MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL

Detalhes bibliográficos
Autor(a) principal: Tucci, P. J.F.
Data de Publicação: 1974
Outros Autores: Cicogna, A. C., Spadaro, J.
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/219046
Resumo: The authors describe the working principles of Telco's micromanometer. They discuss its advantages and disadvantages as compared to the conventional pressure measurement techniques and the value of the method when a high fidelity left ventricular pressure is needed. Some disadvantages of the common catheterization technique, due to the liquid column of the system, are pointed out.
id UNSP_a3f97e5eb8206eabfc0ac97f125baae3
oai_identifier_str oai:repositorio.unesp.br:11449/219046
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONALIntracardiac micromanometer. Its principles, advantages and disadvantages in relation to the conventional manometerThe authors describe the working principles of Telco's micromanometer. They discuss its advantages and disadvantages as compared to the conventional pressure measurement techniques and the value of the method when a high fidelity left ventricular pressure is needed. Some disadvantages of the common catheterization technique, due to the liquid column of the system, are pointed out.Unidade Hemodinamica, Dept. Med., Fac. Ci. Med. Biol., Botucatu2022-04-28T18:53:28Z2022-04-28T18:53:28Z1974-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article415-420Arquivos Brasileiros de Cardiologia, v. 27, n. 4, p. 415-420, 1974.0066-782Xhttp://hdl.handle.net/11449/2190462-s2.0-0016301931Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporArquivos Brasileiros de CardiologiaTucci, P. J.F.Cicogna, A. C.Spadaro, J.info:eu-repo/semantics/openAccess2022-04-28T18:53:28Zoai:repositorio.unesp.br:11449/219046Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-28T18:53:28Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
Intracardiac micromanometer. Its principles, advantages and disadvantages in relation to the conventional manometer
title MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
spellingShingle MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
Tucci, P. J.F.
title_short MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
title_full MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
title_fullStr MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
title_full_unstemmed MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
title_sort MICROMANOMETRO INTRACARDIACO. PRINCIPIOS DO METODO, VANTAGENS E DESVANTAGENS EM RELACAO A MANOMETRIA CONVENCIONAL
author Tucci, P. J.F.
author_facet Tucci, P. J.F.
Cicogna, A. C.
Spadaro, J.
author_role author
author2 Cicogna, A. C.
Spadaro, J.
author2_role author
author
dc.contributor.author.fl_str_mv Tucci, P. J.F.
Cicogna, A. C.
Spadaro, J.
description The authors describe the working principles of Telco's micromanometer. They discuss its advantages and disadvantages as compared to the conventional pressure measurement techniques and the value of the method when a high fidelity left ventricular pressure is needed. Some disadvantages of the common catheterization technique, due to the liquid column of the system, are pointed out.
publishDate 1974
dc.date.none.fl_str_mv 1974-01-01
2022-04-28T18:53:28Z
2022-04-28T18:53:28Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv Arquivos Brasileiros de Cardiologia, v. 27, n. 4, p. 415-420, 1974.
0066-782X
http://hdl.handle.net/11449/219046
2-s2.0-0016301931
identifier_str_mv Arquivos Brasileiros de Cardiologia, v. 27, n. 4, p. 415-420, 1974.
0066-782X
2-s2.0-0016301931
url http://hdl.handle.net/11449/219046
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv Arquivos Brasileiros de Cardiologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 415-420
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803047409741201408