3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1109/COBEP.2011.6085206 http://hdl.handle.net/11449/73092 |
Resumo: | The Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral connection is necessary, including Active Power Filter applications. This topology presents advantages regarding the VSI DC link and capacitance, which make it useful for high power devices. Theory, implementation and simulations are also discussed in this paper. © 2011 IEEE. |
id |
UNSP_91e1bfe3a983f114440ccb3b69cf35a5 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/73092 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
3-D Space Vector PWM implementation for Four-Leg Voltage Source InverterSpace vector pulse width modulationVoltage Source Inverters3-D spaceActive power FilterDC linksFour-legFour-leg voltage sourcesHigh-power devicesSpace vector PWMViable solutionsActive filtersDC power transmissionPower electronicsVector spacesPulse width modulationThe Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral connection is necessary, including Active Power Filter applications. This topology presents advantages regarding the VSI DC link and capacitance, which make it useful for high power devices. Theory, implementation and simulations are also discussed in this paper. © 2011 IEEE.Department of Energy Control and Systems (DSCE-FEEC) UNICAMP (University of Campinas), Campinas, SPDepartment of Power Systems (DSEE-FEEC) UNICAMP, University of Campinas, Campinas, SPGroup of Automation and Integrated Systems (GASI) UNESP, Sorocaba, SPGroup of Automation and Integrated Systems (GASI) UNESP, Sorocaba, SPUniversidade Estadual de Campinas (UNICAMP)Universidade Estadual Paulista (Unesp)Ota, Joao I.Y.Villalva, Marcelo G. [UNESP]Sato, FujioRuppert, Ernesto2014-05-27T11:26:20Z2014-05-27T11:26:20Z2011-12-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject79-86http://dx.doi.org/10.1109/COBEP.2011.6085206COBEP 2011 - 11th Brazilian Power Electronics Conference, p. 79-86.http://hdl.handle.net/11449/7309210.1109/COBEP.2011.60852062-s2.0-84255169812Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengCOBEP 2011 - 11th Brazilian Power Electronics Conferenceinfo:eu-repo/semantics/openAccess2021-10-23T21:37:46Zoai:repositorio.unesp.br:11449/73092Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-06T00:14:11.574436Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
title |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
spellingShingle |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter Ota, Joao I.Y. Space vector pulse width modulation Voltage Source Inverters 3-D space Active power Filter DC links Four-leg Four-leg voltage sources High-power devices Space vector PWM Viable solutions Active filters DC power transmission Power electronics Vector spaces Pulse width modulation |
title_short |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
title_full |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
title_fullStr |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
title_full_unstemmed |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
title_sort |
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter |
author |
Ota, Joao I.Y. |
author_facet |
Ota, Joao I.Y. Villalva, Marcelo G. [UNESP] Sato, Fujio Ruppert, Ernesto |
author_role |
author |
author2 |
Villalva, Marcelo G. [UNESP] Sato, Fujio Ruppert, Ernesto |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual de Campinas (UNICAMP) Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Ota, Joao I.Y. Villalva, Marcelo G. [UNESP] Sato, Fujio Ruppert, Ernesto |
dc.subject.por.fl_str_mv |
Space vector pulse width modulation Voltage Source Inverters 3-D space Active power Filter DC links Four-leg Four-leg voltage sources High-power devices Space vector PWM Viable solutions Active filters DC power transmission Power electronics Vector spaces Pulse width modulation |
topic |
Space vector pulse width modulation Voltage Source Inverters 3-D space Active power Filter DC links Four-leg Four-leg voltage sources High-power devices Space vector PWM Viable solutions Active filters DC power transmission Power electronics Vector spaces Pulse width modulation |
description |
The Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral connection is necessary, including Active Power Filter applications. This topology presents advantages regarding the VSI DC link and capacitance, which make it useful for high power devices. Theory, implementation and simulations are also discussed in this paper. © 2011 IEEE. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-12-28 2014-05-27T11:26:20Z 2014-05-27T11:26:20Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1109/COBEP.2011.6085206 COBEP 2011 - 11th Brazilian Power Electronics Conference, p. 79-86. http://hdl.handle.net/11449/73092 10.1109/COBEP.2011.6085206 2-s2.0-84255169812 |
url |
http://dx.doi.org/10.1109/COBEP.2011.6085206 http://hdl.handle.net/11449/73092 |
identifier_str_mv |
COBEP 2011 - 11th Brazilian Power Electronics Conference, p. 79-86. 10.1109/COBEP.2011.6085206 2-s2.0-84255169812 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
COBEP 2011 - 11th Brazilian Power Electronics Conference |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
79-86 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129598130487296 |