Efficiency of occlusal splints on police officers with TMD

Detalhes bibliográficos
Autor(a) principal: Caria, Paulo Henrique Ferreira
Data de Publicação: 2014
Outros Autores: Faria, Reinaldo José A., Faria, Claudia Regina Sgobbi De [UNESP], Croci, Carla Scanavini, Negrão Filho, Rubens [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-32252014000400292&lng=en&nrm=iso&tlng=en
http://hdl.handle.net/11449/127491
Resumo: Aim: To evaluate of the effect of two different occlusal splints on police officers with TMD. Methods: Thirty police officers were selected based on Research Diagnostic Criteria for TMD and on clinical exams. Volunteers (ten per group) were distributed according to occlusal splints: group A - Control, group B - Michigan Occlusal Splint (MOS), and group C - Planas Appliance (PA). Experimental groups were analyzed using a visual analog pain scale (VAPS), subject to a clinical evaluation of temporomandibular joint. Bilateral surface electromyographic activities of anterior and posterior temporal, masseter and suprahyoid muscles were analyzed at rest and during clenching, before and after four weeks using the occlusal splints. Results: The left and right temporal and masseter muscles sensitivity decreased after using both splints. Pain symptoms increased for group A (Control) and decreased for group C. Conclusions: Planas Appliance was more efficient on pain reduction than the Michigan Occlusal Splint.
id UNSP_7fad29ee7d577cfe465620d1e3c03eae
oai_identifier_str oai:repositorio.unesp.br:11449/127491
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Efficiency of occlusal splints on police officers with TMDTemporomandibular joint disordersStress physiologicalElectromyography, masticatory muscles, occlusal splintsAim: To evaluate of the effect of two different occlusal splints on police officers with TMD. Methods: Thirty police officers were selected based on Research Diagnostic Criteria for TMD and on clinical exams. Volunteers (ten per group) were distributed according to occlusal splints: group A - Control, group B - Michigan Occlusal Splint (MOS), and group C - Planas Appliance (PA). Experimental groups were analyzed using a visual analog pain scale (VAPS), subject to a clinical evaluation of temporomandibular joint. Bilateral surface electromyographic activities of anterior and posterior temporal, masseter and suprahyoid muscles were analyzed at rest and during clenching, before and after four weeks using the occlusal splints. Results: The left and right temporal and masseter muscles sensitivity decreased after using both splints. Pain symptoms increased for group A (Control) and decreased for group C. Conclusions: Planas Appliance was more efficient on pain reduction than the Michigan Occlusal Splint.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Universidade Estadual de Campinas Piracicaba Dental School Department of MorphologyUniversidade do Oeste Paulista Dental School Department of Health SciencesUniversidade Estadual Paulista School of Science and Technology Department of PhysiotherapyUniversidade Estadual Paulista School of Science and Technology Department of PhysiotherapyFaculdade de Odontologia de Piracicaba - UNICAMPUniversidade Estadual de Campinas (UNICAMP)Universidade do Oeste PaulistaUniversidade Estadual Paulista (Unesp)Caria, Paulo Henrique FerreiraFaria, Reinaldo José A.Faria, Claudia Regina Sgobbi De [UNESP]Croci, Carla ScanaviniNegrão Filho, Rubens [UNESP]2015-08-26T19:22:33Z2015-08-26T19:22:33Z2014-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article292-296application/pdfhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-32252014000400292&lng=en&nrm=iso&tlng=enBrazilian Journal of Oral Sciences, v. 13, n. 4, p. 292-296, 2014.1677-3225http://hdl.handle.net/11449/12749110.1590/1677-3225v13n4a10S1677-32252014000400292S1677-32252014000400292.pdf786318948618070055537663967409690000-0001-9007-9274SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Journal of Oral Sciences0,131info:eu-repo/semantics/openAccess2024-06-18T18:44:14Zoai:repositorio.unesp.br:11449/127491Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:18:16.574338Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Efficiency of occlusal splints on police officers with TMD
title Efficiency of occlusal splints on police officers with TMD
spellingShingle Efficiency of occlusal splints on police officers with TMD
Caria, Paulo Henrique Ferreira
Temporomandibular joint disorders
Stress physiological
Electromyography, masticatory muscles, occlusal splints
title_short Efficiency of occlusal splints on police officers with TMD
title_full Efficiency of occlusal splints on police officers with TMD
title_fullStr Efficiency of occlusal splints on police officers with TMD
title_full_unstemmed Efficiency of occlusal splints on police officers with TMD
title_sort Efficiency of occlusal splints on police officers with TMD
author Caria, Paulo Henrique Ferreira
author_facet Caria, Paulo Henrique Ferreira
Faria, Reinaldo José A.
Faria, Claudia Regina Sgobbi De [UNESP]
Croci, Carla Scanavini
Negrão Filho, Rubens [UNESP]
author_role author
author2 Faria, Reinaldo José A.
Faria, Claudia Regina Sgobbi De [UNESP]
Croci, Carla Scanavini
Negrão Filho, Rubens [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual de Campinas (UNICAMP)
Universidade do Oeste Paulista
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Caria, Paulo Henrique Ferreira
Faria, Reinaldo José A.
Faria, Claudia Regina Sgobbi De [UNESP]
Croci, Carla Scanavini
Negrão Filho, Rubens [UNESP]
dc.subject.por.fl_str_mv Temporomandibular joint disorders
Stress physiological
Electromyography, masticatory muscles, occlusal splints
topic Temporomandibular joint disorders
Stress physiological
Electromyography, masticatory muscles, occlusal splints
description Aim: To evaluate of the effect of two different occlusal splints on police officers with TMD. Methods: Thirty police officers were selected based on Research Diagnostic Criteria for TMD and on clinical exams. Volunteers (ten per group) were distributed according to occlusal splints: group A - Control, group B - Michigan Occlusal Splint (MOS), and group C - Planas Appliance (PA). Experimental groups were analyzed using a visual analog pain scale (VAPS), subject to a clinical evaluation of temporomandibular joint. Bilateral surface electromyographic activities of anterior and posterior temporal, masseter and suprahyoid muscles were analyzed at rest and during clenching, before and after four weeks using the occlusal splints. Results: The left and right temporal and masseter muscles sensitivity decreased after using both splints. Pain symptoms increased for group A (Control) and decreased for group C. Conclusions: Planas Appliance was more efficient on pain reduction than the Michigan Occlusal Splint.
publishDate 2014
dc.date.none.fl_str_mv 2014-12-01
2015-08-26T19:22:33Z
2015-08-26T19:22:33Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-32252014000400292&lng=en&nrm=iso&tlng=en
Brazilian Journal of Oral Sciences, v. 13, n. 4, p. 292-296, 2014.
1677-3225
http://hdl.handle.net/11449/127491
10.1590/1677-3225v13n4a10
S1677-32252014000400292
S1677-32252014000400292.pdf
7863189486180700
5553766396740969
0000-0001-9007-9274
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-32252014000400292&lng=en&nrm=iso&tlng=en
http://hdl.handle.net/11449/127491
identifier_str_mv Brazilian Journal of Oral Sciences, v. 13, n. 4, p. 292-296, 2014.
1677-3225
10.1590/1677-3225v13n4a10
S1677-32252014000400292
S1677-32252014000400292.pdf
7863189486180700
5553766396740969
0000-0001-9007-9274
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Journal of Oral Sciences
0,131
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 292-296
application/pdf
dc.publisher.none.fl_str_mv Faculdade de Odontologia de Piracicaba - UNICAMP
publisher.none.fl_str_mv Faculdade de Odontologia de Piracicaba - UNICAMP
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129049265963008