Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1007/s10266-021-00633-0 http://hdl.handle.net/11449/229092 |
Resumo: | The aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (μTBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 °C ± 0.1 ºC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to μTBS. Data were analyzed by Student’s t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 ± 0.39) had significantly higher values than FBS (22.33 ± 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of μTBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h). |
id |
UNSP_80971f5549f307f563f579af70d5e590 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/229092 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentinAdhesivesDental bondingDental pulpThe aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (μTBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 °C ± 0.1 ºC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to μTBS. Data were analyzed by Student’s t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 ± 0.39) had significantly higher values than FBS (22.33 ± 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of μTBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h).Anhanguera Faculty of São José dos Campos, SPDepartment of Clinical Sciences Restorative Faculty of Dentistry University of TorontoDepartment of Prosthodontics Federal University of Espírito Santo, ESDepartment Restorative Dentistry Institute of Science and Technology UNESP–Univ Estadual Paulista, SPCenter for Natural and Human Sciences Federal University of ABC, SPDepartamento de Odontologia Restauradora Instituto de Ciência e Tecnologia UNESP–Univ Estadual Paulista Campus de São José dos Campos, Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, SPDepartment Restorative Dentistry Institute of Science and Technology UNESP–Univ Estadual Paulista, SPDepartamento de Odontologia Restauradora Instituto de Ciência e Tecnologia UNESP–Univ Estadual Paulista Campus de São José dos Campos, Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, SPAnhanguera Faculty of São José dos CamposUniversity of TorontoFederal University of Espírito SantoUniversidade Estadual Paulista (UNESP)Federal University of ABCGonçalves, Lucélia LemesDa Silva, Tânia MaraPrakki, AnuradhaBarcellos, Daphne CamaraCaneppele, Taciana Marco Ferraz [UNESP]De Oliveira, Hueder Paulo MoisésGonçalves, Sérgio Eduardo de Paiva [UNESP]2022-04-29T08:30:20Z2022-04-29T08:30:20Z2022-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article62-69http://dx.doi.org/10.1007/s10266-021-00633-0Odontology, v. 110, n. 1, p. 62-69, 2022.1618-12551618-1247http://hdl.handle.net/11449/22909210.1007/s10266-021-00633-02-s2.0-85109252893Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengOdontologyinfo:eu-repo/semantics/openAccess2022-04-29T08:30:20Zoai:repositorio.unesp.br:11449/229092Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T16:06:06.302224Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
title |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
spellingShingle |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin Gonçalves, Lucélia Lemes Adhesives Dental bonding Dental pulp |
title_short |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
title_full |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
title_fullStr |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
title_full_unstemmed |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
title_sort |
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin |
author |
Gonçalves, Lucélia Lemes |
author_facet |
Gonçalves, Lucélia Lemes Da Silva, Tânia Mara Prakki, Anuradha Barcellos, Daphne Camara Caneppele, Taciana Marco Ferraz [UNESP] De Oliveira, Hueder Paulo Moisés Gonçalves, Sérgio Eduardo de Paiva [UNESP] |
author_role |
author |
author2 |
Da Silva, Tânia Mara Prakki, Anuradha Barcellos, Daphne Camara Caneppele, Taciana Marco Ferraz [UNESP] De Oliveira, Hueder Paulo Moisés Gonçalves, Sérgio Eduardo de Paiva [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Anhanguera Faculty of São José dos Campos University of Toronto Federal University of Espírito Santo Universidade Estadual Paulista (UNESP) Federal University of ABC |
dc.contributor.author.fl_str_mv |
Gonçalves, Lucélia Lemes Da Silva, Tânia Mara Prakki, Anuradha Barcellos, Daphne Camara Caneppele, Taciana Marco Ferraz [UNESP] De Oliveira, Hueder Paulo Moisés Gonçalves, Sérgio Eduardo de Paiva [UNESP] |
dc.subject.por.fl_str_mv |
Adhesives Dental bonding Dental pulp |
topic |
Adhesives Dental bonding Dental pulp |
description |
The aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (μTBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 °C ± 0.1 ºC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to μTBS. Data were analyzed by Student’s t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 ± 0.39) had significantly higher values than FBS (22.33 ± 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of μTBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h). |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-04-29T08:30:20Z 2022-04-29T08:30:20Z 2022-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1007/s10266-021-00633-0 Odontology, v. 110, n. 1, p. 62-69, 2022. 1618-1255 1618-1247 http://hdl.handle.net/11449/229092 10.1007/s10266-021-00633-0 2-s2.0-85109252893 |
url |
http://dx.doi.org/10.1007/s10266-021-00633-0 http://hdl.handle.net/11449/229092 |
identifier_str_mv |
Odontology, v. 110, n. 1, p. 62-69, 2022. 1618-1255 1618-1247 10.1007/s10266-021-00633-0 2-s2.0-85109252893 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Odontology |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
62-69 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128607228264448 |