Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao
Autor(a) principal: | |
---|---|
Data de Publicação: | 2000 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | spa |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://www.sba.org.br/revista/ http://hdl.handle.net/11449/66242 |
Resumo: | Network reconfiguration in distribution systems can be carried out by changing the status of sectionalizing switches and it is usually done for loss minimization and load balancing. In this paper it is presented an heuristic algorithm that accomplishes network reconfiguration for operation planning in order to obtain a configuration set whose configurations have the smallest active losses on its feeders. To obtain the configurations, it is used an approached radial load flow method and an heuristic proceeding based on maximum limit of voltage drop on feeders. Results are presented for three hypothetical systems largely known whose data are available in literature and a real system with 135 busses. In addition, it is used a fast and robust load flow which decreases the computational effort. |
id |
UNSP_a2ba6cdc01c8ab3cb29cdd7343e276c1 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/66242 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensaoAlgorithmsElectric lossesElectric network analysisElectric potentialHeuristic methodsVoltage dropSwitching networksNetwork reconfiguration in distribution systems can be carried out by changing the status of sectionalizing switches and it is usually done for loss minimization and load balancing. In this paper it is presented an heuristic algorithm that accomplishes network reconfiguration for operation planning in order to obtain a configuration set whose configurations have the smallest active losses on its feeders. To obtain the configurations, it is used an approached radial load flow method and an heuristic proceeding based on maximum limit of voltage drop on feeders. Results are presented for three hypothetical systems largely known whose data are available in literature and a real system with 135 busses. In addition, it is used a fast and robust load flow which decreases the computational effort.Departamento de Engenharia Elétrica Faculdade de Engenharia de Ilha Solteira FEIS/UNESP, Av. Brasil, 56, 15385-000 Ilha Solteira, SPMECS-Manutenção de Subestaçõe e Usinas Caiuá Serviços de Eletricidade S.A., 19001-970 Presidente Prudente, SPDepartamento de Engenharia Elétrica Faculdade de Engenharia de Ilha Solteira FEIS/UNESP, Av. Brasil, 56, 15385-000 Ilha Solteira, SPUniversidade Estadual Paulista (Unesp)Caiuá Serviços de Eletricidade S.A.Mantovani, José R.S. [UNESP]Casari, FernandoRomero, Rubén A. [UNESP]2014-05-27T11:19:56Z2014-05-27T11:19:56Z2000-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article150-159application/pdfhttp://www.sba.org.br/revista/Controle and Automacao, v. 11, n. 3, p. 150-159, 2000.0103-1759http://hdl.handle.net/11449/662422-s2.0-00342623732-s2.0-0034262373.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPspaControle and Automacaoinfo:eu-repo/semantics/openAccess2024-07-04T19:05:43Zoai:repositorio.unesp.br:11449/66242Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T13:53:23.331602Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
title |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
spellingShingle |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao Mantovani, José R.S. [UNESP] Algorithms Electric losses Electric network analysis Electric potential Heuristic methods Voltage drop Switching networks |
title_short |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
title_full |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
title_fullStr |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
title_full_unstemmed |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
title_sort |
Reconfiguracao de sistemas de distribuicao radiais utilizando o criterio de queda de tensao |
author |
Mantovani, José R.S. [UNESP] |
author_facet |
Mantovani, José R.S. [UNESP] Casari, Fernando Romero, Rubén A. [UNESP] |
author_role |
author |
author2 |
Casari, Fernando Romero, Rubén A. [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Caiuá Serviços de Eletricidade S.A. |
dc.contributor.author.fl_str_mv |
Mantovani, José R.S. [UNESP] Casari, Fernando Romero, Rubén A. [UNESP] |
dc.subject.por.fl_str_mv |
Algorithms Electric losses Electric network analysis Electric potential Heuristic methods Voltage drop Switching networks |
topic |
Algorithms Electric losses Electric network analysis Electric potential Heuristic methods Voltage drop Switching networks |
description |
Network reconfiguration in distribution systems can be carried out by changing the status of sectionalizing switches and it is usually done for loss minimization and load balancing. In this paper it is presented an heuristic algorithm that accomplishes network reconfiguration for operation planning in order to obtain a configuration set whose configurations have the smallest active losses on its feeders. To obtain the configurations, it is used an approached radial load flow method and an heuristic proceeding based on maximum limit of voltage drop on feeders. Results are presented for three hypothetical systems largely known whose data are available in literature and a real system with 135 busses. In addition, it is used a fast and robust load flow which decreases the computational effort. |
publishDate |
2000 |
dc.date.none.fl_str_mv |
2000-09-01 2014-05-27T11:19:56Z 2014-05-27T11:19:56Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.sba.org.br/revista/ Controle and Automacao, v. 11, n. 3, p. 150-159, 2000. 0103-1759 http://hdl.handle.net/11449/66242 2-s2.0-0034262373 2-s2.0-0034262373.pdf |
url |
http://www.sba.org.br/revista/ http://hdl.handle.net/11449/66242 |
identifier_str_mv |
Controle and Automacao, v. 11, n. 3, p. 150-159, 2000. 0103-1759 2-s2.0-0034262373 2-s2.0-0034262373.pdf |
dc.language.iso.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
Controle and Automacao |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
150-159 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128288082624512 |