Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips

Detalhes bibliográficos
Autor(a) principal: Mollica, Fernanda Brandao [UNESP]
Data de Publicação: 2008
Outros Autores: Camargo, Fernanda Pelogia [UNESP], Zamboni, Sandra Costa [UNESP], Braga Pereira, Sarina Maciel [UNESP], Teixeira, Symone Cristina [UNESP], Nogueira Junior, Lafayette [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S1678-77572008000300009
http://hdl.handle.net/11449/22788
Resumo: The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.
id UNSP_9b16937176d309ea904b39face033ab5
oai_identifier_str oai:repositorio.unesp.br:11449/22788
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tipsdental pulpdental cavity preparationThe aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.São Paulo State Univ, Dept Restorat Dent, São Paulo, BrazilSão Paulo State Univ, Dept Dent Mat & Prosthodont, São Paulo, BrazilSão Paulo State Univ, Dept Pediat Dent, São Paulo, BrazilSão Paulo State Univ, Dept Restorat Dent, São Paulo, BrazilSão Paulo State Univ, Dept Dent Mat & Prosthodont, São Paulo, BrazilSão Paulo State Univ, Dept Pediat Dent, São Paulo, BrazilUniversidade de São Paulo (USP), Faculdade de Odontologia de BauruUniversidade Estadual Paulista (Unesp)Mollica, Fernanda Brandao [UNESP]Camargo, Fernanda Pelogia [UNESP]Zamboni, Sandra Costa [UNESP]Braga Pereira, Sarina Maciel [UNESP]Teixeira, Symone Cristina [UNESP]Nogueira Junior, Lafayette [UNESP]2014-05-20T14:04:59Z2014-05-20T14:04:59Z2008-05-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article209-213application/pdfhttp://dx.doi.org/10.1590/S1678-77572008000300009Journal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 16, n. 3, p. 209-213, 2008.1678-7757http://hdl.handle.net/11449/22788S1678-77572008000300009WOS:000256795900009S1678-77572008000300009.pdf17284627535167517376974788169619Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Applied Oral Science1.7090,645info:eu-repo/semantics/openAccess2023-12-21T06:19:32Zoai:repositorio.unesp.br:11449/22788Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-12-21T06:19:32Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
title Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
spellingShingle Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
Mollica, Fernanda Brandao [UNESP]
dental pulp
dental cavity preparation
title_short Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
title_full Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
title_fullStr Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
title_full_unstemmed Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
title_sort Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips
author Mollica, Fernanda Brandao [UNESP]
author_facet Mollica, Fernanda Brandao [UNESP]
Camargo, Fernanda Pelogia [UNESP]
Zamboni, Sandra Costa [UNESP]
Braga Pereira, Sarina Maciel [UNESP]
Teixeira, Symone Cristina [UNESP]
Nogueira Junior, Lafayette [UNESP]
author_role author
author2 Camargo, Fernanda Pelogia [UNESP]
Zamboni, Sandra Costa [UNESP]
Braga Pereira, Sarina Maciel [UNESP]
Teixeira, Symone Cristina [UNESP]
Nogueira Junior, Lafayette [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Mollica, Fernanda Brandao [UNESP]
Camargo, Fernanda Pelogia [UNESP]
Zamboni, Sandra Costa [UNESP]
Braga Pereira, Sarina Maciel [UNESP]
Teixeira, Symone Cristina [UNESP]
Nogueira Junior, Lafayette [UNESP]
dc.subject.por.fl_str_mv dental pulp
dental cavity preparation
topic dental pulp
dental cavity preparation
description The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.
publishDate 2008
dc.date.none.fl_str_mv 2008-05-01
2014-05-20T14:04:59Z
2014-05-20T14:04:59Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1678-77572008000300009
Journal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 16, n. 3, p. 209-213, 2008.
1678-7757
http://hdl.handle.net/11449/22788
S1678-77572008000300009
WOS:000256795900009
S1678-77572008000300009.pdf
1728462753516751
7376974788169619
url http://dx.doi.org/10.1590/S1678-77572008000300009
http://hdl.handle.net/11449/22788
identifier_str_mv Journal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 16, n. 3, p. 209-213, 2008.
1678-7757
S1678-77572008000300009
WOS:000256795900009
S1678-77572008000300009.pdf
1728462753516751
7376974788169619
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Applied Oral Science
1.709
0,645
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 209-213
application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965355273093120