistry School of Dentistry UNESP – Universidade Estadual PaulistaDepartment of Dentistry School of Dentistry UFBA – Universidade Federal da BahiaSchool of Dentistry Institute of Clinical Sciences College of Clinical and Medical Sciences University of Birmingham, EdgbastonDepartment of Restorative Dentistry School of Dentistry UNESP – Universidade Estadual PaulistaCAPES: 2014/16510-0FAPESP: 2014/16510-0CAPES: 2015/03437-6FAPESP: 2015/03437-6CAPES: 2016/00321-0FAPESP: 2016/00321-0CAPES: 2017/19049-0FAPESP: 2017/19049-0Universidade Estadual Paulista (Unesp)Universidade Federal da Bahia (UFBA)University of BirminghamTorres, Fernanda Ferrari Esteves [UNESP]Guerreiro-Tanomaru, Juliane Maria [UNESP]Bosso-Martelo, RobertaEspir, Camila Galletti [UNESP]Camilleri, JosetteTanomaru-Filho, Mario [UNESP]2019-10-06T15:51:21Z2019-10-06T15:51:21Z2019-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article368-373application/pdfhttp://dx.doi.org/10.1590/0103-6440201902607Brazilian Dental Journal, v. 30, n. 4, p. 368-373, 2019.1806-47600103-6440http://hdl.handle.net/11449/18791910.1590/0103-6440201902607S0103-644020190004003682-s2.0-85069983308S0103-64402019000400368.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journalinfo:eu-repo/semantics/openAccess2023-10-24T06:05:25Zoai:repositorio.unesp.br:11449/187919Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:47:56.467320Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Solubility, porosity, dimensional and volumetric change of endodontic sealers
title Solubility, porosity, dimensional and volumetric change of endodontic sealers
spellingShingle Solubility, porosity, dimensional and volumetric change of endodontic sealers
Torres, Fernanda Ferrari Esteves [UNESP]
Endodontics
Physicochemical analysis
Silicate cement
X-ray microtomography
title_short Solubility, porosity, dimensional and volumetric change of endodontic sealers
title_full Solubility, porosity, dimensional and volumetric change of endodontic sealers
title_fullStr Solubility, porosity, dimensional and volumetric change of endodontic sealers
title_full_unstemmed Solubility, porosity, dimensional and volumetric change of endodontic sealers
title_sort Solubility, porosity, dimensional and volumetric change of endodontic sealers
author Torres, Fernanda Ferrari Esteves [UNESP]
author_facet Torres, Fernanda Ferrari Esteves [UNESP]
Guerreiro-Tanomaru, Juliane Maria [UNESP]
Bosso-Martelo, Roberta
Espir, Camila Galletti [UNESP]
Camilleri, Josette
Tanomaru-Filho, Mario [UNESP]
author_role author
author2 Guerreiro-Tanomaru, Juliane Maria [UNESP]
Bosso-Martelo, Roberta
Espir, Camila Galletti [UNESP]
Camilleri, Josette
Tanomaru-Filho, Mario [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade Federal da Bahia (UFBA)
University of Birmingham
dc.contributor.author.fl_str_mv Torres, Fernanda Ferrari Esteves [UNESP]
Guerreiro-Tanomaru, Juliane Maria [UNESP]
Bosso-Martelo, Roberta
Espir, Camila Galletti [UNESP]
Camilleri, Josette
Tanomaru-Filho, Mario [UNESP]
dc.subject.por.fl_str_mv Endodontics
Physicochemical analysis
Silicate cement
X-ray microtomography
topic Endodontics
Physicochemical analysis
Silicate cement
X-ray microtomography
description The aim Of this study was to evaluate physical properties Of endodontic sealers (AH Plus, MTA Fillapex and Endofill), by conventional and micro-CT tests. Dimensional stability was evaluated after immersion Of materials in distilled water for 30 days. Solubility and volumetric change were evaluated after 7 and 30 days Of immersion in distilled water. Solubility was evaluated by means Of mass loss and volumetric change was assessed by micro-CT. Porosity was evaluated under a microscope after 7 days Of immersion in distilled water, and by using micro-CT after setting and immersion in distilled water for 7 and 30 days. Statistical analysis was performed by ANOVA and Tukey’s test with 5% significance level. MTA Fillapex presented the highest solubility (p<0.05), showing values above the ISO/ADA recommendations. MTA Fillapex presented higher volumetric and dimensional changes, followed by Endofill and AH Plus (p<0.05). Dimensional stability of the MTA Fillapex and AH Plus did not follow ISO/ADA standards. The highest total porosity was Observed for MTA Fillapex (p<0.05). Endofill had higher total porosity than AH Plus according to microscope evaluation (p<0,05), and both sealers were similar in micro-CT assessment (p>0,05). In conclusion, MTA Fillapex presented higher solubility, dimensional and volumetric change besides porosity compared to the Other evaluated sealers. The assessed physical properties of sealers are related, and the different tests provided complementary data. Micro-CT is a valuable method for assessment Of physical properties Of endodontic materials.
publishDate 2019
dc.date.none.fl_str_mv 2019-10-06T15:51:21Z
2019-10-06T15:51:21Z
2019-07-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/0103-6440201902607
Brazilian Dental Journal, v. 30, n. 4, p. 368-373, 2019.
1806-4760
0103-6440
http://hdl.handle.net/11449/187919
10.1590/0103-6440201902607
S0103-64402019000400368
2-s2.0-85069983308
S0103-64402019000400368.pdf
url http://dx.doi.org/10.1590/0103-6440201902607
http://hdl.handle.net/11449/187919
identifier_str_mv Brazilian Dental Journal, v. 30, n. 4, p. 368-373, 2019.
1806-4760
0103-6440
10.1590/0103-6440201902607
S0103-64402019000400368
2-s2.0-85069983308
S0103-64402019000400368.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Dental Journal
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 368-373
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128564181073920