Resumo: | The electrolytic treatment of a real industrial effl uent and simulated wastewater containing the 1,2-dihydro- 2,2,4-trimethylquinoleyn compound (Naugard Q®) had been investigated in order to improve the wastewater biodegradability. The electrolysis was carried out in a batch electrolytic cell using 70TiO2 /30RuO2 electrodes (DSA® anode). After electrochemical treatment, wastewaters were evaluated in terms of Naugard Q® concentration, UV-visible spectrophotometry and biodegradation. Further analyses were conducted in simulated wastewater by gas chromatography and the biodegradation process was monitored using respirometric fl asks. Both real effl uent and simulated wastewater presented a decrease in Naugard Q® concentration. The simulated wastewater electrolytic treatment provided concentration reduction of Naugard Q® about 52.04% after 60 min, whereas real effl uent concentration was reduced by 62.60% after 40 minutes. Furthermore, UV-visible spectra and gas chromatograms presented signifi cant alterations in molecular structure of the compound. After 30 min electrolysis, an increase in simulated wastewater biodegradation was observed. In real effl uent, the biodegradation response was faster, as more CO2 was produced in assays that underwent 10 and 25 minutes of electrolytic treatment. This result is probably related to modifi cations in Naugard Q® molecular structure. It was concluded that the electrolytic treatment followed by bioremediation could be an alternate treatment to degrade this compound. |
id |
UNSP_9dc3b420310f2b5e5d81ac4ab0e63150 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/140359 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric methodNaugard Q®Industrial effluentDSA electrodesBiodegradationWater treatmentThe electrolytic treatment of a real industrial effl uent and simulated wastewater containing the 1,2-dihydro- 2,2,4-trimethylquinoleyn compound (Naugard Q®) had been investigated in order to improve the wastewater biodegradability. The electrolysis was carried out in a batch electrolytic cell using 70TiO2 /30RuO2 electrodes (DSA® anode). After electrochemical treatment, wastewaters were evaluated in terms of Naugard Q® concentration, UV-visible spectrophotometry and biodegradation. Further analyses were conducted in simulated wastewater by gas chromatography and the biodegradation process was monitored using respirometric fl asks. Both real effl uent and simulated wastewater presented a decrease in Naugard Q® concentration. The simulated wastewater electrolytic treatment provided concentration reduction of Naugard Q® about 52.04% after 60 min, whereas real effl uent concentration was reduced by 62.60% after 40 minutes. Furthermore, UV-visible spectra and gas chromatograms presented signifi cant alterations in molecular structure of the compound. After 30 min electrolysis, an increase in simulated wastewater biodegradation was observed. In real effl uent, the biodegradation response was faster, as more CO2 was produced in assays that underwent 10 and 25 minutes of electrolytic treatment. This result is probably related to modifi cations in Naugard Q® molecular structure. It was concluded that the electrolytic treatment followed by bioremediation could be an alternate treatment to degrade this compound.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Universidade Estadual Paulista, Faculdade de Tecnologia de LimeiraUniversidade Estadual Paulista, Departamento de Bioquímica e Microbiologia, Instituto de Biociências de Rio ClaroUniversidade Estadual Paulista, Departamento de Estatística, Matemática Aplicada e Computação, Instituto de Geociências e Ciências Exatas de Rio ClaroUniversidade Estadual Paulista (Unesp)Universidade Estadual de Campinas (UNICAMP)Inazaki, Thelma Helena [UNESP]Moraes, Peterson Bueno deRegis, Gisela [UNESP]Lopes, Paulo Renato Matos [UNESP]Montagnolli, Renato Nallin [UNESP]Pião, Antonio Carlos Simões [UNESP]Bidoia, Ederio Dino [UNESP]2016-07-07T12:33:28Z2016-07-07T12:33:28Z2010info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1-5application/pdfhttp://dx.doi.org/10.4172/2157-7587.1000101Journal of Waste Water Treatment & Analysis, v. 1, n. 1, p. 1-5, 2010.2157-7587http://hdl.handle.net/11449/14035910.4172/2157-7587.1000101ISSN2157-7587-2010-01-01-01-05.pdf922034858356004308544031487097750000-0001-7040-19830000-0003-4886-5292Currículo Lattesreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Waste Water Treatment & Analysisinfo:eu-repo/semantics/openAccess2023-12-17T06:19:50Zoai:repositorio.unesp.br:11449/140359Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:34:05.461376Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
title |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
spellingShingle |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method Inazaki, Thelma Helena [UNESP] Naugard Q® Industrial effluent DSA electrodes Biodegradation Water treatment |
title_short |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
title_full |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
title_fullStr |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
title_full_unstemmed |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
title_sort |
Wastewater containing 1,2-Dihydro-2,2,4-Trimethylquinoleyn treated by electrolysis and respirometric method |
author |
Inazaki, Thelma Helena [UNESP] |
author_facet |
Inazaki, Thelma Helena [UNESP] Moraes, Peterson Bueno de Regis, Gisela [UNESP] Lopes, Paulo Renato Matos [UNESP] Montagnolli, Renato Nallin [UNESP] Pião, Antonio Carlos Simões [UNESP] Bidoia, Ederio Dino [UNESP] |
author_role |
author |
author2 |
Moraes, Peterson Bueno de Regis, Gisela [UNESP] Lopes, Paulo Renato Matos [UNESP] Montagnolli, Renato Nallin [UNESP] Pião, Antonio Carlos Simões [UNESP] Bidoia, Ederio Dino [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade Estadual de Campinas (UNICAMP) |
dc.contributor.author.fl_str_mv |
Inazaki, Thelma Helena [UNESP] Moraes, Peterson Bueno de Regis, Gisela [UNESP] Lopes, Paulo Renato Matos [UNESP] Montagnolli, Renato Nallin [UNESP] Pião, Antonio Carlos Simões [UNESP] Bidoia, Ederio Dino [UNESP] |
dc.subject.por.fl_str_mv |
Naugard Q® Industrial effluent DSA electrodes Biodegradation Water treatment |
topic |
Naugard Q® Industrial effluent DSA electrodes Biodegradation Water treatment |
description |
The electrolytic treatment of a real industrial effl uent and simulated wastewater containing the 1,2-dihydro- 2,2,4-trimethylquinoleyn compound (Naugard Q®) had been investigated in order to improve the wastewater biodegradability. The electrolysis was carried out in a batch electrolytic cell using 70TiO2 /30RuO2 electrodes (DSA® anode). After electrochemical treatment, wastewaters were evaluated in terms of Naugard Q® concentration, UV-visible spectrophotometry and biodegradation. Further analyses were conducted in simulated wastewater by gas chromatography and the biodegradation process was monitored using respirometric fl asks. Both real effl uent and simulated wastewater presented a decrease in Naugard Q® concentration. The simulated wastewater electrolytic treatment provided concentration reduction of Naugard Q® about 52.04% after 60 min, whereas real effl uent concentration was reduced by 62.60% after 40 minutes. Furthermore, UV-visible spectra and gas chromatograms presented signifi cant alterations in molecular structure of the compound. After 30 min electrolysis, an increase in simulated wastewater biodegradation was observed. In real effl uent, the biodegradation response was faster, as more CO2 was produced in assays that underwent 10 and 25 minutes of electrolytic treatment. This result is probably related to modifi cations in Naugard Q® molecular structure. It was concluded that the electrolytic treatment followed by bioremediation could be an alternate treatment to degrade this compound. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010 2016-07-07T12:33:28Z 2016-07-07T12:33:28Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.4172/2157-7587.1000101 Journal of Waste Water Treatment & Analysis, v. 1, n. 1, p. 1-5, 2010. 2157-7587 http://hdl.handle.net/11449/140359 10.4172/2157-7587.1000101 ISSN2157-7587-2010-01-01-01-05.pdf 9220348583560043 0854403148709775 0000-0001-7040-1983 0000-0003-4886-5292 |
url |
http://dx.doi.org/10.4172/2157-7587.1000101 http://hdl.handle.net/11449/140359 |
identifier_str_mv |
Journal of Waste Water Treatment & Analysis, v. 1, n. 1, p. 1-5, 2010. 2157-7587 10.4172/2157-7587.1000101 ISSN2157-7587-2010-01-01-01-05.pdf 9220348583560043 0854403148709775 0000-0001-7040-1983 0000-0003-4886-5292 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Waste Water Treatment & Analysis |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1-5 application/pdf |
dc.source.none.fl_str_mv |
Currículo Lattes reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129220363157504 |