Comparison of two techniques for surgical eyebrow suspension

Detalhes bibliográficos
Autor(a) principal: Sugino, P. [UNESP]
Data de Publicação: 2022
Outros Autores: Meneghim, R. L.F.S. [UNESP], Schellini, S. A. [UNESP]
Tipo de documento: Artigo
Idioma: eng
fra
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.jfo.2022.03.011
http://hdl.handle.net/11449/242065
Resumo: Purpose: Brow ptosis can interfere with blepharoplasty results and can be corrected using several techniques. The present study was performed to compare two techniques for brow suspension, both with concomitant upper eyelid blepharoplasty. Method: A prospective, interventional, randomized study involving 27 female patients was performed to compare the effects of two different techniques of brow suspension: eyebrow suspension with nylon thread (ESN) and internal browpexy fixation (IBF), both combined with upper lid blepharoplasty. Qualitative assessment was carried out using a questionnaire, and quantitative angular measurement analysis of the brow position was performed using digital photographs taken with a Vectra H1 camera before, 60, and 120 days after surgery. The data were transferred to an Excel table and statistically analyzed. Results: ESN was performed in 14 patients and IBF in 13 patients. Both groups were homogeneous in terms of age. The main preoperative complaints were excess skin on the upper eyelid (81.4%) and reduced visual field (59.2%) in both groups. Most of the patients expected aesthetic improvement, and the surgical results were considered satisfactory for all of them. There was no significant difference between ESN and IBF in the quantitative evaluation of eyebrow position. Conclusion: Both ESN and IBF resulted in a high degree of patient satisfaction. Both techniques provided similar brow suspension, emphasizing that IBF is technically easier to perform and produces less scarring.
id UNSP_8e9134421eac0b3340dd2e7948a6f476
oai_identifier_str oai:repositorio.unesp.br:11449/242065
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Comparison of two techniques for surgical eyebrow suspensionComparaison de deux techniques de suspension chirurgicale des sourcilsBrow ptosisBrow suspension with nylon threadInternal browpexyQualitative analysisQuantitative assessmentPurpose: Brow ptosis can interfere with blepharoplasty results and can be corrected using several techniques. The present study was performed to compare two techniques for brow suspension, both with concomitant upper eyelid blepharoplasty. Method: A prospective, interventional, randomized study involving 27 female patients was performed to compare the effects of two different techniques of brow suspension: eyebrow suspension with nylon thread (ESN) and internal browpexy fixation (IBF), both combined with upper lid blepharoplasty. Qualitative assessment was carried out using a questionnaire, and quantitative angular measurement analysis of the brow position was performed using digital photographs taken with a Vectra H1 camera before, 60, and 120 days after surgery. The data were transferred to an Excel table and statistically analyzed. Results: ESN was performed in 14 patients and IBF in 13 patients. Both groups were homogeneous in terms of age. The main preoperative complaints were excess skin on the upper eyelid (81.4%) and reduced visual field (59.2%) in both groups. Most of the patients expected aesthetic improvement, and the surgical results were considered satisfactory for all of them. There was no significant difference between ESN and IBF in the quantitative evaluation of eyebrow position. Conclusion: Both ESN and IBF resulted in a high degree of patient satisfaction. Both techniques provided similar brow suspension, emphasizing that IBF is technically easier to perform and produces less scarring.Medical School State University of Sao Paulo – UNESP, Sao Paulo StateMedical School State University of Sao Paulo – UNESP, Sao Paulo StateUniversidade Estadual Paulista (UNESP)Sugino, P. [UNESP]Meneghim, R. L.F.S. [UNESP]Schellini, S. A. [UNESP]2023-03-02T08:36:59Z2023-03-02T08:36:59Z2022-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article741-747http://dx.doi.org/10.1016/j.jfo.2022.03.011Journal Francais d'Ophtalmologie, v. 45, n. 7, p. 741-747, 2022.0181-5512http://hdl.handle.net/11449/24206510.1016/j.jfo.2022.03.0112-s2.0-85134603659Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengfraJournal Francais d'Ophtalmologieinfo:eu-repo/semantics/openAccess2024-08-16T18:43:35Zoai:repositorio.unesp.br:11449/242065Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-16T18:43:35Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Comparison of two techniques for surgical eyebrow suspension
Comparaison de deux techniques de suspension chirurgicale des sourcils
title Comparison of two techniques for surgical eyebrow suspension
spellingShingle Comparison of two techniques for surgical eyebrow suspension
Sugino, P. [UNESP]
Brow ptosis
Brow suspension with nylon thread
Internal browpexy
Qualitative analysis
Quantitative assessment
title_short Comparison of two techniques for surgical eyebrow suspension
title_full Comparison of two techniques for surgical eyebrow suspension
title_fullStr Comparison of two techniques for surgical eyebrow suspension
title_full_unstemmed Comparison of two techniques for surgical eyebrow suspension
title_sort Comparison of two techniques for surgical eyebrow suspension
author Sugino, P. [UNESP]
author_facet Sugino, P. [UNESP]
Meneghim, R. L.F.S. [UNESP]
Schellini, S. A. [UNESP]
author_role author
author2 Meneghim, R. L.F.S. [UNESP]
Schellini, S. A. [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Sugino, P. [UNESP]
Meneghim, R. L.F.S. [UNESP]
Schellini, S. A. [UNESP]
dc.subject.por.fl_str_mv Brow ptosis
Brow suspension with nylon thread
Internal browpexy
Qualitative analysis
Quantitative assessment
topic Brow ptosis
Brow suspension with nylon thread
Internal browpexy
Qualitative analysis
Quantitative assessment
description Purpose: Brow ptosis can interfere with blepharoplasty results and can be corrected using several techniques. The present study was performed to compare two techniques for brow suspension, both with concomitant upper eyelid blepharoplasty. Method: A prospective, interventional, randomized study involving 27 female patients was performed to compare the effects of two different techniques of brow suspension: eyebrow suspension with nylon thread (ESN) and internal browpexy fixation (IBF), both combined with upper lid blepharoplasty. Qualitative assessment was carried out using a questionnaire, and quantitative angular measurement analysis of the brow position was performed using digital photographs taken with a Vectra H1 camera before, 60, and 120 days after surgery. The data were transferred to an Excel table and statistically analyzed. Results: ESN was performed in 14 patients and IBF in 13 patients. Both groups were homogeneous in terms of age. The main preoperative complaints were excess skin on the upper eyelid (81.4%) and reduced visual field (59.2%) in both groups. Most of the patients expected aesthetic improvement, and the surgical results were considered satisfactory for all of them. There was no significant difference between ESN and IBF in the quantitative evaluation of eyebrow position. Conclusion: Both ESN and IBF resulted in a high degree of patient satisfaction. Both techniques provided similar brow suspension, emphasizing that IBF is technically easier to perform and produces less scarring.
publishDate 2022
dc.date.none.fl_str_mv 2022-09-01
2023-03-02T08:36:59Z
2023-03-02T08:36:59Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.jfo.2022.03.011
Journal Francais d'Ophtalmologie, v. 45, n. 7, p. 741-747, 2022.
0181-5512
http://hdl.handle.net/11449/242065
10.1016/j.jfo.2022.03.011
2-s2.0-85134603659
url http://dx.doi.org/10.1016/j.jfo.2022.03.011
http://hdl.handle.net/11449/242065
identifier_str_mv Journal Francais d'Ophtalmologie, v. 45, n. 7, p. 741-747, 2022.
0181-5512
10.1016/j.jfo.2022.03.011
2-s2.0-85134603659
dc.language.iso.fl_str_mv eng
fra
language eng
fra
dc.relation.none.fl_str_mv Journal Francais d'Ophtalmologie
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 741-747
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128113639424000