Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1007/s00784-018-2439-5 http://hdl.handle.net/11449/176205 |
Resumo: | Objectives: The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. Methods: The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. Results: The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. Conclusions: The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Clinical significance: Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment. |
id |
UNSP_942e79dcc4d3fb44ce9508ec39afaa81 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/176205 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatmentDental bleachingEnamel microabrasionTheraMon microsensorWearing-timesObjectives: The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. Methods: The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. Results: The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. Conclusions: The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Clinical significance: Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment.Department of Restorative Dentistry and Prosthodontics Ingá University Center - UNINGÁ, 317 PR RoadDepartment of Restorative Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio StDepartment of Orthodontics and Orofacial Orthopedics Eberhard Karls University, Osiamderstr. 2-8Department of Conservative Dentistry School of Dentistry Federal University of Rio Grande do Sul - UFRGS, 110 Paulo Gama AvDepartment of Pediatrics and Social Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio StDepartment of Restorative Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio StDepartment of Pediatrics and Social Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio StIngá University Center - UNINGÁUniversidade Estadual Paulista (Unesp)Eberhard Karls UniversityFederal University of Rio Grande do Sul - UFRGSSundfeld, DanielPavani, Caio Cesar [UNESP]Schott, Timm CorneliusMachado, Lucas SilveiraPini, Núbia Inocêncya PavesiBertoz, André Pinheiro De Magalhães [UNESP]Sundfeld, Renato Herman [UNESP]2018-12-11T17:19:35Z2018-12-11T17:19:35Z2018-04-20info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1-6application/pdfhttp://dx.doi.org/10.1007/s00784-018-2439-5Clinical Oral Investigations, p. 1-6.1436-37711432-6981http://hdl.handle.net/11449/17620510.1007/s00784-018-2439-52-s2.0-850457235882-s2.0-85045723588.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengClinical Oral Investigations0,9860,986info:eu-repo/semantics/openAccess2024-09-19T18:31:44Zoai:repositorio.unesp.br:11449/176205Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-19T18:31:44Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
title |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
spellingShingle |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment Sundfeld, Daniel Dental bleaching Enamel microabrasion TheraMon microsensor Wearing-times |
title_short |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
title_full |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
title_fullStr |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
title_full_unstemmed |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
title_sort |
Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment |
author |
Sundfeld, Daniel |
author_facet |
Sundfeld, Daniel Pavani, Caio Cesar [UNESP] Schott, Timm Cornelius Machado, Lucas Silveira Pini, Núbia Inocêncya Pavesi Bertoz, André Pinheiro De Magalhães [UNESP] Sundfeld, Renato Herman [UNESP] |
author_role |
author |
author2 |
Pavani, Caio Cesar [UNESP] Schott, Timm Cornelius Machado, Lucas Silveira Pini, Núbia Inocêncya Pavesi Bertoz, André Pinheiro De Magalhães [UNESP] Sundfeld, Renato Herman [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Ingá University Center - UNINGÁ Universidade Estadual Paulista (Unesp) Eberhard Karls University Federal University of Rio Grande do Sul - UFRGS |
dc.contributor.author.fl_str_mv |
Sundfeld, Daniel Pavani, Caio Cesar [UNESP] Schott, Timm Cornelius Machado, Lucas Silveira Pini, Núbia Inocêncya Pavesi Bertoz, André Pinheiro De Magalhães [UNESP] Sundfeld, Renato Herman [UNESP] |
dc.subject.por.fl_str_mv |
Dental bleaching Enamel microabrasion TheraMon microsensor Wearing-times |
topic |
Dental bleaching Enamel microabrasion TheraMon microsensor Wearing-times |
description |
Objectives: The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. Methods: The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. Results: The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. Conclusions: The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Clinical significance: Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-12-11T17:19:35Z 2018-12-11T17:19:35Z 2018-04-20 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1007/s00784-018-2439-5 Clinical Oral Investigations, p. 1-6. 1436-3771 1432-6981 http://hdl.handle.net/11449/176205 10.1007/s00784-018-2439-5 2-s2.0-85045723588 2-s2.0-85045723588.pdf |
url |
http://dx.doi.org/10.1007/s00784-018-2439-5 http://hdl.handle.net/11449/176205 |
identifier_str_mv |
Clinical Oral Investigations, p. 1-6. 1436-3771 1432-6981 10.1007/s00784-018-2439-5 2-s2.0-85045723588 2-s2.0-85045723588.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Clinical Oral Investigations 0,986 0,986 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1-6 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546470442270720 |